A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of CFM FCU-20, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of CFM FCU-20 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of CFM FCU-20. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of CFM FCU-20 should contain:
- informations concerning technical data of CFM FCU-20
- name of the manufacturer and a year of construction of the CFM FCU-20 item
- rules of operation, control and maintenance of the CFM FCU-20 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of CFM FCU-20 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of CFM FCU-20, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the CFM service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of CFM FCU-20.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the CFM FCU-20 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    better AIRFLO W by DESIGN TM    • F orward cur v ed impeller • Heavy guage, steel construction • Discharge rotatable to 8 positions • CW & CCW rotation • AMCA T ype A, B & C construction available • Arrangement 10, SWSI, Class I • Sizes range fr om 8” to 24”[...]

  • Page 2

    FCU UTILITY FANS 2 V-DIA.- 6 HOLES FOUNDATION LAYOUT V-DIA.- 4 HOLES BASE DETAIL SIZES 8, 9, & 11 K L J C H A F M N T D Q E B R X S P Q E F/2 F/2 BD Y E 5/8 Note: • Letter s “ C” and “D” are outside housing dimensions. • “ C” dimension extends beyond center -line, size #8 (5/ 16), size #9 ( 1 -9/ 16) & size # 11 ( 1 - 1 / 16[...]

  • Page 3

    3 Tip Speed (FPM) = 1.996 x RPM Outlet: .296 sq. ft. inside , 8.25” x 5.38” outside Inlet: .338 sq. ft. inside, 8” dia. outside Wheel Diameter : 7.75” Max. RPM: 3006 P erformance shown is f or installation T ype B - free inlet, ducted outlet. P ower rating (BHP) does not include drive losses . P erformance ratings do not include the effects[...]

  • Page 4

    4 Tip Speed (FPM) = 2.356 x RPM Outlet: .468 sq. ft. inside, 10.75” x 6.5” outside Inlet: .406 sq. ft. inside, 9” dia. outside Wheel Diameter : 9” Max. RPM: 2547 P erformance shown is f or installation T ype B - free inlet, ducted outlet. P ower rating (BHP) does not include drive losses . P erformance ratings do not include the effects of [...]

  • Page 5

    Tip Speed (FPM) = 2.782 x RPM Outlet: .636 sq. ft. inside, 11.75” x 8” outside Inlet: .525 sq. ft. inside, 10” dia. outside Wheel Diameter : 10.5” Max. RPM: 2157 FCU UTILITY FANS 5 509 572 636 700 763 827 890 954 1018 1081 1 145 1208 1272 1399 1526 1654 1781 1908 2035 2162 2290 2417 2544 2671 2798 2926 3053 3180 3307 3434 3566 3689 3816 C F[...]

  • Page 6

    FCU UTILITY FANS 6 Tip Speed (FPM) = 3.27 x RPM Outlet: .858 sq. ft. inside, 13.25” x 9.63” outside Inlet: .921 sq. ft. inside, 13.25 dia. outside Wheel Diameter : 12.25” Max. RPM: 1871 686 772 858 944 1030 111 5 1201 1287 1373 1459 1544 1630 1716 1888 2059 2231 2402 2574 2746 2917 3089 3260 3432 3603 3775 3947 41 18 4290 4462 4633 4805 4976 [...]

  • Page 7

    Tip Speed (FPM) = 3.534 x RPM Outlet: 1.049 sq. ft. inside,14.63” x 10.75” outside Inlet: 1.108 sq. ft. inside,14.50 dia. outside Wheel Diameter : 13.5” Max. RPM: 1698 7 FCU UTILITY FANS 839 944 1049 1 154 1259 1364 1469 1574 1678 1783 1888 1993 2098 2308 2518 2727 2937 3147 3357 3567 3776 3986 4196 4406 4616 4825 5035 5245 5455 5665 5874 608[...]

  • Page 8

    8 FCU UTILITY FANS Tip Speed (FPM) = 3.927 x RPM Outlet: 1.280 sq. ft. inside, 16.25” x 11.75” outside Inlet: 1.374 sq. ft. inside, 16.13 dia. outside Wheel Diameter : 15” Max. RPM: 1400 1024 1 152 1280 1408 1536 1664 1792 1920 2048 2176 2304 2432 2560 2816 3072 3328 3584 3840 4096 4352 4608 4864 5120 5376 5632 5888 6144 6400 6656 6912 C F M [...]

