Go to page of
Similar user manuals
-
Fan
Casablanca Fan Company 59082
20 pages 9.58 mb -
Fan
Casablanca Fan Company 46U73M
14 pages 2.04 mb -
Fan
Casablanca Fan Company 59065
19 pages 8.5 mb -
Fan
Casablanca Fan Company 54037
22 pages 17.87 mb -
Fan
Casablanca Fan Company 55007
22 pages 17.87 mb -
Fan
Casablanca Fan Company 54019
16 pages 19.63 mb -
Fan
Casablanca Fan Company 59094
19 pages 8.79 mb -
Fan
Casablanca Fan Company 59109
20 pages 6.61 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Casablanca Fan Company 54001, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Casablanca Fan Company 54001 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Casablanca Fan Company 54001. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Casablanca Fan Company 54001 should contain:
- informations concerning technical data of Casablanca Fan Company 54001
- name of the manufacturer and a year of construction of the Casablanca Fan Company 54001 item
- rules of operation, control and maintenance of the Casablanca Fan Company 54001 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Casablanca Fan Company 54001 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Casablanca Fan Company 54001, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Casablanca Fan Company service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Casablanca Fan Company 54001.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Casablanca Fan Company 54001 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
www .CasablancaF anC o.com 1.888.227.2178 1 M6018-01 • 07/01/13 • © Casablanca F an Company T able of C ontents PA G E 7 PA G E 10 PA G E 5 PA G E 6 30 inches 7 feet PA G E 2 What to Expect with Y our Installation Ceiling Br acket Ladder PA G E 3 T ools Needed Wiring C anopy Downrod Prepar ation PA G E 11 PA G E 4 Mounting Options PA G E 12 Bl[...]
-
Page 2
www .CasablancaF anC o.com 1.888.227.2178 2 M6018-01 • 07/01/13 • © Casablanca F an Company What t o Expec t with Y our Installation Know your wiring If you are unfamiliar with wiring, use a qualied electrician. Y ou may need a friend to help you. Check box to see fan weight Assess location 30 inches from blade tip to nearest wall or obstru[...]
-
Page 3
www .CasablancaF anC o.com 1.888.227.2178 3 M6018-01 • 07/01/13 • © Casablanca F an Company T ools Needed Ladder Po wer Drill (optional) 9/64” Drill Bit (optional) Screwdrivers Pliers Wire Strippers If mounting to a support structure, you will also need these tools .[...]
-
Page 4
www .CasablancaF anC o.com 1.888.227.2178 4 M6018-01 • 07/01/13 • © Casablanca F an Company If you ha ve an angled ceiling: 1. Y ou will need a longer downrod (sold separately) . 2. If your ceiling angle is greater than 34°, y ou will also need an Angled Mounting Kit (sold separately) . Guide T ouches BOTH Ceiling & Wa ll S I T U A T I O [...]
-
Page 5
www .CasablancaF anC o.com 1.888.227.2178 5 M6018-01 • 07/01/13 • © Casablanca F an Company 1.888.227.2178 www .CasablancaF anC o.com C eiling Bracket OFF Make sure all four bumpers are still attached. F or angled ceilings, point opening toward peak. Refer to warning w .1 on pg. 2 T o av oid possible elec trical shock, before installing your f[...]
-
Page 6
www .CasablancaF anC o.com 1.888.227.2178 6 M6018-01 • 07/01/13 • © Casablanca F an Company C eiling Bracket (c ontinued) Prepar ation D I S C A R D K E E P ! Remove the shipping blocks from the motor . Sav e the screws . They will be needed for blade iron installation. Note: Some fans will hav e a shipping ring instead of shipping blocks. Ple[...]
-
Page 7
www .CasablancaF anC o.com 1.888.227.2178 7 M6018-01 • 07/01/13 • © Casablanca F an Company Slid e Slid e 1 2 3 4 5 6 7 8 9 10 Sold Separately Included Longer Downrod for angled ceilings or ceilings 10’ or higher Shorter Downrod for fans installed close to ceiling Standard Downrod for c eilings 8-10’ high Option 1 Option 2 Option 3 skip to[...]
-
Page 8
www .CasablancaF anC o.com 1.888.227.2178 8 M6018-01 • 07/01/13 • © Casablanca F an Company KEEP! 8” 3/8” C U T & S T R I P (not to scale) Remove the pr e-installed setscrew so that the downrod can be inserted. Hand tighten the downrod (at least 4-5 full turns) until it stops. The wires can be cut, but leave at least 8” extending fro[...]
-
Page 9
www .CasablancaF anC o.com 1.888.227.2178 9 Downrod (c ontinued) 1.888.227.2178 9 www .CasablancaF anC o.com DO NO T PICK THE F AN UP BY THE CANOPY OR WIRES. Place the downrod ball into the slot in the ceiling bracket. Put the wires and do wnrod through the canopy . Let the canopy sit loosely on t op of the fan. M6018-01 • 07/01/13 • © Casabla[...]
-
Page 10
www .CasablancaF anC o.com 1.888.227.2178 10 M6018-01 • 07/01/13 • © Casablanca F an Company W iring F R O M C E I L I N G B R A C K E T F R O M F A N F R O M C E I L I N G F R O M C E I L I N G green/yellow stripe (grounding) green/yellow stripe green/yellow stripe Note: T o connect the wires , hold the bare metal leads together and place a w[...]
-
Page 11
www .CasablancaF anC o.com 1.888.227.2178 11 M6018-01 • 07/01/13 • © Casablanca F an Company Canop y No te: Fan style may vary . Lift the canopy into place so that the screw holes are aligned . Position the canopy so that, when lifted into place , the canopy ts into the hanging bracket as sho wn. Screw Holes Insert the two canopy screws fou[...]
-
Page 12
www .CasablancaF anC o.com 1.888.227.2178 12 M6018-01 • 07/01/13 • © Casablanca F an Company Blades 12 Y our blades are shielded with Dust Armor® which is a nanotechnology coating that repels dust. For cleaning the fan, use soft brushes or cloths to prevent scratching . Cleaning agents ma y damage the nishes. Insert grommets found in the h[...]
-
Page 13
www .CasablancaF anC o.com 1.888.227.2178 13 M6018-01 • 07/01/13 • © Casablanca F an Company Swit ch Housing F eed the wire plug through the center hole of the upper switch housing , then wrap keyhole slots around the screws and twist counterclockwise. Screw two housing assembly screws from the hardware bag halfwa y into the motor housing . I [...]
-
Page 14
www .CasablancaF anC o.com 1.888.227.2178 14 M6018-01 • 07/01/13 • © Casablanca F an Company Swit ch Housing (continued) Make sure the lower switch housing is securely attached to the upper switch housing. F ailure to properly secur e all 3 assembly screws could result in the switch housing xture falling . Connect the plugs from the upper a[...]
-
Page 15
www .CasablancaF anC o.com 1.888.227.2178 15 M6018-01 • 07/01/13 • © Casablanca F an Company Swit ch Housing (continued) Maintenanc e & Cleaning The pull chain controls the fan: from high to off . T o swit ch the direc tion of air ow , mov e the reverse switch to the opposite position. In warm wea ther , use downward air ow pattern. [...]
-
Page 16
www .CasablancaF anC o.com 1.888.227.2178 16 M6018-01 • 07/01/13 • © Casablanca F an Company T roubleshooting Exc essive wobbling • Tighten all of the blade and blade iron screws until they are snug. • Use the provided balancing kit and instructions to balance the fan. Noisy Operation • Tighten the blade and blade iron screws until they [...]