Go to page of
Similar user manuals
-
Blood Pressure Monitor
Citizen Systems CH-406D
12 pages 4.62 mb -
Blood Pressure Monitor
Citizen Systems CH-462E
12 pages 4.62 mb -
Blood Pressure Monitor
Citizen Systems CH-463E
12 pages 4.62 mb -
Blood Pressure Monitor
Citizen Systems CHU503
12 pages 1.96 mb -
Blood Pressure Monitor
Citizen Systems CH-302B
12 pages 4.62 mb -
Blood Pressure Monitor
Citizen Systems CH-437C
12 pages 4.62 mb -
Blood Pressure Monitor
Citizen Systems CT461C
12 pages 4.62 mb -
Blood Pressure Monitor
Citizen Systems CH-485E
12 pages 4.62 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Citizen Systems REF CH-311B, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Citizen Systems REF CH-311B one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Citizen Systems REF CH-311B. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Citizen Systems REF CH-311B should contain:
- informations concerning technical data of Citizen Systems REF CH-311B
- name of the manufacturer and a year of construction of the Citizen Systems REF CH-311B item
- rules of operation, control and maintenance of the Citizen Systems REF CH-311B item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Citizen Systems REF CH-311B alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Citizen Systems REF CH-311B, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Citizen Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Citizen Systems REF CH-311B.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Citizen Systems REF CH-311B item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
English - Eng 1 - INSTRUCTION MANUAL FOR DIGIT AL BLOOD PRESSURE MONITOR REF CH-311B 1301 English 6-1-12, Tanashi-cho, Nishi-Tokyo-shi, Tokyo 188-8511, Japan http://www.citizen-systems.co.jp/ E-mail: sales-oe@systems.citizen.co.jp Design and Specification are subject to change without notice. CITIZEN is a registered trade mark of Citizen Holdings C[...]
-
Page 2
- Eng 2 - - Eng 3 - English GENERAL REMARKS General remarks on blood pressure and blood pressure measurement 1. If the cuff is to be deflated quickly, depress “Exhaust button”. 2. The attached cuff is suited for an arm circumstance of 22 cm to 32 cm. 3. When attaching the cuff, the air hose should be placed on the inside of your arm on top of t[...]
-
Page 3
- Eng 4 - - Eng 5 - PRECAUTION FOR USE AND MAINTENANCE PRECAUTION FOR USE AND MAINTENANCE English Precaution for use 1. If you suffer from heart disease, high blood pressure or other circulatory disease, please consult your physician first. 2. If you feel abnormal pressure of the cuff during use or other irregularity, reduce the pressure immediatel[...]
-
Page 4
- Eng 7 - IDENTIFICATION OF PARTS - Eng 6 - PRECAUTION FOR USE AND MAINTENANCE Nature and frequency of maintenance: This product is designed for use over an extended period of time; however, it is generally recommended that it be inspected every two years to ensure proper function and performance. Protect the nature environment: Please help to prot[...]
-
Page 5
- Eng 9 - HOW TO LOAD BATTERIES English - Eng 8 - IDENTIFICATION OF PARTS Exhaust button Arm cuff Air hose plug Air hose 1 Open the battery compartment cover. 1 While pressing the lock section of the battery compartment cover, 2 pull the cover toward you to open. 2 Place the batteries in the compartment. Fit the batteries paying attention to the po[...]
-
Page 6
- Eng 11 - POINTS FOR ACCURATE MEASUREMENT English - Eng 10 - HOW TO UNLOAD THE BATTERIES Replacing the batteries • Replace the batteries with two new "AAA" batteries when appears on the display, or when nothing appears on the display when the POWER switch is pressed. • The memory is erased if the batteries are removed for replacement[...]
-
Page 7
- Eng 13 - HOW TO WRAP THE ARM CUFF English - Eng 12 - HOW TO WRAP THE ARM CUFF 1 Unroll the arm cuff. • When the arm cuff comes off, pass it through metal bar, directing the Velcro-attached side to the outer surface. 2 Put the arm cuff around your arm so that the air hose comes to the left palm side. • The arm cuff should be put on the bare ar[...]
-
Page 8
- Eng 15 - HOW TO MEASURE YOUR BLOOD PRESSURE English After all display marks are disappeared, the last measured systolic / diastolic blood pressure values and pulse rate are displayed. Memory function works on for approximately 2 second or during depressed the "POWER" switch. After memorized blood pressure value is disappeared, deflation[...]
-
Page 9
- Eng 17 - HOW TO MEASURE YOUR BLOOD PRESSURE English 4.3 Press the exhaust button Press the exhaust button valve to completely release the air in the cuff. 4.4 Power off Press the "POWER" switch to turn off. 4.5 Subsequent measurement For another measurement, just pressurize the cuff by pumping bulb. The time between two such Measurement[...]
-
Page 10
DISPLA Y MARK CONDITION/CA USE CORRECTIVE A CTION - Eng 19 - ABOUT “BLOOD PRESSURE” English - Eng 18 - ERROR INDICATIONS The cuff was not inflated to more than 30-40 mmHg above your systolic pressure. Raise the set pressure value by higher level. The cuff was inflated to more than 280 mmHg. Exhaust the air within the cuff. Appears when the bloo[...]
-
Page 11
- Eng 21 - BEFORE ASKING FOR REPAIR/INSPECTION English - Eng 20 - QUESTIONS AND ANSWERS ON BLOOD PRESSURE Q Why is the blood pressure measured at home different from that measured at the physician or a hospital? A Blood pressure may vary with exercising, ambient temperature or mental states. When you have a physician or nurse measure your blood pre[...]
-
Page 12
English - Eng 23 - - Eng 22 - SPECIFICATIONS ADDITIONAL INFORMATION CH-311B Oscillometric Method Soft cuff 22.0 to 32.0 cm 0 - 280 mmHg 40 - 180 Pulse / Min ±3 mmHg ±5% of reading Systolic Blood Pressure: 3 digits Diastolic Blood Pressure: 3 digits Pulse Rate: 3 digits Measuring: Exhaust: Re-Measure: Battery: "POWER" switch Manual Infla[...]