  • Page 9

    Tip Speed (FPM) = 4.189 x RPM Outlet: 1.560 sq. ft. inside,17.75” x 13” outside Inlet: 1.67 sq. ft. inside,17.88” dia. outside Wheel Diameter : 16.25” Max. RPM: 1313 9 FCU UTILITY FANS 1248 1404 1560 1716 1872 2028 2184 2340 2496 2652 2808 2964 3120 3432 3744 4056 4368 4680 4992 5304 5616 5928 6240 6552 6864 7176 7488 7800 81 12 8424 C F M [...]

  • Page 10

    10 FCU UTILITY FANS Tip Speed (FPM) = 4.712 x RPM Outlet: 1.899 sq. ft. inside, 19.63” x 14.25” outside Inlet: 2.02 sq. ft. inside, 19.63” dia. outside Wheel Diameter : 18.25” Max. RPM: 1061 1519 1709 1899 2089 2279 2469 2659 2849 3038 3228 3418 3608 3798 4178 4558 4937 5317 5697 6077 6457 6836 7216 7596 7976 8356 8735 91 15 9495 C F M Outl[...]

  • Page 11

    Tip Speed (FPM) = 5.236 x RPM Outlet: 2.316 sq. ft. inside, 21.5” x 15.88” outside Inlet: 2.435 sq. ft. inside, 21.5” dia. outside Wheel Diameter: 20” Max. RPM: 955 11 FCU UTILITY FANS 1853 2084 2316 2548 2780 301 1 3242 3474 3706 3937 4169 4400 4632 5095 5558 6022 6485 6948 741 1 7875 8338 8801 9264 9727 10190 10654 1111 7 1 1580 12043 C F[...]

  • Page 12

    12 FCU UTILITY FANS Tip Speed (FPM) = 5.236 x RPM Outlet: 2.827 sq. ft. inside, 24” x 17.38” outside Inlet: 3.015 sq. ft. inside, 23.88” dia. outside Wheel Diameter : 22.5” Max. RPM: 858 2262 2544 2827 31 10 3392 3675 3958 4241 4523 4806 5089 5371 5654 6219 6785 7350 7916 8481 9046 9612 10177 10743 1 1308 1 1873 12439 13004 13570 14135 1470[...]

  • Page 13

    Tip Speed (FPM) = 6.414 x RPM Outlet: 3.458 sq. ft. inside, 26.25” x 19.25” outside Inlet: 3.650 sq. ft. inside, 26.38” dia. outside Wheel Diameter : 24.5” Max. RPM: 779 13 FCU UTILITY FANS 2766 31 12 3458 3804 4150 4495 4841 5187 5533 5879 6224 6570 6916 7608 8299 8991 9682 10374 1 1066 1 1757 12449 13140 13832 14524 15215 15907 16598 1729[...]

  • Page 14

    FCU UTILITY FANS 14 DB CLOCK WISE TH CLOCK WISE UB CLOCK WISE BH CLOCK WISE UB COUNTER-CLOCK WISE BH COUNTER-CLOCK WISE DB COUNTER-CLOCK WISE TH COUNTER-CLOCK WISE BAU CLOCK WISE TA D CLOCK WISE BAD CLOCK WISE TA U CLOCK WISE TA D COUNTER-CLOCK WISE BAD COUNTER-CLOCK WISE TA U COUNTER-CLOCK WISE BAU COUNTER-CLOCK WISE DESIGNA TIONS FOR RO T A TION [...]

  • Page 15

    FCU UTILITY FANS 15 PRODUCT SPECIFICA TION GUIDE 1.0 GENERAL A. F ans shall be model FCU, as man ufactured b y Continental F an Manuf acturing Inc., of Buffalo , NY , and of the size, capacity and rotation as indicated on the dra wings and fan schedule . B. F ans shall be single width, single inlet, arrangement 10, class I. C . F ans shall be rated[...]

  • Page 16

    FCU-W- 1004 FCU UTILITY FANS[...]