Go to page of
Similar user manuals
-
Safety Gate
Chamberlain GA400D
48 pages 10.19 mb -
Safety Gate
Chamberlain RESIDENTIAL GATE OPERATOR GA400D
48 pages 1.87 mb -
Safety Gate
Chamberlain LIFTMASTER PROFESSIONAL SW470
40 pages 1.23 mb -
Safety Gate
Chamberlain SW490
40 pages 3.18 mb -
Safety Gate
Chamberlain SL920
32 pages 2.94 mb -
Safety Gate
Chamberlain ESTATE SERIES SW 2000-X3
48 pages 1.59 mb -
Safety Gate
Chamberlain Swing GATE
54 pages 2.68 mb -
Safety Gate
Chamberlain SL 1000-XI
39 pages 1.73 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Chamberlain LA412, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Chamberlain LA412 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Chamberlain LA412. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Chamberlain LA412 should contain:
- informations concerning technical data of Chamberlain LA412
- name of the manufacturer and a year of construction of the Chamberlain LA412 item
- rules of operation, control and maintenance of the Chamberlain LA412 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Chamberlain LA412 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Chamberlain LA412, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Chamberlain service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Chamberlain LA412.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Chamberlain LA412 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
The Cha mber lain Gro up, Inc. 84 5 Lar ch Avenue Elmhurst, Illinois 60 1 26- 1 1 9 6 www . l i ft ma st er . co m 12 VOLT DC SINGLE SOLAR RESIDENTIAL GATE OPERATOR Models LA412 and LA412-S For Residential Use Only Owner’s Manual ■ Please read this manual and the enclosed safety materials carefully! ■ Periodic checks of the operator by a qual[...]
-
Page 2
TABLE OF CONTENTS 2-7 INTRODUCTION 2 Safety Symb ol and Sign al Word Re view 3 Oper a to r Sp ecifi catio ns 4-5 Safe t y Installation Information 6 Carto n Inventory 6 Hardw are In v ent ory 7 Addit ional Items for Purchase 7 T ools Needed 8-12 PREPARATION AND OVERVIEW 8 Single Gate Overview 9 Dual Ga te Ov er view 10 Check Y our Gate 11 Moun tin[...]
-
Page 3
Operator Dimensions and Specifications Mai n S upp ly 1 2VDC Bat ter y run. O perati onal bet ween 1 1 .5VDC an d 1 4.5VDC. Access or y Power 1 2V nominal Class II batter y voltage sourc e is limited to: • Solar or AC Cable up to 50' - 50 0 mA • AC Cable 50' up to 250' - 250 mA • AC Cable 250' up to 1 00 0' - 100mA NO[...]
-
Page 4
1 . READ and FOLLO W all instruc tions. 2. The gate operator is intende d for use with Class I vehicular swing gates. Class I denotes a vehicular g ate operator (or system) intended for use in a ho me of one to four single fa m i l y dwelling s, or a garage or parking area as soc iated therewith . Install the g ate operator only when the oper ator [...]
-
Page 5
1 3. Eac h gate operator is provided wit h two safet y warning placar ds. The p lacard s are to be installe d on the fro nt and back of the g ate where they are plainly visible. The placar ds may be mounted using ca ble ties through t he four holes provide d on each p lacard. All warning signs and plac ards mu st be installed where visi ble in the [...]
-
Page 6
Car ton Inventory This oper ator comes with th e hardware to install on a g ate that pulls-to- ope n . If your app licati on requires the g ate to be pushed open , acc essor y kit 50 - 1 9503 i s required. W arning Signs (2) Moving Gate Can Cause Injury or Death KEEP CLEAR! Gate may move at any time without prior warning. Do not let children operat[...]
-
Page 7
Additional Items For Purchase The following items are REQUIRED to comp lete the installation: SAFETY SENSORS The Mo del 50 -2 20 safety sensor s are intended for installation with the o perators covered in this manual. T o order c all 1 -8 00 - 528-280 6 or visit w w w .lif tm aster .com. HARDWARE • 5 /1 6" mount ing hardware for gate bracke[...]
