Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Cleveland Range OGB-6.20, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cleveland Range OGB-6.20 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Cleveland Range OGB-6.20. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Cleveland Range OGB-6.20 should contain:
- informations concerning technical data of Cleveland Range OGB-6.20
- name of the manufacturer and a year of construction of the Cleveland Range OGB-6.20 item
- rules of operation, control and maintenance of the Cleveland Range OGB-6.20 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cleveland Range OGB-6.20 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cleveland Range OGB-6.20, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cleveland Range service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cleveland Range OGB-6.20.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Cleveland Range OGB-6.20 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Ser vice & Par ts Manual Con v other m Combinat ion Ov en-Ste amer MODELS : Gas 10.10 and 6.20 OGB-10.10 OGS-10.10 OGB-6.20 OGS-6.20 0706 1333 East 179th St., Cleveland, Ohio, U.S.A. 441 10 Phone: (216) 481-4900 Fax: (216) 481-3782 Visit our web site at www .clevelandrange.com Enodis by[...]

  • Page 2

    T able of Contents Installation For the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 W arranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [...]

  • Page 3

    T able of Contents (continued) Service Parts Pump, Steam Generator , Gas, 1 10v (all models) . . . . . . . . . . . . . . . . . . . 54 (continued) Burner Insert, Steam Generator Natural Gas (OGB 6.20 & 10.10) . . . . 55 Burner Insert, HL, Pr emounted (all models) . . . . . . . . . . . . . . . . . . . . . . 56 Burner Insert, Air , LP & Natura[...]

  • Page 4

    NOTICE Post instructions to be followed if the user smell s gas. Display the instructions in a prominent locatio n. All users of this equipment mu st understand the in structions. Obtain the instructions from the local gas suppli er. Failure to follow the instructions if there is a gas leak can cause death, injury, and/or property damage. FOR THE I[...]

  • Page 5

    Cleveland STATEMENT OF POLICIES L I M I T E D W A R R A N T Y CLEVELAND RANGE products are warranted to t he original purchas er to be free from defe cts in materials and workmanship under normal use and service for t he standard warranty period of one year from date of installati on or 18 months from date of shipme n t, which ever comes first. CLE[...]

  • Page 6

    GENERAL INFORMATION ABOUT COMBIS A. PRODUCT INFORMATION Cleveland Range, LLC assigns t wo product identification numbers to each Combi: a model number and a serial number. The model num ber identifies the product characteristics. The serial numbe r identifies the individual Combi. 1. Model Number a. This manual covers the installation of the OEB an[...]

  • Page 7

    INSTALLATION INSTRUCTIONS A. GENERAL This equipment should be i nstalled only by qualified, professional plumbers, pipe fitters, and electricians. 1. The installation of this Combi must conform with: a. The National Fuel Gas Code, ANSI Z22 3.1 / NFPA 54 (latest edition), or the Natural Gas and Propane Installation Code CSA B1 49.1 as a pplicable. b[...]

  • Page 8

    B. INSTALLATION OF THE CO MBI – General Instructions General Instr uctions: 1. Select the Combi’s operating location. 2. Complete the water, drain, and electric lines before po sitioning and leveling the Combi. 3. Position and level the Combi. 4. Connect the utility lines after positioning and leveling the Combi. 5. Call Cleveland Range at 2 16[...]

  • Page 9

    C. SPECIAL INSTRUCTIONS FOR CASTER EQUIPPED COMBI STANDS AND COMBIS 1. Read all instructions before beginning i nstallation. 2. Level the floor if needed. 3. NOTE: Comb is on caster-equipped stands have less adjustment for level than adjustable foot equipped stands. 4. The front wheels of caster-equipped sta nds a nd Combis have locks. Check the ca[...]

  • Page 10

    1333 East 179th St., Cle veland, Ohio , U .S.A. 44110 Ph : 1-216-481-4900 Fx : 1-216-481-3782 Web Site : www .clev elandrange.com Cle veland Range, LLC SINCE 1922 INNO V A TIVE STEAM COOKING SOLUTIONS COMBI OVEN-STEAMER SECT . IIC P AGE 17 0406 Featuring the "Advanced Closed System + 3" by by b y Shor t Form Specifications I T E M N U [...]

