A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Carrier Thermostat, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Carrier Thermostat one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Carrier Thermostat. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Carrier Thermostat should contain:
- informations concerning technical data of Carrier Thermostat
- name of the manufacturer and a year of construction of the Carrier Thermostat item
- rules of operation, control and maintenance of the Carrier Thermostat item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Carrier Thermostat alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Carrier Thermostat, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Carrier service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Carrier Thermostat.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Carrier Thermostat item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Programmable Thermostats Installation, Start-Up, and Operating Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since the last issue. INDEX Page SAFETY CONSIDERATIONS .....................................................1 INTRODUCTION .........................................[...]

  • Page 2

    • Close to or in a frequently used room, preferably on an inside partitioning wall. • On a section of wall without pipes or duct work. Thermostat should NOT be mounted: • Close to a window, on an outside wall, or next to a door leading to the outside. • Exposed to direct light and heat from a lamp, sun, fireplace, or other temperature-radia[...]

  • Page 3

    12. Turn ON power to unit. On power up, all display segments will light for 5 sec. For the next 5 sec, a 2-digit code appears on large display which identifies thermostat configuration: 1. AC—for 1-speed air conditioner 2. HP—for 1-speed heat pump 3. A2—for 2-speed air conditioner 4. H2—for 2-speed heat pump 5. HS—for intelligent heat sta[...]

  • Page 4

    4. Press SET TIME/TEMP button again to flash upper small display for selection of another option, or press END to exit configuration mode. Option 3—Fahrenheit or Celsius Operation Select between Fahrenheit and Celsius operation. Factory default is Fahrenheit. TO SELECT OR ADJUST: 1. Enter configuration mode if not already there. See above. Use up[...]

  • Page 5

    stay on and turn Cool Stage 1 on. For actual outputs, refer to Table 2, making sure the correct row from the table is selected. To turn off, raise cooling set point above the room temperature. Cool Stage 1 and the triangle will turn off within a few seconds. If system has 2 cooling stages, it will start on Cool Stage 1 and proceed to Cool Stage 2, [...]

  • Page 6

    → Table 2—Programmable Thermostat Quick Reference THERMOSTAT OUTPUT TSTAT Model Outdoor Unit AC/HP Configuration (Switch C) Staging Configuration (Switch D) 24v Hot Common Fan Heat Stage 1 Heat Stage 2 Heat Stage 3 Heat Stage 4 Cool Stage 1 Cool Stage 2 Reversing Valve AC01-B AC EITHER EITHER R C G W/W1 N/A N/A N/A Y/Y2 N/A N/A HP01-B HP OFF EI[...]

  • Page 7

    → Fig. 2—Single-Speed Air Conditioner with Single-Stage Furnace—Model AC Thermostat A98485 24 VAC HOT FAN HEAT STAGE 1 COOL STAGE 1 N/A N/A R G W/W1 Y/Y2 O/W2 Y1/W2 R G W Y 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y C MODEL AC THERMOSTAT SINGLE-STAGE FURNACE SINGLE-SPEED AIR CONDITIONER See note 1 SUGGESTED DIP SWITCH SETTINGS ON[...]

  • Page 8

    → Fig. 7—Single-Speed Heat Pump with Typical Fan Coil—Model HP Thermostat A98490 24 VAC HOT FA N RVS COOLING COOL /HEAT STAGE 1 HEAT STAGE 2 N/ A R G W/W1 Y/Y2 O/W2 Y1/W2 R G 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y C MODEL HP THERMOSTAT TYPICAL FAN COIL SINGLE-SPEED HEAT PUMP See notes 3, 7, and 8 Y W2 * W3 E R O W2 SUGGESTED [...]

  • Page 9

    → Fig. 11—Two-Speed Heat Pump with Single-Stage Furnace —Model 2S Thermostat A98494 COOL/HEAT STAGE 1 RVS COOLING HEAT STAGE 3 COOL/HEAT STAGE 2 FAN 24 VAC HOT R W/W1 Y/Y2 O/W2 Y1/W2 G 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y Y2 C W2 MODEL 2S THERMOSTAT SINGLE-STAGE FURNACE TWO-SPEED HEAT PUMP See notes 3, 9, and 11 R Y1 O R W3[...]

  • Page 10

    → Fig. 15—Single-Speed Air Conditioner with Variable-Speed Fan Coil (FK, FV, 40FKA)—Model AC Thermostat A98498 24 VAC HOT HEAT STAGE 1 N/A FAN N/A COOL STAGE 1 R R 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C G G C MODEL AC THERMOSTAT EASY SELECT TERMINAL BOARD J1 JUMPER J2 JUMPER SINGLE-SPEED AIR CONDITIONER See notes 1 and 8 DH Y1 [...]

  • Page 11

    → Fig. 19—Single-Speed Packaged Air Conditioner with Single-Stage Gas Furnace (48SS, SX) A98502 24 VAC HOT FAN HEAT STAGE 1 COOL STAGE 1 N/A N/A R G W/W1 Y/Y2 Y1/W2 O/W2 B S1 S2 MODEL AC THERMOSTAT RED GRN WHT YEL BRN See notes 1 and 11 C 24 VAC COMM N/A SPLICE BOX SUGGESTED DIP SWITCH SETTINGS ON ABC D OUTDOOR SENSOR CONNECTION → Fig. 17—T[...]

  • Page 12

    → Fig. 23—Single-Speed Packaged Heat Pump with 2-Stage Electric Heat (50HS, HX, ZH) A98506 R G Y/Y2 Y1/W2 B S1 S2 MODEL HP THERMOSTAT SPLICE BOX VIO ORN WHT RED (TRAN) BRN WHT BRN See notes 3, 10, 11, and 12 C O/W2 W/W1 24 VAC COMM N/A OUTDOOR SENSOR CONNECTION HEATER CONTROL BOX YEL GRN RED RED PNK HEAT STAGE 2 COOL/HEAT STAGE 1 RVS COOLING N/[...]

  • Page 13

    → WIRING DIAGRAM NOTES 1. The AC model thermostat can only control 1-stage cool and 1-stage heat. Dip Switch-C on has no controlling function and can either be ON or OFF. 2. HP and 2S model thermostat MUST have Dip Switch-C ON when installed in air conditioner applications. If required, second-stage heat is controlled by O/W2. Refer to indoor equ[...]

  • Page 14

    → OPERATIONAL INFORMATION Five-minute Compressor Timeguard This timer prevents the compressor from starting unless it has been off for at least 5 minutes. It can be defeated for 1 cycle by simultaneously pressing the FAN mode button and the INCREASE TEMPERATURE button. Fifteen-minute Cycle Timer This timer prevents the start of a heating or cooli[...]

  • Page 15

    A98508 PROGRAMMABLE THERMOSTAT CONFIGURATION RECORD Date Owner/Operator A) Hardware Configuration  Switch A Zoning Selection. (OFF = Disable, ON = Enable)  Switch B Smart Recovery. (OFF = Enable, ON = Disable)  Switch C Heat Pump Operation. (OFF = Enable, ON = Disable)  Switch D Intelligent Heat Staging. (OFF = D[...]

  • Page 16

    SERVICE TRAINING Packaged Service Training programs are an excellent way to increase your knowledge of the equipment discussed in this manual, including:  • Unit Familiarization • Maintenance  • Installation Overview • Operating Sequence A large selection of product, theory, and skills programs is available, us[...]