Go to page of
Similar user manuals
-
Hot Beverage Maker
Cleveland Range KDP-100
2 pages 0.2 mb -
Hot Beverage Maker
Cleveland Range SD-760- K20
23 pages 1.05 mb -
Hot Beverage Maker
Cleveland Range KGL-100
42 pages 1.38 mb -
Hot Beverage Maker
Cleveland Range KDT- 3-T
18 pages 0.76 mb -
Hot Beverage Maker
Cleveland Range KEL-25-T
29 pages 1.55 mb -
Hot Beverage Maker
Cleveland Range KDL-150-T
2 pages 0.23 mb -
Hot Beverage Maker
Cleveland Range KDT-20-T
18 pages 0.76 mb -
Hot Beverage Maker
Cleveland Range KGL-80-T, KGL-40-SH
42 pages 1.72 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Cleveland Range KGT-25, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cleveland Range KGT-25 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Cleveland Range KGT-25. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Cleveland Range KGT-25 should contain:
- informations concerning technical data of Cleveland Range KGT-25
- name of the manufacturer and a year of construction of the Cleveland Range KGT-25 item
- rules of operation, control and maintenance of the Cleveland Range KGT-25 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cleveland Range KGT-25 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cleveland Range KGT-25, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cleveland Range service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cleveland Range KGT-25.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Cleveland Range KGT-25 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
SE95052 Operators Manual Installation, Operation & Service Gas 25 Gallon Kettle MODELS : KGL-25 KGL-25-T KGT -25-T KGT -25 1333 East 179th St., Cle v eland, Ohio , U .S .A. 44110 Phone: (216) 481-4900 F ax: (216) 481-3782 Visit our web site at www .cle v elandrange .com Enodis[...]
-
Page 2
FOR THE USER IMPOR T ANT POST IN A PROMINENT LOCA TION, INSTR UCTIONS T O BE FOLLO WED IN THE EVENT THE USER SMELLS GAS. THIS INFORMA TION SHALL BE OBT AINED BY CONSUL TING Y OUR LOCAL GAS SUPPLIER. KEEP APPLIANCE AREA FREE AND CLEAR FROM COMB USTIBLES . DO NO T OBSTR UCT THE FLO W OF COMBUSTION AND VENTILA TION AIR. ALL SER VICE MUST BE PERFORMED [...]
-
Page 3
T ABLE OF CONTENTS Installation Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Shipping Damage Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Clearance Requir ements [...]
-
Page 4
1 INSPECTION Before unpacking visually inspect the unit for evidence of damage during shipping. If damage is noticed, do not unpack the unit, follow shipping damage instructions. SHIPPING DAMAGE INSTRUCTIONS If shipping damage to the unit is discovered or suspected, observe the following guidelines in preparing a shipping damage claim. 1. Write dow[...]
-
Page 5
2 ELECTRICAL ENSURE THE ELECTRICAL SUPPL Y MA TCHES THE KETTLE'S REQUIREMENTS AS ST A TED ON THE RA TING LABEL. A cord and plug ar e supplied with the unit. Simply plug the unit into any grounded outlet rated for a minimum of 10 amps. See GENERAL ASSEMBL Y (pages #12-16) drawings for location of wiring diagram. W ARNING: Electrical Grounding I[...]
-
Page 6
3 SPECIFICA TIONS OVERALL DEPTH NOTES FOO T LOCA TION & FLOOR DRAIN DET AIL FLANGED FOO T DET AIL SPECIFICA TION DRA WING - TIL TING MODELS[...]
-
Page 7
4 SPECIFICA TIONS NOTES FOO T LOCA TION & FLOOR DRAIN DET AIL FLANGED FOO T DET AIL 9/16" 14 mm 120º TYP 1" (25 mm) MAX. ADJUSTMENT 1 5/8" (42 mm) Ø 7/16" (11 mm) Ø 3 HOLES ON 3 1/8" (80 mm) Ø B.C.D. 4 7/8" 124 Ø mm SPECIFICA TION DRA WING - ST A TIONAR Y MODELS[...]
-
Page 8
5 6 8 5 4 3 2 1 7 OPERA TING INSTRUCTIONS ITEM # DESCRIPTION FUNCTION 1. Tilt Wheel (tilting models only) Used for tilting the kettle. 2. V acuum/Pressure Gauge Indicate steam pressur e in PSI inside steam jacket as well as vacuum in inches of mercury . 3. Pressur e Relief V alve This valve is used to vent the kettle and in the unlikely event there[...]
-
Page 9
6 OPERA TING THE KETTLE DO NO T A TTEMPT T O OPERA TE THIS APPLIANCE DURING A PO WER F AILURE. KEEP APPLIANCE AND AREA FREE AND CLEAR OF COMBUSTIBLES. DO NO T LEAN ON OR PLACE OBJECTS ON KETTLE LIP . SERIOUS INJUR Y COULD RESUL T IF KETTLE TIPPED O VER, SPILLING HO T CONTENTS. 1. Before turning kettle on, read the V acuum/Pressure Gauge ( 2 ). The [...]
