Go to page of
Similar user manuals
-
Hot Beverage Maker
Cleveland Range KDL-60-T
2 pages 0.21 mb -
Hot Beverage Maker
Cleveland Range KDL-T
19 pages 1.08 mb -
Hot Beverage Maker
Cleveland Range KEL-40-T
29 pages 1.55 mb -
Hot Beverage Maker
Cleveland Range HA-MKGL-80-CC-T
47 pages 2.73 mb -
Hot Beverage Maker
Cleveland Range KGT-25
36 pages 1.06 mb -
Hot Beverage Maker
Cleveland Range KDP-60
2 pages 0.2 mb -
Hot Beverage Maker
Cleveland Range (T) MKDL-125-T (-CC)
55 pages 2.45 mb -
Hot Beverage Maker
Cleveland Range KGL-100, KGL-40-T
42 pages 1.72 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Cleveland Range KGL-80-T, KGL-40-SH, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cleveland Range KGL-80-T, KGL-40-SH one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Cleveland Range KGL-80-T, KGL-40-SH. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Cleveland Range KGL-80-T, KGL-40-SH should contain:
- informations concerning technical data of Cleveland Range KGL-80-T, KGL-40-SH
- name of the manufacturer and a year of construction of the Cleveland Range KGL-80-T, KGL-40-SH item
- rules of operation, control and maintenance of the Cleveland Range KGL-80-T, KGL-40-SH item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cleveland Range KGL-80-T, KGL-40-SH alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cleveland Range KGL-80-T, KGL-40-SH, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cleveland Range service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cleveland Range KGL-80-T, KGL-40-SH.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Cleveland Range KGL-80-T, KGL-40-SH item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Operators Manual Installation, Operation & Service Gas Floor Model Kettles MODELS : Stationary - KGL-40, KGL-60, KGL-80, KGL-100 Tilting - KGL-40-T , KGL-60-T , KGL-80-T Short Series - KGL-40-SH, KGL-60-SH, KGL-40-TSH KGL-40 KGL-40-T KGL-40SH SE95003-1 Rev . 1 1333 East 179th St., Cle v eland, Ohio , U .S .A. 44110 Phone: (216) 481-4900 F ax: ([...]
-
Page 2
FOR THE USER W ARNING : Improper installation, adjustment, alteration, ser vice or maintenance can cause proper ty damage, injury or death. Read the installation operating and maintenance instructions thoroughly bef ore installing or ser vicing this equipment. FOR YOUR SAFETY DO NO T ST ORE OR USE GASOLINE OR ANY O THER FLAMMABLE LIQUIDS AND V APOU[...]
-
Page 3
T ABLE OF CONTENTS Installation Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Shipping Damage Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 V entilation . . . . .[...]
-
Page 4
1 INSPECTION Before unpacking visually inspect the unit for evidence of damage during shipping. If damage is noticed, do not unpack the unit, follow shipping damage instructions. SHIPPING DAMAGE INSTRUCTIONS If shipping damage to the unit is discovered or suspected, observe the following guidelines in preparing a shipping damage claim. 1. Write dow[...]
-
Page 5
2 ELECTRICAL ENSURE THE ELECTRICAL SUPPL Y MA TCHES THE KETTLE'S REQUIREMENTS AS ST A TED ON THE RA TING LABEL. A cord and plug ar e supplied with the unit. Simply plug the unit into any grounded outlet rated for a minimum of 10 amps. The wiring diagram is located on the back of the console access panel. W ARNING: Electrical Grounding Instruct[...]
-
Page 6
3 Specification Drawing - Stationary , KGL-40, KGL-60, KGL-80, KGL-100 NO TES : Clev eland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the o wner and installer to comply with the codes. Installation of backflow pre venters, v acuum breakers and [...]
-
Page 7
4 Specification Drawing - Tilting, KGL-40-T , KGL-60-T , KGL-80-T NO TES : Clev eland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the o wner and installer to comply with the codes. Installation of backflow pre venters, v acuum breakers and other[...]
-
Page 8
5 Specification Drawing - Short Series, KGL-40-SH, KGL-60-SH, NO TES : Clev eland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the o wner and installer to comply with the codes. Installation of backflow pre venters, v acuum breakers and other spe[...]
-
Page 9
6 Specification Drawing - Short Series, KGL-40-TSH SPECIFICA TIONS NOTES FOO T LOCA TION & FLOOR DRAIN DET AIL FLANGED FOO T DET AIL 9/16" 14 mm 120º TYP 1" (25 mm) MAX. ADJUSTMENT 1 5/8" (42 mm) Ø 7/16" (11 mm) Ø 3 HOLES ON 3 1/8" (80 mm) Ø B.C.D. 4 7/8" 124 Ø mm NO TES : Clev eland Range reserves right of de[...]
