The rules should oblige the seller to give the purchaser an operating instrucion of Carrier 42GW, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Carrier 42GW one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Carrier 42GW. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Carrier 42GW should contain:
- informations concerning technical data of Carrier 42GW
- name of the manufacturer and a year of construction of the Carrier 42GW item
- rules of operation, control and maintenance of the Carrier 42GW item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Carrier 42GW alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Carrier 42GW, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Carrier service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Carrier 42GW.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Carrier 42GW item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    42GW • L L O Y D ' S R E G I S T E R Q U A L I T Y A S S U R A N C E I S O 9 0 0 1 INST ALLA TION MANU AL[...]

  • Page 2

    ENGLISH GB - 1 42 GW “Hydronic Global Cassette” Fan Coil Units Contents P a ge Dimensions and weights ........................................................................ 2 T echnical data ........................................................................................ 3 General information ..........................................[...]

  • Page 3

    42 GW GB - 2 Dimensions and weights 42GW 004 008 010 012 016 020 Unit 17.5 19 19 36 38 38 Frame/Grille assembly 333555 813 595 960 298 120 225 280 Ø 150 440 88 160 825 11 2 70 125 825 120 ø150 298 237 52 100 50 160 11 0 90 155 575 158 Ø 70 720 550 515 Ø 25 Ø 25 62 0 Ø 100 150 575 42GW 012 - 016 - 020 kg 42GW 004 - 008 - 010[...]

  • Page 4

    42 GW GB - 3 ENGLISH T able III: T echnical data of electric heaters (if installed) IMPORT ANT : The electric heater must always be factory installed (mod. 42GWE/H...). The use of other eletric heaters is absolutely prohibited. Failure to follow this safety requirement causes unit damage and voids the warranty . T able I: Nominal data • The power[...]

  • Page 5

    42 GW GB - 4 General Information Unit installation Read this instruction manual thoroughly before starting installation. • This unit complies with the low-voltage (EEC/73/23) and electromagnetic compatibility (EEC/ 89/336) directives. • The installation should be carried out by a qualified installer . • Follow all current national safety code[...]

  • Page 6

    GB - 5 42 GW ENGLISH A void... MAX 3 m MAX 3 m MAX. 200 mm ... any obstruction of the unit air intake or supply grilles. ... exposure to direct sunshine, when the unit is operating in the cooling mode; always use shutters or shades. ... positions too close to heating sources which may damage the unit. ... ascending sections of condensate drain pipi[...]

  • Page 7

    42 GW GB - 6 Installation   Prior to installation It is advisable to place the unit as close as possible to the installation site before removing it from the packaging. The grille panel and the control are separately packed for maximum protection. IMPORT ANT : Do not lift the unit by the condensate drain discharge pipe; hold it by its four co[...]

  • Page 8

    GB - 7 42 GW ENGLISH Installation  Threaded hangers  "T" bar (to be removed)    False ceiling  Spirit level             Suspension brackets  mm • T o ensure correct condensate water flow , the drain pipe should have a gradient of 2% without obstructions. Furthermore an odour tr[...]

  • Page 9

    42 GW GB - 8 A B Installation Installation of grille/frame assembly Carefully unpack the assembly and check for damage sustained in transit. Attach the assembly to the unit by using the two hooks. Use the screws supplied to fix the frame in position.  Frame pre-hooking support  Safety belt  Frame fixing screw A. Gasket "A" B. Gas[...]

  • Page 10

    GB - 9 42 GW ENGLISH • The unit control circuit only allows opening of the motorized valve when the fan motor is working. (See wiring diagrams) • When the thermostat asks for cooling, terminal 1 of TB3 (cold water) is supplied with 230V . When it asks for heating, terminal 2 of TB3 (hot water or electric heater) is supplied with 230V . • The [...]

  • Page 11

    42 GW GB - 10  Fan speed H = high speed M = medium speed L = low speed  Heat  Cool Motorized valve and control 230V valve connection or 230V valve relay connection Instructions for field supplied valves W ater connection • Install valves following manufacturer's instructions; refer to the relevant figures for connection to the unit.[...]

  • Page 12

    GB - 11 42 GW ENGLISH Motorized valve and control • If these connections are not made as described the drain pan condensate may overflow . • V alves should only open when the fan motor is working, i.e. when one of TB1 terminals 1 or 2 or 3 is supplied from TB1 terminal 4. • The optional electric heater (mod. 42GWE) which can only be factory i[...]

  • Page 13

    42 GW GB - 12 IMPORT ANT for units with electric heaters; The unit is equipped with two thermostats: one with automatic reset and one with manual (electric) reset that can be reactivated by switching the power supply off and then on. Connect the power cables to terminal box connectors in accordance with the wiring diagram and tighten firmly . IMPOR[...]

  • Page 14

    42 GW GB - 13 ENGLISH Electric heater supply Valves connection: select the diagram according to the system type 햻 햺 햹 햸 햲 햳 햴 햵 햶 햷 햿 헀 W W R A C C C C Y- G Y- G G G C C B B Y- G Y- G R R R R 12 3 4 5 67 9 1 23 67 81 0 11 5 4 3 2 1 TB3 TB1 HR F1 CR PR PCB IFM PS 1 2 FS 2 1 C2_F C2_M 2 1 3 2 C1_F 1 C1_M 1 2 3 6 5 4 3 2 1 C3_M[...]

  • Page 15

    42 GW GB - 14        Air intake grille Fresh air renewal and conditioned air supply to an adjacent room • Side knockouts allow connection of fresh air inlet ducts and ducts to deliver conditioned air to an adjacent room. • Remove the external prepunched anti-condensate insulation and take away the knockout panels using a[...]

  • Page 16

    GB - 15 42 GW ENGLISH Air flow m 3 /h Available static pressure - Pa Fresh air renewal • The optional supplementary fan for fresh air intake (field supplied) has to be connected to terminal block as per diagrams enclosed. Fan motor operation is parallel to the thermo-electric control valve, and the motor stops when the valve shuts off. • For wi[...]

  • Page 17

    42 GW GB - 16 Maintenance and owner's guide Maintenance Cleaning and maintenance operations must be carried out by specially trained personnel. Before performing any service or maintenance operations, turn OFF the main power switch. T o open the unit grille: T urn the two screws through 90 ° (1/4 turn). Filter cleaning Clean filters in accord[...]

  • Page 18

    L010122H22 - 0405 Via R. Sanzio, 9 - 20058 Villasanta (MI) Italy - T el. 039/3636.1 The manuf acturer reser ves the right to change any product specifications without notice . Order No. 14207-74M10, April 2005. Supersedes Order No. 14207-74M10, December 2004. Printed in Italy[...]