-
Page 8
Mo v i ng Gate Ca n Ca use Injur y or Death KEEP CL EAR! Gate ma y m ov e a t a ny time wi thou t p rior wa rn in g. Do n o t l e t c h ildren o pera te t he g ate o r play i n t h e g ate area. Th is e nt r a nc e i s f or vehi cles on ly Pe de str ia ns m u st use sep ar ate e nt r an ce 12 gauge wire 8 ft. (2.4 m) To prevent SERIOUS INJURY or DE[...]
-
Page 9
Outside Property Inside Property Mo vi ng Gat e Ca n C au se In jur y o r D eath KE EP CLE AR ! Gate m ay move at a ny tim e w it ho ut pr ior w arnin g. Do no t let childr en op er ate th e g ate or pla y in t he g ate area. T his e nt r ance is f or ve hicl e s o nly Pedes tri ans mu s t use se pa r ate ent ra nc e Direction of Gate 1 ravel T Dir[...]
-
Page 10
Check Y our Gate Gate MUS T be lev el. Gate and gate post MUST be plumb . Remove ANY /ALL wheels fro m the bot tom of gate. Gate MUST NO T hit or dr ag across ground. Gate MUST s wing freely and be sup por ted entirely by its hinges. Preparation and O ver view 1 0[...]
-
Page 11
Mounting Options Mounting lo catio ns vary d epend ing on the t yp e and st yle of your gate. NOTES: • The top of the operator must be mounted at least 10 inches above the ground. Environmental conditions should be considered at this time. • The operator is not recommended for plastic or vinyl gates. Contact the gate’s manufacturer for recomm[...]
-
Page 12
1 MANUAL RELEASE Inser t the key into the loc k and turn it 180° counterclo ck wise. T urn the release leve r 1 80° c ounterclo ck wise. The op erator is now in manual mod e. 2 DETERMINE THE POSITION OF THE EXTENSION BRACKET The extensio n bracket can be assem bled to work o n a Left-Hand or a Right-Hand gate. Re view the gate t ypes below and se[...]
-
Page 13
3 MEASURING AND MARKING FOR THE GATE BRACKET Before procee ding, begi n with the gate in the fully close d positio n. There are t wo method s for determining the proper lo catio n of the po st brackets : • Paper template (located on the bac k page of this manual. Mu st be cut out.) • T ape measure. Either metho d will work dep ending on prefere[...]
-
Page 14
4 POSITION THE EXTENSION BRACKET TO POST BRACKET Assemble t he post brac ket b y placing t he extension br acket on top of post brac ket. Inser t the bolt t hrough the brackets and fasten them using t he washer , lo ck washer and nut . DO N OT T I GH T E N AT T HIS T IME . Lock W asher Nut Hex Bolt 3/8" Extension Bracket Post Bracket W asher H[...]
-
Page 15
6 7 POSITION GATE OPERATOR ON GATE The post brac ket assembly can b e mounted several places on the gate post. Refer to page 1 1 for mounting optio ns. Place the oper ator arm against gate post at the desired ver ti cal po sition and tem porarily se cure post br acket with a clamp . The g at e ope r at or (arm) mus t b e lev el. Open t he gate to d[...]
-
Page 16
8 TEST GATE TRAVEL Manually op en and close t he gate. Ensure that the operator does n ot bind against the pull -to - open brac ket. Ensure that the piston d oes not bot tom out. 1/2" (1.3 cm) Do not allow piston to fully extend or fully retract. 1/2" (1.3 cm) NOTE: If gate does not open and close completely adjust the position of the gat[...]
-
Page 17
9 SECURE POST BRACKET TO GATE POST Mark holes for the p ost bracket. Remove the clamp and t he oper ator , an d set both aside. Next, dr ill adequ ate holes in the gate post. Welder (Optional) Secure the p ost brac ket to the gate post using hardware. The gate operator (arm) mu st be level . Flat Washers Hex Nuts Lock Washers Carriage Bolts 10 SECU[...]
