Carrier 48PG03---16 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Carrier 48PG03---16, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Carrier 48PG03---16 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Carrier 48PG03---16. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Carrier 48PG03---16 should contain:
- informations concerning technical data of Carrier 48PG03---16
- name of the manufacturer and a year of construction of the Carrier 48PG03---16 item
- rules of operation, control and maintenance of the Carrier 48PG03---16 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Carrier 48PG03---16 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Carrier 48PG03---16, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Carrier service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Carrier 48PG03---16.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Carrier 48PG03---16 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Manufa cturer res erves the right to discon tinue, or chang e at any time , specificat ions or designs witho ut notic e and wit hout inc urring obligati ons. PC 111 Cat alog No . 0 4-53 4800 06-0 1 Prin ted in U . S.A . F orm 48PG- 5SO Pg 1 8-05 R epla ces: 4 8PG- 4SO Book 1 4 Ta b 1 a 6 a User’ s Inf o r mation Manual NO TE T O INST ALLER: This [...]

  • Page 2

    2 T O LIGHT UNIT (Units with Electr o-Mechanical Contr ol) See Fi g. 1 f or locat ion of gas va lve. R efer t o Fig . 2 wh ile proceeding with the following steps. Step 1 — Set r oom the rmos tat to th e lowes t tempe ratur e setting and set SYSTEM switch to OFF position. Step 2 — Close the shutoff valve on the gas supply piping. Step 3 — T u[...]

  • Page 3

    3 LOCK-OUT TA G ON OFF MAIN O F F ON C HI M R E P L A C E S C R E W L O O F F ON C HI M R E P L A C E S C R E W L O STEP 1 Fig. 2 — To Light Unit (Units with Electro-Mechanical Control) STE P 5 STEP 4 STE P 3 STEP 2 STEP 8 STEP 7 STEP 6 STEP 10 STEP 9[...]

  • Page 4

    4 LOCK-OUT TA G ON OFF MAIN O F F ON C HI M R E P L A C E S C R E W L O O F F ON C HI M R E P L A C E S C R E W L O Run Status Service T est T emperature Pressures Setpoints Inputs Outputs Configuration Time Clock Operating Modes Alarms Alarm Status ENTER MODE ESCAPE STEP 1 Fig. 3 — To Light Unit (Units with Comfort Link™ Control) STE P 5 STEP [...]

  • Page 5

    5 Step 8 — Remove lockout tag and turn on the electrical supply to unit. Normal operation w ill automatically begi n. Servic e T est mode w ill aut omatica lly end (e xit) af ter a rec ycle of power . Step 9 — Open the shutoff valve on the gas supply piping. Step 10 — T o test the operation of the gas section, the HEA T submenu of Service T e[...]

  • Page 6

    6 STEP 1 Fig. 4 — To Shut Unit Off (Units with Electr o-Mechanical Control) STEP 7 STEP 6 STEP 5 STEP 4 STEP 3 STEP 2 LOCK-OUT TA G ON OFF MAIN STEP 3 O F F ON C HI M R E P L A C E S C R E W L O[...]

  • Page 7

    7 STEP 1 Fig. 5 — To Shut Unit Off (Units with Comfort Link™ Control) STEP 7 STEP 6 STEP 5 STEP 4 STEP 3 STEP 2 LOCK-OUT TA G ON OFF MAIN STEP 3 O F F ON C HI M R E P L A C E S C R E W L O Run Status Service T est T emperature Pressures Setpoints Inputs Outputs Configuration Time Clock Operating Modes Alarms Alarm Status ENTER MODE ESCAPE[...]

  • Page 8

    8 MA INT A ININ G Y OUR U NIT All maintenance shoul d be handled by skilled, experienc ed personnel. Y our dealer can help you establish a standard procedure. For your safety , keep the area around the unit cl ear and free of combustible materials, gasoline and other flammable liquids and vapors. T o assure proper functioning of the unit, flow of c[...]

  • Page 9

    9 and the Alarm Status LED is on, conta ct the local dealer and request service. Inte gra ted G as Co nt roller (IG C) — The IG C board incorporates an LED that em its a flashing light to indicate an alarm code. If the f urnace section wil l not operate and the LED is flashing a code (1 to 9 flashes in succession), contact your dealer and r eques[...]

  • Page 10

    10 REGULAR DEALER MAINTENANCE In addition to the type of routine maintenance you might be willing to perform, your unit should be inspected regularly by a properly trained service technician. An inspection (preferabl y each year , but at l east every other ye ar) should include the following: 1. Inspection of all flue product passages — inc ludin[...]

  • Page 11

    [...]

  • Page 12

    Manufa cturer reser ves the right to discon tinue, or change at any time, specificat ions or designs w ithout not ice and without incurrin g obligations. PC 111 Catalog N o. 04 -5348 0006-01 Printed in U.S.A. Form 48PG-5 SO Pg 12 8-05 Replace s: 48PG-4S O Book 1 4 Ta b 1 a 6 a Copyright 2 005 Car rier Cor poration[...]