-
Page 10
CARE AND CLEANING Y our kettle must be cleaned regularly to maintain its fast, efficient cooking performance, and to ensure its continued safe, reliable operation. W ARNING: Do not use chloride base detergents. There is a gr owing number of non-chloride cleaners available. If unsure of the cleaners chlorine content consult the supplier . Also avoid[...]
-
Page 11
8 F AUCET ASSEMBL Y (optional) ITEM P ART DESCRIPTION QTY . NO . NO . 1. 3 3 / / 4 4 " " S S P P O O U U T T KE50825-7 FOR ST A TIONARY KETTLES . . . . . . . . . . .1 KE50825-2 FOR TIL TING KETTLES . . . . . . . . . . . . . . .1 2. F A95022 RET AINING RING . . . . . . . . . . . . . . . . . . . .1 3. F A05002-19 "O" RING . . . . [...]
-
Page 12
9 ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE01927-1 COMPONENT MOUNTING PLA TE (ST A TIONARY MODELS) . . . . . . . . . . . . . . .1 KE01927 COMPONENT MOUNTING PLA TE (TIL TING MODELS) . . . . . . . . . . . . . . . . . . .1 2. KE50753-7 RELA Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]
-
Page 13
10 ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE54897-1 MANIFOLD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE54890-1 IGNITION GUARD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. F A11144 SCREW . . . . . . . . . . . . . . . . . . [...]
-
Page 14
11 1 2 3 4 5 6 7 2" T ANGENT DRA W-OFF V AL VE ITEM NO . P ART NO . DESCRIPTION QTY . 1. - 7. KE50972-B DRA W-OFF ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1. F A95049 WING NUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2.[...]
-
Page 15
12 ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE00099 ADJUST ABLE FOOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 2. KE51723-1 SAFETY V AL VE (50 PSI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. KE50429-3 PRESSURE GAUGE . . . . . . . . . . . . . . . . . .[...]
-
Page 16
13 13. FI05198-5 COMPRESSION ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 14. FI00565-6 NIPPLE 3/8 NPT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 15. FI05222 SWIVEL ELBOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]
-
Page 17
14 23. F A19177 HEX SOCKET SET SCREW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 24. F A20047 JAM NUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 25. KE50294-1 MERCURY SWITCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]
-
Page 18
15 VIEW "A" COMPONENT MOUNTING BOX WITH LID REMOVED VIEW "B" MANIFOLD & BURNER TUBE PIPING DETAIL 1 22 5 31 21 7 8 10 6 L2 26 27 25 28 29 28 30 L3 7 9 14 15 16 10 L1 L4 32 2 3 17 24 23 25 18 19 20 4 B A 11 13 12 33 34 GENERAL ASSEMBL Y - ST A TIONAR Y MODELS (pg. 1 of 2)[...]
-
Page 19
16 ITEM NO . P ART NO . DESCRIPTION QTY . 1. KE00099 ADJUST ABLE FOOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 2. KE01928-2 COMPONENT MOUNTING PLA TE ASSEMBL Y . . . . . . . . . . . . . . . . . . . . . . . . .1 (see COMPONENT MOUNTING PLA TES on page #9) 3. F A20006 MACHINE SCREW NUT (10-24) . . .[...]
-
Page 20
17 CONSOLE CONTROLS ITEM NO . P ART NO . DESCRIPTION QTY . 1. SE00114 POTENTIOMETER WITH ON/OFF SWITCH, C/W ITEM #2 . . . . . . . . . . . . . . . . .1 2. KE51005 RUBBER BOOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 3. KE50569-1 KNOB, POTENTIOMETER . . . . . . . . . . . . . . . . . . . . . [...]
-
Page 21
18 HINGE ASSEMBL Y 1 5 3 2 13 12 6 4 7 11 8 10 9 9 ITEM NO . P ART NO . DESCRIPTION QTY . 1. - 11 SE00120-1 Hinge Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 1. KE50882 Hinge Base . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1[...]
-
Page 22
19 MAINTENANCE ALL SER VICE MUST BE PERFORMED BY A QU ALIFIED SER VICE TECHNICIAN. Cleveland Range equipment requir es little preventative maintenance. W e do however provide the following chart as a guideline for inspection and maintenance to keep your unit functioning at 100%. INSPECTION AND MAINTENANCE CHECKLIST The following check should be com[...]
-
Page 23
20 SAFETY INSPECTION CHECKLIST - TIL TING MODELS (pg. 1 of 2) Regular inspection and maintenance of units is essential to obtain trouble fr ee and safe operation of equipment. Inspections must include testing of the pressur e relief valve and checks of the operating system to insure that it has not been alter ed. No safety features designed into th[...]
-
Page 24
21 SAFETY THERMOST A T : ✘ Probe removed partially ✘ Probe removed completely ✘ Thermostat electrically bypassed ✔ Probe fully inserted in tube Wiring is properly connected 12 3 Incorrect Installations 1 Safety thermostat probe is not completely inserted into tubing. 2 Safety thermostat probe is r emoved from tubing. 3 Safety thermostat ele[...]