-
Page 18
To prevent SERIOUS INJURY or DEATH from a moving gate: • Install warning signs on the front and back of the gate in PLAIN VIEW. • Permanently secure each warning sign in a suitable manner using fastening holes. 11 WARNING SIGN PLACEMENT Wa rning plac ard s MUST be installed on both sides of th e gate and in plain view . Fasten them to the gate [...]
-
Page 19
13 MOUNT THE CONTROL BOX The control box MUST be mounted within 5' of the gate operator. Mount the control box as high as possible for best radio reception. RESE T Screws (4) Open the Control Box Remove screws and open the control box. Remove the Control Board Disconnect the reset button, alarm, and coaxial connector. Loosen screws to remove t[...]
-
Page 20
MOUNT THE CONTROL BOX (CONTINUED) Secure the c ontrol b ox to mounting sur face (p ost, wall, column, etc.) us ing the appro priate hardware (not provid ed ). 14 INSTALL THE CONTROL BOARD Attach t he antenna. Reinstall the bat teries, contro l board, alar m, and reset but ton. NOTE: Make sure the battery leads are on the left side of the control bo[...]
-
Page 21
FUSE OPEN Mo vin g G a te C an C aus e I njur y or Death KEEP CL EAR! Gate may move a t any tim e w ith o u t pri o r wa rn in g. Do n o t le t chi ld ren op era te th e ga te or p la y in th e gate area. This en tra nce is for veh ic le s on ly Pedest ria ns mus t use sep ar a te en trance FUSE OPEN C4 Control Box 18 18 R93 R93 D42 K2 K2 Z22 Z22 P[...]
-
Page 22
3 CONNECT THE OPERATOR TO THE CONTROL BOARD Ex tend th e operator ca ble and wires to th e Gate 1 conne ctor and c onnec t as shown. Tighten watertight c onnec tor nut. Mo vin g G a te C an C aus e I njur y or Death KEEP CL EAR! Ga te may move a t any tim e w ith o u t pri or warn in g. Do n o t le t chi ld ren op era te th e ga te or p la y in th [...]
-
Page 23
Connect the Gate Operator (Gate 2) to the Control Box (Model L A412-S Only) Occ asionally in d ual gate installations, one g ate will need to open fi rst and close se con d. This would hap pen if there was an ornamental overhang on one g ate or if using a solenoid lo ck , for example. This gate is called the Primar y g ate and needs to b e conne c[...]
-
Page 24
5 CONNECT SECOND OPERATOR TO CONTROL BOARD (MODEL LA412-S ONLY) • Before digging, c ontac t loc al underground ut ility locating companies. • T rench acros s drivew ay to bury the ex tension cabl e. • Use PV C c onduit to prevent damage to c ables. • Select h ole in bot tom of the c ontrol box to be use d for the extension c able. • Inser[...]
-
Page 25
6 JUNCTION BOX The following items are required to c omplete the junc tion b ox installation : • 4 x 4 Juncti on Box with 3 /4" NPT threaded por t h oles • Screws • PV C C onduit Open th e juncti on box by removing screws (4) and set aside. Mount the jun ctio n box within 5' of second op erator . Junction Box Cover Junction Box Movi[...]
-
Page 26
7 CONNECT WATERTIGHT CONNECTORS Route operator cable an d extension cable t hrough watertight c onnec tor nut and watertight c onnec tor . Inser t ca bles and watertight c onnec tors into th e holes in the bot tom of the jun cti on box (not provided) . Feed extension ca ble through PV C c onduit and se cure with co nnector nut. Junction Box (not pr[...]
-
Page 27
SOLAR PANEL INSTALLATION Select Site for Solar Panel(s) The solar panel(s) must be located in an open area clear of obstructions and shading for the entire day. The solar panel(s) comes with a 10' cable. If a location near the control box cannot be found, an additional cable will be required. The LA412 Solar Gate Operator is not supported in n[...]