-
Page 10
7 OPERA TING INSTRUCTIONS 3 4 5 2 1 7 5 8 10 9 6 ITEM # DESCRIPTION FUNCTION 1. Low W ater Indicator Light (Red) When lit, indicates that the kettle is low on water and will not operate in this condition (see RESERVOIR FILL PROCEDURES on page #28. 2. On-Off Switch/ T urns kettle ON/OFF and allows the operator to adjust the kettle Solid State temper[...]
-
Page 11
8 OPERA TING THE KETTLE DO NO T A TTEMPT T O OPERA TE THIS APPLIANCE DURING A PO WER F AILURE. KEEP APPLIANCE AND AREA FREE AND CLEAR OF COMBUSTIBLES. DO NO T LEAN ON OR PLA CE OBJECTS ON KETTLE LIP . SERIOUS INJUR Y COULD RESUL T IF KETTLE TIPPED O VER, SPILLING HOT CONTENTS. IF Y OU ARE COOKING AN EGG OR MILK PRODUCT , DO NO T PRE-HEA T KETTLE. 1[...]
-
Page 12
9 CARE AND CLEANING Y our kettle must be cleaned regularly to maintain its fast, efficient cooking performance, and to ensure its continued safe, r eliable operation. W ARNING: Do not use chloride base detergents. There is a gr owing number of non-chloride cleaners available. If unsure of the cleaners chlorine content consult the supplier . Also av[...]
-
Page 13
10 WRAP COVERS TO P LEFT SIDE FRONT RIGHT SIDE BACK KETTLE T OP FRONT LEFT SIDE RIGHT SIDE B A CK KGL-40 KE01479 -X KE53483-4 KE54253 -X KE01432 -X KE02186-1 KGL-60 KE01479-1 KE53483-5 KE54253-1 KE01432-1 KE02186-2 KGL-80 KE01479-2 KE53483-6 KE54253-2 KE01432-2 KE02186-3 KGL-100 KE01479-3 KE53483-7 KE54253-3 KE01432-3 KE02186-4 KGL-40-T KE01479 -X [...]
-
Page 14
11 PRESSURE RELIEF ASSEMBL Y 6 5 4 2 3 8 7 ITEM NO . P ART NO . DESCRIPTION QTY . PRESSURE RELIEF V AL VE ASSEMBLIES 1. KE01450 FOR ASME KETTLES (INCLUDES #2-6) 1 KE01450-1 FOR CE KETTLES (INCLUDES #2-6) 1 2. F A05049 MALE CONNECTOR, 1/2" PIPE - 1/4" TUBE 1 3. FI00151 STREET ELBOW , 90°, 1/2", BRASS 2 4. FI00178 TEE, 1/2" FPT ,[...]
-
Page 15
12 HINGE ASSEMBL Y 1 5 3 2 13 12 6 4 7 11 8 10 9 9 ITEM NO . P AR T NO . DESCRIPTION QTY . 1. - 11 SE00120-1 HINGE ASSEMBL Y - KGL-40/T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 SE00120-2 KGL-60/T , KGL-80/T , KGL-40-T/SH . . . . . . . . . . . . . . . .1 SE00120-3 KGL-100/T , KGL-60-T/SH . . . . . . . . . . . . . . . [...]
-
Page 16
13 ELECTRICAL COMPONENT BOX ITEM ON. P ART NO . DESCRIPTION QTY . KE01422 ELECTRICAL CONTROL BOX ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE53439 COMPONENT BOX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE53440 COVER, COMPONENT BOX . . . . . . . . . . . . . . . . . . . [...]
-
Page 17
14 3 4 5 6 2 For the following units with covers KGL-40-T KGL-60-T KGL-80-T For the following units with or with-out covers KGL-40-TSH For the following units with-out covers KGL-40 KGL-80 KGL-40-SH KGL-60 KGL-100 KGL-60-SH 1 TRUNNION ASSEMBL Y ITEM P ART DESCRIPTION QTY . NO . NO . 1. KE00354 TRUNNION BEARING ASSEMBL Y . . . . . .1 2. KE00351 TRUN[...]
-
Page 18
15 GAS CONTROL ASSEMBL Y 1 16 17 18 19 20 21 31 32 33 34 22 23 24 8 9 10 2 3 30 35 29 4 5 6 4 7 11 13 14 12 15 25 25 26 27 22 28 28 29 30 Stationary Models Tilting Models 34 Air Blower Primary Air Orifice Secondary Air Orifice Gas Orifice Ignitor Burner Gas Valve Shut-Off Valve[...]
