Citizen CH-656C manual

1
2
3
4
5
6
7
8
9
10
11
12
13

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Citizen CH-656C, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Citizen CH-656C one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Citizen CH-656C. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Citizen CH-656C should contain:
- informations concerning technical data of Citizen CH-656C
- name of the manufacturer and a year of construction of the Citizen CH-656C item
- rules of operation, control and maintenance of the Citizen CH-656C item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Citizen CH-656C alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Citizen CH-656C, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Citizen service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Citizen CH-656C.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Citizen CH-656C item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    English Español P ortuguês Deutch Italiano Français INSTRUCTION MANUAL FOR DIGIT AL BLOOD PRESSURE MONIT OR MODEL CH-656C - Eng 1 - M[...]

  • Page 2

    General Remarks on blood pressure measurement • If the cuff is to be deflated quickly , depress “POWER” switch. • The attached cuff is suited for a wrist circum- stance of 13.5cm to 19.5cm. • When attaching the cuff, the body of a blood pressure monitor should be placed on the in- side of your wrist. • Self measurement is no therapy! In[...]

  • Page 3

    English Español P ortuguês Deutch Italiano Français For proper measurement of blood pressure • T ake a deep breath five or six time and then relax before measuring blood pressure. If you are tense when taking the measurement, you will not get a valid reading. • Blood pressure will be elevated when you are in a worrisome or irritated state, s[...]

  • Page 4

    • Congestion, swelling, etc. may occur in some people. • If blood pressure is measured repeatedly , an accurate result will not be achieved. An inter - val of about 10 minutes should be allowed. • The memory is erased if the batteries are re- moved for replacement, etc. and a record should be kept of any necessary data. Precautions for mainte[...]

  • Page 5

    English Español P ortuguês Deutch Italiano Français - Eng 5 - Systolic blood pressure display section Diastolic blood pressure/ Pulse display section Wrist cuff Memory recall switch Power/Start switch Battry cover IDENTIFICA TION OF P AR TS M[...]

  • Page 6

    - Eng 6 - BA TTERY REPLACEMENT MEASUREMENT PROCEDURES 1. T o use this unit, you must install batteries, and also If battery mark “ ” will display on the display , you must change two pieces of batteries. 2. Open battery cover as illustrated. Replace the new two pieces of batteries, matching the (+) and (–) polarities on each battery with the [...]

  • Page 7

    English Español P ortuguês Deutch Italiano Français - Eng 7 - • Apply the wrist cuff to the wrist and make sure it is not too loose or too tight. If the wrist cuff is applied inappropriately , it may display an error or abnormal values. Pull the wrist tight and close the “Burr closure”. Wrist circumference: 13.5-19.5 cm. CA UTION Do not gr[...]

  • Page 8

    - Eng 8 - The heart symbol flashes, and the buzzer sounds for 1 second. Once the measurement prepara- tions are completed, the buzzer sounds three more times. If batteries become weak, “ ” mark is dis- played and measurement is discontinued. Pressurization and measuring start. When a pulse is detected, the pressure value moves to the lower side[...]

  • Page 9

    English Español P ortuguês Deutch Italiano Français - Eng 9 - When there are already 7 sets of results in memory , the oldest one is automatically erased and overwritten with the newest. (2 second) (1 second) Blood pressure values and pulse rate display al- ternatively on the display . Display of the mea- surement result will continue until powe[...]

  • Page 10

    - Eng 10 - 5. Memor y recall • Y ou can r ecall stored data by pressing the “Memory recall” switch, except when per- forming a measurement. • Up to 7 sets of measurement results can be stored in memory, and memory cell No. 1 is always used to store the newest set of re- sults. M • When pressing the “Memor y recall” switch, the memory [...]

  • Page 11

    English Español P ortuguês Deutch Italiano Français - Eng 11 - 6. Memor y clear function While the memory datum to be cleared are in- dicated and when the “Memory recall” switch is continued to push for 3 seconds, buzzer beeps and the memory datum are cleared. M[...]

  • Page 12

    - Eng 12 - DISPLA Y MARK CONDITION / CA USE CORRECTIVE A CTION The cuff was inflated to more than 280 mmHg. Pressurization is not possible Cuff winding has not been performed correctly . The pulse could not be measured ac- curately . The arm moved during measurement. Device has a trouble. Appears when the pulse could not be measured. Appears when t[...]

  • Page 13

    ● CITIZEN is a registered trademark of Citizen Watch Co., J apan. Consumer Electronics Division CBM Bldg. 5F , 5-68-10, Nakano, Nakano-ku, T okyo 164-0001, Japan Phone: (03)5345-7430 Fax: (03)5345-7431 E-mail: info-con@jcbm.co.jp[...]