-
Page 28
1 OVERVIEW OF SOLAR PANEL INSTALLATION Make sure the control b ox has two 1 2V 7 AH batteries inst alled. Do not co nnect batteries until instruc ted. Solar Panel (facing South) Control Box Solar Panel Installation 28[...]
-
Page 29
2 POSITION SOLAR PANEL(S) NOTE: If the panel(s) is not casting a shadow, the battery is not being charged. The loc ation of the panel (s ) is crit ical to th e succ ess of the inst allation. In general, the panel (s) s hould be mounted using the provid ed angle brac ket facing due south . The solar panel ( s) should b e mounted in an area clear of [...]
-
Page 30
3 POSITION SOLAR BRACKET Position solar bracket on mounting sur fac e. Mark and drill holes. NOTE: Solar panel(s) MUST be installed facing south. Use a compass to determine direction. 4 INSERT MOUNTING BOLTS Inser t t wo bolts into th e track lo cated on the bac k of the solar panel ( s) . Slide bolts in track away from bolt hole and align both bol[...]
-
Page 31
7 CONNECT SOLAR PANEL(S) TO OPERATOR CONTROL BOX Open th e control b ox cov er . Disc onne ct all power and batteries from th e control b oard. Run the so lar panel cabl e to the bot tom of th e contro l box. Thread the cable t hrough the watertig ht conne ctor and pull the cable t hrough until it reaches th e AC PWR/SOLAR conne ctor on th e contro[...]
-
Page 32
8 CONNECT BATTERIES The batteries are c harge d in circ uit by using the solar panel (provided ). Locate the t wo white batter y p lugs on th e lef t-hand side of the c ontrol b ox. Connect the p lug from the batter y to c onnec tor on the c ontrol b oard. NOTES: Batteries will degrade over time depending on temperature and usage. For best performa[...]
-
Page 33
PROGRAMMING Program Limits The limits are internal set ting s that indic ate when the gates ar e in the fully op en position an d the fully close d positio n. For proper func tionalit y , the limit s must be programm ed during the inst allation proces s. The program ming uses a com bination of butto ns on the c ontrol b oard. The spe cifi c button[...]
-
Page 34
NOTES: • The gate with the longer travel span (opening) must be set as the primary gate (GATE 1). • If one gate is overlapping the other, the gate that is overlapping must be connected to GATE 1 so it will start moving before the other gate; gate 2 may need to be closed fi rst if there is overlap or a gate lock is being used. • The programmi[...]
-
Page 35
Force and Timer to Close FORCE ADJUSTMENT The operator is equi pped a with an o bstruc tion sensing feature . If the gate encounters an o bstru cti on the o perator will automatic ally rev erse dire ctio n and stop. Based on t he length and weight of t he gate it may be necessar y to make force adjust ments. Th e force adjust ment shoul d be high e[...]
-
Page 36
Z22 R91 CLOSE EDGE R94 R92 R93 L1 R1 R2 Z1 K5 K6 K2 F3 10A 32V D1 Ø OPEN EDGE/ PHO T O OPEN PHO T O CLOSE PHO T O R227 R2 Ø 7 Z2 Ø R223 P1 Z9 Z8 F2 F6 D4 R9 R224 U4 CONTROL INPUTS FORCE TIMER TO CLOSE OFF MAX OPEN SINGLE BUTTON RESET STOP SHADOW INTERRUPT CHGR OVLD COM COM COM LOOP INPUTS POWER F1 20A 32V R35 D9 Z3 Z4 U3 C11 C13 C12 D15 C2 R4 R1[...]
-
Page 37
OPERATION AND MAINTENANCE 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. NEVER let children operate or play with gate controls. Keep the remote control away from children. 3. ALWAYS keep people and objects away from the gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the gate operator monthly. The gate MUST reverse on contact with a rigid o[...]
-
Page 38
MANUAL RELEASE In case of a power failure, the operator ca n be diseng aged from the gate. With an operator , the release ac tion may sometimes feel stif f / jer k y , whic h is normal and has n o effect on function . RELEASE 1 . Inser t the key into the loc k. 2. T ur n the key counter - clo ck wis e 1 80° . 3. T urn t he release lev er counter -[...]