  • Page 11

    NO TES : Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. SECT . IIC P AGE 18 0406 The "Advance[...]

  • Page 12

    1333 East 179th St., Cle veland, Ohio , U .S.A. 44110 Ph : 1-216-481-4900 Fx : 1-216-481-3782 Web Site : www .clev elandrange.com Cle veland Range, LLC SINCE 1922 INNO V A TIVE STEAM COOKING SOLUTIONS COMBI OVEN-STEAMER SECT . IIC P AGE 45 0406 Featuring the "Advanced Closed System + 3" by by b y Cooking Modes: ■ ■ Hot Air ■ ■ [...]

  • Page 13

    NO TES : Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. SECT . IIC P AGE 46 0406 W1 W2 D RC S CS A[...]

  • Page 14

    1333 East 179th St., Cle veland, Ohio , U .S.A. 44110 Ph : 1-216-481-4900 Fx : 1-216-481-3782 Web Site : www .clev elandrange.com Cle veland Range, LLC SINCE 1922 INNO V A TIVE STEAM COOKING SOLUTIONS COMBI OVEN-STEAMER SECT . IIC P AGE 21 0406 Featuring the "Advanced Closed System + 3" by by b y Short Form Specifications I T E M N U M[...]

  • Page 15

    NO TES : Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. SECT . IIC P AGE 22 0406 The "Advance[...]

  • Page 16

    1333 East 179th St., Cle veland, Ohio , U .S.A. 44110 Ph : 1-216-481-4900 Fx : 1-216-481-3782 Web Site : www .clev elandrange.com Cle veland Range, LLC SINCE 1922 INNO V A TIVE STEAM COOKING SOLUTIONS COMBI OVEN-STEAMER SECT . IIC P AGE 49 0406 Featuring the "Advanced Closed System + 3" by by b y Cooking Modes: ■ ■ Hot Air ■ ■ [...]

  • Page 17

    NO TES : Cleveland Range reserves right of design improvement or modification, as warranted. Many regional, state and local codes exist and it is the responsibility of the owner and installer to comply with the codes. Cleveland Range equipment is built to comply with applicable standards for manufacturers. SECT . IIC P AGE 50 0406 W1 W2 D RC S CS A[...]

  • Page 18

    Figure 4-1a Control Pa nel CONTROL PANEL BASIC OPERATION A. QUICK START GUIDE ALWAYS PRE-HEAT THE OVEN CHAMBER! 1. Switch on with key (1). 2. Select cooking mode with keys (2-5). 3. Press key (6) to start. OR 1. Press key (18) and rotate Selector Dial (23) to set oven temperature. 2. Press key (19) and rotate Selector Dial (23) to set cooking time.[...]

  • Page 19

    Figure 4-1b Control Pa nel B. CONTROL PANEL DETAIL VIEW Note: Item numbers correspond to numbers on the control panels in Figure 4-1b 1. ON/OFF When the Combi is turned ON: • Self-diagnosis is performed. • Oven light turns on. • Steam generator fills and heats (OEB and OGB models). Cooking Modes 2. Steam • Oven temperature is continuou sly [...]

  • Page 20

    Function Indicators • Light up when function or activity is engaged: 10. Reduced Power 11. Burner or Electric Heating ON 12. Reduced Fan Speed 13. Cooking Mode Engaged 14. Button Lock 15. Crisp & Tasty Engaged 16. Program Protection 17. Display • Display in normal mode : • Date. • Time. • Oven Temperature. • Cooking Tim e • Core P[...]

  • Page 21

    CAUTION Clean the oven chamber at least once per day or more frequently as needed Failure to clean the Combi properly and regularly can cause equipment damage. Dama g e caused b y im p ro p er cleanin g will invalidate the Warrant y ! AT THE END OF TH E DAY OR SHIFT A. Cleaning the Oven Chamber 1. Cleaning – General a. Regular cleaning of the Com[...]

  • Page 22

    CAUTION Do NOT use U-Shaped racks that are bent or otherw ise damaged in any way. Pans and accessories plac ed in damaged racks can tip an d spill, causing burns, injur ies and/or equip ment damage 3. Manual Cleaning of the Ov en Chamber a. Clean the Combi daily to prevent discolor ation and corrosion of the stainle ss steel. 1) Avoid scratching th[...]