-
Page 19
16 GAS CONTROL ASSEMBL Y ITEM ON. P ART NO . DESCRIPTION QTY . 1. KE53441 BLOWER, 115V , 60 HZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 KE53441-1 BLOWER, 220V , 50 HZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE54420 AIR INT AKE W ASHER[...]
-
Page 20
17 GEARBOX ASSEMBL Y 40 41 25 42 26 27 28 39 4 5 6 5 7 5 6 5 4 8 25 15 14 1 10 2 3 9 11 12 13 16 17 18 19 20 21 22 32 30 32 31 24 23 24 23 36 34 33 35 37 38[...]
-
Page 21
18 GEARBOX ASSEMBL Y ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE52836-2 TIL T SHAFT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE50315 WORM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. F A95005 TENSION PIN . . . . . . . . . . . . . . .[...]
-
Page 22
19 CONSOLE CONTROLS ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE50504 SWITCH, TOGGLE (USED PRIOR TO JANUARY 2000) . . . . . . . . . . . . . . . . . . .1 2. SK50062 RUBBER BOOT (USED PRIOR TO JANUARY 2000) . . . . . . . . . . . . . . . . . . . . .1 3. SE00114 POTENTIOMETER WITH ON/OFF SWITCH, C/W ITEM #4 . . . . . . . . . . . . . . . . .1 KE50988-2 [...]
-
Page 23
20 MAINTENANCE INSPECTION AND MAINTENANCE CHECKLIST Cleveland Range equipment requir es little preventative maintenance. W e do however pr ovide the following chart as a guideline for inspection and maintenance to keep your unit functioning at 100%. INSPECTION AND MAINTENANCE CHECKLIST The following check s should be completed eve r y six months or[...]
-
Page 24
21 KETTLE SAFETY INSPECTION CHECKLIST Regular inspection and maintenance of units is essential to obtain trouble fr ee and safe operation of equipment. Inspections must include testing of the pressur e relief valve and checks of the operating system to insure that it has not been alter ed. No safety features designed into the equipment should ever [...]
-
Page 25
22 SAFETY THERMOST A T : ✘ Probe removed partially ✘ Probe removed completely ✘ Thermostat electrically bypassed ✔ Probe fully inserted in tube Wiring is properly connected 12 3 Incorrect Installations 1 Safety thermostat probe is not completely inserted into tubing. 2 Safety thermostat probe is r emoved from tubing. 3 Safety thermostat ele[...]
-
Page 26
23 GENERAL 1. T o tur n the unit on, turn the switch to the on position. ■ Power is sent to primary side of the 120vac/16vac transformer . ■ Power is sent to the normally closed high limit. ■ From the high limit power is sent to the normally open contacts of the 12VDC relay and the L1 and L2 terminals of the ignition module. 2. From the secon[...]
-
Page 27
24 TROUBLESHOOTING GUIDES (continued) PROBLEM: KGL Kettle Won't Heat Does red light come on when unit is first turned on? Does red light go off shortly after unit is turned on? Yes Add water to jacket of Kettle. With the potentiometer set at 10, is 12 VDC at the coil of the relay? No Yes Is 16 VAC measured across Pins 9 and 10 on the controlle[...]
-
Page 28
25 TROUBLESHOOTING GUIDES (continued) PROBLEM: KGL Kettle Not Hot Enough With kettle pot empty and temperature knob set at 10, is the temperature of the surface of the pot 260 degrees? Unit is operating properly Yes When unit is cold (room temp) is the pressure gauge in the green? No Vent the kettle per instructions in the manual. No When the unit [...]
-
Page 29
26 TROUBLESHOOTING GUIDES (continued) PROBLEM: KGL Kettle Gets Too Hot With the kettle empty and the temperature set at 10, is the surface temp 260-265 degrees? The kettle is working properly. Yes Does the kettle continue to call for heat (green light stays on) when the kettle reaches 260-265 degrees? No Is there supply voltage to the coil of the g[...]
-
Page 30
KETTLE VENTING INSTRUCTIONS 1. Remove Access Panel from back of main kettle console. 2. T urn kettle ON and set temperature control to 10 , heat the empty kettle until unit cycles off. 3. V ent kettle by pulling V alve Ring eight to fifteen times, holding valve open for two seconds each time. NOTE : If unit cycles ON, stop venting and wait for kett[...]
-
Page 31
RESERVOIR FILL PROCEDURES The kettle's water level must be maintained at the proper level. Under normal operating conditions, the sealed water reservoir should never r equire the addition of water . If the red "low water" light comes on during use (while the kettle is in an upright position), the water level has reached a critically [...]