-
Page 39
EDGE EDGE 50-220 SAFETY SENSORS 50-220 SAFETY SENSORS OR OPEN (EXIT LOOP ) SINGLE BUTTON (SBC) RESET STOP SHADOW LOOP INTERRUPT LOOP 50-220 SAFETY SENSORS CLOSE EDGE R93 D42 K2 D1 Ø OPEN EDGE/ PHOTO OPEN PHOTO CLOSE PHOTO Z22 P1 F2 MOV1 D1 Q12 U4 CONTROL INPUTS FORCE TIMER TO CLOSE OFF MAX OPEN SINGLE BUTTON RESET STOP SHADOW INTERRUPT CHGR OVLD C[...]
-
Page 40
Y our gate operator is programm ed with self-d iagnostic c apabilit ies. The diagnost ic LED will fl ash a number of time s then pause signif ying it has found a potential issue. Consult Diagno stic Char t be low . Diagnostic Char t Operator is in sleep mode. Normal Operation Stop is not connected. • Check to make sure the jumper wire is connect[...]
-
Page 41
SYMPTOM POSSIBLE SOLUTION Operator does not run. • Power not connected. Make sure the AC/Solar input is connected and that at least Diagnostic LED not on. one battery is connected with the corresponding fuse intact. • Low or defective battery. Check the battery to make sure that the red wire goes to the positive terminal of the battery and the [...]
-
Page 42
SYMPTOM POSSIBLE SOLUTION The arm moves but cannot • Arm does not extend or contract enough during travel. The arm piston must extend exit Learn Limits mode. and contract close to its full length to Learn Limits. Adjust the arm mounting so that Cannot learn limits. this can be achieved. • Motor cable wire not connected. Make sure that all the m[...]
-
Page 43
43 Operati on and Maintenan ce SYMPTOM POSSIBLE SOLUTION Gate opens but does not • An open input is continuously activated. Check the open loop or vehicle probe to close. make sure they are clear of objects. Verify connections and operation for these devices. • Low battery. Measure the voltage across the battery. Voltage should be above 11.5Vdc[...]
-
Page 44
3 5 4 2 1 6 7 REPAIR PARTS Control Box ITEM PART # DESCRIPTION QTY 1 K 1 A6426 - 1 Control B oard with Mounting Bracket 1 2 K 23 - 1 938 0 Reset Switch 1 3 K7 4 - 34 392 Antenna 1 4 29 -N P7 1 2 Batter y 1 5 K76- 1 944 6 Alarm 1 6 SOLPNL 10 W 1 2V Solar Panel Not Shown LA 4 1 2 -CON T Complete 1 Control B ox K 1 A66 36 Receiver 1 Module 3 1 5MHz K [...]
-
Page 45
ACCESSORIES 3-Button SECURITY ✚ ® Remote Control: Incl udes vis or cl ip . Protector System ® Safety Sensors: The Safety Sensor s are recom mended for installation with the oper ators covered in this manual. Automatic Gate Lock: Solenoid - driven lo ck that automatic ally unlocks w hen gate is open and lo cks when gate is closed. Can b e mounte[...]
-
Page 46
WARRANTY POLICY LIFTMASTER ONE YEAR LIMITED WARRANTY Th e Chamb er lain Gr oup, Inc. wa rr an t s to th e fir s t re t ail pur ch as er of t his pr oduc t , for th e st ruc t ure in w hic h this pr odu ct i s or igin ally in stall ed , th at it i s fr ee fro m def ect i n ma te rial s an d/ or wo rkma ns hip fo r a p eri od of O NE yea r fr o m t h[...]
-
Page 47
[...]
-
Page 48
© 2008, The Chamberlain Group, Inc. 01-34491B All Rights Reserved TEMPLATE FOR POST BRACKET MOUNTING 7 6 5 4 3 2 1 7 6 5 4 3 2 1[...]