  • Page 23

    Drain Cover and Drain e. Clean the Bypass Measuring Aperture. (Openi ng in the oven chamber on the left-hand side, slightly below the d oor latch. See diagram.) 1) Spray with CONVOClean. 2) Rinse clean with the hand shower. f. Remove and clean the drai n cover. 1) Clean food residue and dri ppings from the tray and drain in the oven chamber. 2) Spr[...]

  • Page 24

    B. Semi-Automatic Cleani ng of the Oven Chamber NOTE: Do NOT press the Start/Stop key w hile using the Semi-automatic Cleaning process. This stops the cleaning process. 1. Before starting the Semi-Automatic Cleaning process, make sure the oven chamber is below 158°F by stopping all proc esses and pressing the Temperature key twice to view the actu[...]

  • Page 25

    a. The third step is Steam mode at 86°F for 1 minute. No action is n eeded. b. The fourth step is Steam at 212°F for 10 minutes, followed by a Signal Ton e. 15. Turn OFF the Combi when the Signal Tone sounds. 16. Use the hand shower to rinse thoroughly the oven chamber, accessories, and behind the fan g uard. 17. In the case of severe staining or[...]

  • Page 26

    CAUTION Always make sure the cleaning age n t containers are correctly connected to the Combi CONVOClean => RED CONVOCare => BLUE or WHITE C. CONVOClean Automatic Cl eaning System (optional): NOTES: • Do NOT interrupt the automatic cleaning process. Interrupting and restarting the Automatic Cleaning System with the ON/OFF key may start a 6 [...]

  • Page 27

    3 “Strong Soiling” 2 hours. 4 ‘Strong Soiling – Shining+” 2 hours and 45 minutes. 8. Press the Smart Key. 9. “Food inside oven?” appe ars in the display. 10. If the oven is empt y, then answer “No.” 11. Confirm by pressing the Smart Key. 12. “Start auto-cleaning?” appears in the display. 13. Answer “Yes.” 14. Confirm by pr[...]

  • Page 28

    CAUTION Use ONLY the DISSOLVE ® Descaler method using Part No. 106174 to descale the Combi. Read, understand, and follow both the descaling pr ocedure instructions and warnings, and the instructions and warnings on the DISSOLVE ® labe l and MSDS. Injury, equipment damage, and property damage can result from using other descaling systems and/or fa[...]

  • Page 29

    WARNING This procedure is s lightly different depending on the model being descaled. This ent ire procedure should be read and full y understand as it applies to the model being descaled, before be g innin g the actual descalin g o p eration. B. GENERAL SAFETY FOR DESCALING 1. Always wear suitable protective clothing including appropriate gloves, a[...]

  • Page 30

    • While adding liquid to the steam generat or through the descaler inlets, pour slowly to avoid overflow. • Wipe up any spills at once to avoid etching. 6. After the automatic fill cycle has ended, tu rn OFF the Combi with the ON/OFF key, and at the Control Power Service Disconnect switch locate d below the hand shower. See Figure 6-2. 7. Add c[...]

  • Page 31

    C3216313 B 0706 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Ohio 44110-2574 T HIS DESIGN DESCRIBES A PROPRIE T ARY ITEM AND IS THE PROPERT Y OF CLEVELAND RANGE. THIS DRAWING IS NOT TO BE COPIED OR USED WITHOU T THE APPROV A L OF CLEVELAND RANGE. T OLERANCES (UNLESS OTHERWISE N OTED) D O NOT SCALE PRINTED DRAWING DRAWN BY D ATE T ITLE REV S[...]

  • Page 32

    C3216313 B 0706 I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2115483 ASSEMBL Y , P ANEL, RIGHT SIDE, 10.10 2 1 C2114824 ASSEMBL Y/WELDMENT , INTERMEDIA TE TOP , 6.10/10.10 3 1 C2115490 ASSEMBL Y , CORNER, FRONT , RIGHT , 10.10/10.20 4 1 C2114452 WELDMENT , F ACE PLA TE, LOWER, 6.10/10.10 5[...]

