Go to page of
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Channel Plus 8051, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Channel Plus 8051 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Channel Plus 8051. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Channel Plus 8051 should contain:
- informations concerning technical data of Channel Plus 8051
- name of the manufacturer and a year of construction of the Channel Plus 8051 item
- rules of operation, control and maintenance of the Channel Plus 8051 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Channel Plus 8051 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Channel Plus 8051, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Channel Plus service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Channel Plus 8051.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Channel Plus 8051 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
3001 Enterprise Street, Brea, CA 92821-6213, U.S.A. 714-996-4100 * 800-999-5225 * F AX_714-996-4900 www .channelplus.com multiplex technology , inc. 8050 Series T elephone/Data Hubs Instruction Manual & Structured Wiring Guide 8050 Series T elephone/Data Hubs Instruction Manual & Structured Wiring Guide R R Integrated Home Networks Model 80[...]
-
Page 2
Expansion connector Jacks accept 6 position RJ-25 Or 8 position RJ-45 plugs POTS (Plain Old T elephone Service) Data/T elephone Hub applications Tie wrap mounting holes T o phone jacks 1 10 punch-down blocks Do not punch-down more than one wire per connector . From T elco Central Office lines (CO) CO1, CO2, CO3, CO4 From T elco Central Office lines[...]
-
Page 3
T elephone T ermination Option 1 - old style Black Black Green Green Y ellow Y ellow Red Red White/Orange White/Blue Orange Blue White/Brown Brown White/Green Green Pair s1&2 Pair s3&4 Dual Jack T elephone W allplate Pair s3&4 Pair s1&2 RJ-14 V oice Grade Jacks Cable Color Pin # Connector Color Pin 1 White/Orange Pin 2 White/Orange [...]
-
Page 4
How to wire a new house The Internet, multiple phone lines, cable television, satellite systems, and high speed data links are bringing more and more information to your home. The communication wiring in most houses is overwhelmed by these requirements. It doesn’t have to be that way . During construction, providing modern cabling is surprisingly[...]
-
Page 5
Phones today , data or KSU tomorrow Standard Cat-5 jumper cables (8091 - 1 foot, 8092 -2 foot) The most versatile phone/data systems use structured wiring concepts. The phone/data jacks located throughout the house are each connected to a unique jack on a model 8052 hub. Jumper cables are then used to connect phone, data, or a KSU port to that jack[...]
-
Page 6
T ypical 3x8 KSU (Panasonic KX-T30819) Standard RJ-14 jumper cables (2 pair) Connecting to a KSU White/Orange Orange White/Blue Blue White/Green Green RJ-45 RJ-1 1 RJ-1 1 RJ-1 1 CO 1 CO 2 CO 3 Create this custom cable by cutting off one end of a standard Cat-5 jumper . CA T-5 cables T o wallplates located throughout the house From T elco CO-1 CO3 S[...]
-
Page 7
Structured wiring basics: Alternative W ays to Mount the 8050 series hubs. Mount on Model 2600 enclosure... or mount on Model 2601 enclosure. or hang on sheet metal (such as Model 2602A cabinet)... T o protect the wiring, the 8050 series hubs should be in a network enclosure. ChannelPlus enclosures allow you to integrate telephone, data, and coax d[...]
-
Page 8
Integrated Home Networks CA T 5 Do's and Don'ts CA T 5 Do's and Don'ts Do not allow cable to kink or knot. Also, do not pull the cable with excessive force. Do not allow cable to kink or knot. Also, do not pull the cable with excessive force. When using tie-wraps to secure cable, do not cinch cables to where crush-stress is visi[...]
-
Page 9
3001 Enterprise Street, Brea, CA 92821-6213, U.S.A. 714-996-4100 * 800-999-5225 * F AX_714-996-4900 www .channelplus.com multiplex technology , inc. R 600-099 Rev A[...]