-
Page 32
29 PRESSURE RELIEF V AL VE PERIODIC TESTING Most insurance agencies requir e periodic testing of pressur e relief valves used on pr essure vessels. This procedur e will allow you to safely and quickly test your kettle's pressur e relief valve. W e recommend this test be perfor med twice a year . NOTE: The following instruction is intended for [...]
-
Page 33
3. Remove Console Cover and Access Panel. 4. Pull Pressur e Relief V alve Ring open to insur e vessel is not pressurized. 5. Remove 1/4" copper tubing and reducer bushing. 6. Remove Drain Plug cap and allow water to drain. 7. Replace Drain Plug cap and add water until it shows on sight glass. 8. Repeat steps 6 & 7 until water drains clear [...]
-
Page 34
31 GAS KETTLE ORIFICE REPLACEMENT Gas Orifice Console Cover "O" Ring Spring Plug 1. Remove Console Cover 2. Remove Plug and Spring 3. Remove Orifice 4. Replace with new Orifice and "O" ring 5. Replace Spring and Plug 6. Replace Console Cover Kettles BTU's per Gas W ater # of Hour T ype Column Orifices KGL-40, 140000 Natural[...]
-
Page 35
32 NOTE: Use thread sealant compatible with pr opane gas on all threaded piping connections. 1. Disconnect electrical connection. 2. Shut off main gas supply and disconnect kettle fr om supply line. 3. Remove main kettle CONSOLE CO VER . 4. Remove PLUG and SPRING . 5. Remove GAS ORIFICE and “O” RING . 6. Replace first with new “O” RING and [...]
-
Page 36
33 WIRING DIAGRAMS Diagram #1 : Floor Gas K ettle (except KGL-25/T) 110-120 V olts, 60Hz 1 2 3 4 5 7 13 14 15 17 18 19 20 16 6 9 11 10 8 KE90407-E[...]
-
Page 37
34 Diagram #1 (continued): Floor Gas K ettle (except KGL-25/T) 110-120 V olts, 60Hz ITEM NO . P ART NO . DESCRIPTION QTY . 1 KE55069-6 SAFETY THERMOST A T . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2 KE53436 AIR PRESSURE SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]
-
Page 38
35 Diagram #2 (see Diagram #1 f or common par ts): Floor Gas K ettle (except KGL-25/T) 200-240 V olts, 60Hz ITEM NO . P ART NO . DESCRIPTION QTY . 21 KE53838-2 TRANSFORMER 120-24V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 22 KE53441 BLOWER, 115V , 60 HZ . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]
-
Page 39
36 Diagram #3 (see Diagram #1 f or common par ts): Floor Gas K ettle (except KGL-25/T) 200-240 V olts, 50Hz ITEM NO . P ART NO . DESCRIPTION QTY . 23 KE53441-1 BLOWER, 220V , 50 HZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 24 KE53838-2 TRANSFORMER 120-24V . . . . . . . . . . . . . . . . . . . . . . . .[...]
-
Page 40
37 ON MARCHE ENCENDIDO ACCESO AN P AUSE, INTERRUPTION P AUSE, INTERRUPTION P AUSA, INTERRUPCION P AUSA, INTERRUZIONE P AUSE, UNTERBRECHUNG RESET RÉENCLENCHER RECONECT AR RESET NULLSTELLEN STOP OF ACTION ARRÊT DE L'ACTION P ARAR FUNCIONAMIENTO ARRESTO OPERAZIONE FUNKTION STOPPEN F AST STOP , EMERGENCY ARRÊT RAPIDE D'URGENCE P ARADA RAPI[...]
-
Page 41
38 LOW W A TER NIVEAU BAS DE L'EAU NIVEL DE AGUA BAJO LIVELLO BASSO W ASSERST AND NIEDRIG IGNITION F AILURE P ANNE D'ALLUMAGE F ALLO DE ENCENDIDO MANCA T A ACCENSIONE ZÜNDUNGSFEHLER COOLING REFROIDISSEMENT REFRIGERACION RAFFREDDAMENTO KÜHLUNG MIXER BRIDGE PONT DU MÉLANGEUR PUENTE DE MEZCLADORA MENSOLA MESCOLA TORE MISCHER-BRÜCKE RIGHT[...]
-
Page 42
SP ARE P ARTS LIST The following is a spare parts listing of parts that wear during nor mal us or are apt to be misplaced during normal operation. These par ts should be kept on hand to prevent loss time due to a minor problem. P ART NUMBER DESCRIPTION QUANTITY KE00458 KETTLE SOLID ST A TE CONTROL BOX . . . . . . . . . . . . . . . . . . . . . . . .[...]