-
Page 25
22 LUBRICA TION PROCEDURE Lubricate the following parts ever y three months to insure smooth operation and r educe wear . TRUNNION HOUSING , WORM SCREW AND TIL T GEAR These parts are accessed through the top cover of the console. Apply grease to gear teeth. Check for excessive play and adjust with adjusting screw located on top of cross bar . KETTL[...]
-
Page 26
23 CALIBRA TING PROCEDURE 1. Insure the unit has a vacuum befor e you begin calibrating procedur es. If unit requir es venting refer to Kettle VENTING INSTRUCTIONS on page #26. 2. Set On-Off Switch/T emperature Control to " 10 " ( Max.). 3. Allow the unit to cycle twice. 4. Check temperature of the inner kettle surface with a digital surf[...]
-
Page 27
RESERVOIR FILL PROCEDURES The kettle's water level must be maintained at the proper level. Under normal operating conditions, the sealed water reservoir should never r equire the addition of water . If the red "low water" light comes on during use (while the kettle is in an upright position), the water level has reached a critically [...]
-
Page 28
25 Draining Procedur e 1. Shut off gas supply . 2. Disconnect gas line and electrical connection. 3. Remove bolts holding kettle to table. 4. Pull ring on pressur e relief valve to insur e there is no pressur e within the kettle jacket. 5. Remove sight glass. 6. Tilt kettle on its side (sight glass down) and allow to drain (pull ring on pressur e r[...]
-
Page 29
KETTLE VENTING INSTRUCTIONS 1. Remove guard bracket fr om pressur e relief valve/gauge assembly . 2. Set On-Off Switch/T emperature Control to t o " 10 " (Max.), heat the empty kettle until unit cycles off. 3. V ent kettle by pulling safety valve ring 8-10 times in short 2-3 second blasts with a 5 second interval between pulls. NOTE : If [...]
-
Page 30
27 WIRING DIAGRAM TABLE-TOP GAS KETTLE, 120-240 VOLTS KE90424-F[...]
-
Page 31
28 SEQUENCE OF OPERA TIONS 1. T o turn the unit on, turn the switch to the on position. ■ Power is sent to primary side of the 120vac/16vac transformer . ■ Power is sent to the normally closed high limit. ■ From the high limit power is sent to the normally open contacts of the 12VDC relay . 2. From the secondary of the transformer 16V AC is s[...]
-
Page 32
29 PROBLEM: KGL-25 Kettle Won't Heat Does red light come on when unit is first turned on? Does red light go off shortly after unit is turned on? Yes Add water to jacket of Kettle. With the potentiometer set at 10, is 12 VDC at the coil of the relay? No Yes Is 16 VAC measured across Pins 9 and 10 o n the contro ller? No Yes Is 16 VAC at the sec[...]
-
Page 33
30 PROBLEM: KGL-25 Kettle Not Hot Enough With kettle pot empty and temperat ure knob set at 10, is the temperature of th e surface of the pot 260 degrees? Unit is operating properly Yes When unit is cold (room temp) is th e pressure gauge in the green? No Vent the kettle per inst ructions in the manual. No When the unit is calling for heat (the gre[...]
-
Page 34
31 PROBLEM: KGL-25 Kettle Gets Too Hot With t he kettle empty and the temperature set at 10, is the surface temp 260-265 degrees? The kettle is wo rking properly. Yes Does the kettle continue to call for heat (green ligh t stays on) when the kettle reaches 260-265 degrees? No Is th ere 115 vac to the primary of the ignition transformer? No Replace [...]
-
Page 35
32 ON MARCHE ENCENDIDO ACCESO AN P AUSE, INTERRUPTION P AUSE, INTERRUPTION P AUSA, INTERRUPCION P AUSA, INTERRUZIONE P AUSE, UNTERBRECHUNG RESET RÉENCLENCHER RECONECT AR RESET NULLSTELLEN STOP OF ACTION ARRÊT DE L'ACTION P ARAR FUNCIONAMIENTO ARRESTO OPERAZIONE FUNKTION STOPPEN F AST STOP , EMERGENCY ARRÊT RAPIDE D'URGENCE P ARADA RAPI[...]
-
Page 36
33 LOW W A TER NIVEAU BAS DE L'EAU NIVEL DE AGUA BAJO LIVELLO BASSO W ASSERST AND NIEDRIG IGNITION F AILURE P ANNE D'ALLUMAGE F ALLO DE ENCENDIDO MANCA T A ACCENSIONE ZÜNDUNGSFEHLER COOLING REFROIDISSEMENT REFRIGERACION RAFFREDDAMENTO KÜHLUNG MIXER BRIDGE PONT DU MÉLANGEUR PUENTE DE MEZCLADORA MENSOLA MESCOLA TORE MISCHER-BRÜCKE RIGHT[...]