Chromalox VERSATHERM PE414-3 manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Chromalox VERSATHERM PE414-3, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Chromalox VERSATHERM PE414-3 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Chromalox VERSATHERM PE414-3. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Chromalox VERSATHERM PE414-3 should contain:
- informations concerning technical data of Chromalox VERSATHERM PE414-3
- name of the manufacturer and a year of construction of the Chromalox VERSATHERM PE414-3 item
- rules of operation, control and maintenance of the Chromalox VERSATHERM PE414-3 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Chromalox VERSATHERM PE414-3 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Chromalox VERSATHERM PE414-3, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Chromalox service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Chromalox VERSATHERM PE414-3.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Chromalox VERSATHERM PE414-3 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Chromalox ® (Supersedes PE414-2) PE414-3 NWH 161-304777-001 MA Y , 2007 4 RENEW AL P AR TS IDENTIFICA TION Installation, Operation and Cir culation Heaters for Oil or W ater Heating © 2010 Chromalox, Inc. Specifications – T able A GENERAL READ ALL INSTRUCTIONS BEFORE USE FIRE/EXPLOSION HAZARD. Ordinar y location heaters (designated E1) are not [...]

  • Page 2

    INST ALLA TION ELECTRIC SHOCK HAZARD. Disconnect all power before installing heater . Failure to do so could result in personal injur y or property damage. Heater must be installed by a qualified person in accordance with the National Electrical Code. NFP A 70. 1. V ertical Mounting (Preferred) — When the heater is vertically mounted, the electri[...]

  • Page 3

    3 WIRING ELECTRIC SHOCK HAZARD. Any installation involv- ing electric heaters must be performed by a quali- fied person and must be effectively grounded in accordance with the National Electrical Code to eliminate shock hazard. Ensure the correct W iring Guide is used for your heated medium and model type, and ensure the correct wiring diagram is u[...]

  • Page 4

    Oil Applications Appro x . Watts Wiring Watts-Volts Circuit-Phase (amps) /Sq. In. Diag. # PCN 100140 (P/N 052-304749-005) PCN 100298 (P/N 052-304749-305) .5kW - 240V 1-3Ph (1.3 amps) 2 #6 .75kW - 120V 1-1Ph (7 amps) 5 #13* .75kW - 208V 1-3Ph (2.1 amps) 5 #12* 1.5kW - 120V 1-1Ph (13 amps) 5 #7 1.5kW - 120V 2-1Ph (2 x 7 amps) 5 #8 1.5kW - 208V 1-3Ph [...]

  • Page 5

    5 WIRING GUIDE – W A TER (NWHSRG) Directions: Step 1: Select the PCN number below which matches the PCN number on your heater . Step 2: Choose your kW , Volts, phase, and number of cir cuits under your PCN number (you must know the kW and watt density (watts/sq. in.) needs for your application) . Step 3: Note the Wiring diagram # for your selecti[...]

  • Page 6

    6 WIRING 120V 208V 240V 480V .5kW 1.5kW 2.5kW 4.5kW 6.0kW 10.0kW STEP 5: PEEL OFF THE APPROPRIA TE VOL TS, CIRCUIT -PHASE, AND kW , AND AFFIX TO NAMEPLA TE. STEP 4: PEEL OFF APPROPRIA TE WIRING DIAGRAM AND AFFIX TO INSIDE OF ELECTRICAL ENCLOSURE. #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #1 1 #12 #13 NOTES 1. ALL WIRES MARKED 1L1, 2L1, 1L2, ETC. ARE CUST OMER[...]

  • Page 7

    OPERA TION Important: NWHOSR/NWHSRG Circulation Heaters are equipped with INCOLOY ® heating elements and cast iron heating chambers (galvanized for the NWHSRG). It is the responsibility of the purchaser of the heater to know the chemical composition of the corrosive solution and the character of the materi- als entering the solution as well as the[...]

  • Page 8

    00-003 T A - U0 - ?K Litho in U.S.A. 2150 N. RULON WHITE BLVD., OGDEN, UT 84404 Phone: 1-800-368-2493 www.chromalox.com RENEW AL P AR TS IDENTIFICA TION Description Standard PCN Replacement Immersion Heater NWHOSR-06-04P5-E1 100108 156-304748-001 NWHOSR-06-04P5-E1 100116 156-304748-002 NWHOSR-06-005P-E1 100124 156-304748-003 NWHOSR-06-006P-E1 10013[...]