  • Page 33

    C3216313 B 0706 CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Ohio 44110-2574 THIS DESIGN DESCRIB ES A PROPRIE TARY ITEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DRAWING IS NO T T O BE COP IED OR USED WITHOUT THE APPROVA L OF CLEVELAND RANGE. T OLERANCES ( UNLESS OTHERWISE N OTED) DO NOT SCALE PRINTED DRAWING D RAWN BY D ATE TITLE REV SH[...]

  • Page 34

    C3216313 B 0706 I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2115483 ASSEMBL Y , P ANEL, RIGHT SIDE, 10.10 2 1 C2114824 ASSEMBL Y/WELDMENT , INTERMEDIA TE TOP , 6.10/10.10 3 1 C2115490 ASSEMBL Y , CORNER, FRONT , RIGHT , 10.10/10.20 4 1 C2114452 WELDMENT , F ACE PLA TE, LOWER, 6.10/10.10 5[...]

  • Page 35

    C3216313 B 0706 CLEVELAND RANGE, LLC 1 333 East 179th St., Cleveland, Ohio 441 10 -2574 T HIS DESIGN DESCRIB ES A PR OPRIETARY ITE M AN D IS THE PROPER T Y O F C LEVELAND RANGE. THIS DRAWING IS NOT T O B E COPIED OR USED WITHOU T THE APPR OVAL OF CLEVELAND RANGE. T OLERANCES (UNLESS OTH ERW ISE NOTED) D O NOT SCALE P RINTE D DR AWING DRAWN BY D ATE[...]

  • Page 36

    C3216313 B 0706 I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2115482 ASSEMBL Y , P ANEL, RIGHT SIDE, 6.20 2 1 C2114826 ASSEMBL Y/WELDMENT , INTERMEDIA TE TOP , 6.20/10.20 3 1 C2115489 ASSEMBL Y , CORNER, FRONT , RIGHT , 6.20 4 1 C2114453 WELDMENT , F ACEPLA TE, LOWER, 6.20/10.20 5 1 C21146[...]

  • Page 37

    C3216313 B 0706 C LEVELAND RANGE, LLC 1 333 Eas t 179 th St., Cleveland, Ohio 44110-2574 T HIS DESIGN DESCRI BES A PROPRIETARY ITEM AND IS THE PRO PERTY OF CL EVELAND RANGE. T HIS DRAWING IS NO T T O BE COPIED OR USE D W ITHOUT THE APPRO V AL OF CLEVELAND RANGE. T OLERANCES (UNLESS OTHERWISE N OTE D) D O NOT SCALE P RINTED DRAWING DRAWN BY D ATE T [...]

  • Page 38

    C3216313 B 0706 I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2115482 ASSEMBL Y , P ANEL, RIGHT SIDE, 6.20 2 1 C2114826 ASSEMBL Y/WELDMENT , INTERMEDIA TE TOP , 6.20/10.20 3 1 C2115489 ASSEMBL Y , CORNER, FRONT , RIGHT , 6.20 4 1 C2114453 WELDMENT , F ACEPLA TE, LOWER, 6.20/10.20 5 1 C21146[...]

  • Page 39

    300480 C 0706 COMPONENT P ANEL ASSEMBL Y , Gas OGB 6.20 & 10.10 MODELS CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Ohio 44 11 0-2574 THIS DESIGN DESCRIBES A PROPRIETAR Y I TEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT TH E APPROVAL OF CLEVELAND RANGE. TOL ERANCES (UNLESS OTHERWISE NOTED) D[...]

  • Page 40

    300480 C 0706 COMPONENT P ANEL ASSEMBL Y , GAS OGB 6.20 & 10.10 MODELS I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 2 300419 TRANSFORMER, 24V 2 1 111603 DIN RAIL 3.25" 3 2 111601 DIN RAIL 8.375" 4 1 111526 PLA TE, ADAPTER, A.C. DRIVE 5 1 300412 AC DRIVE (6.20-10.10) 6 1 300413 L[...]

  • Page 41

    300488 C 0706 COMPONENT P ANEL ASSEMBL Y , GAS OGS 6.20 & 10.10 MODELS CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Ohio 44 11 0-2574 THIS DESIGN DESCRIBES A PROPRIETAR Y I TEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DRAWING IS NOT TO BE COPIED OR USED WITHOUT TH E APPROVAL OF CLEVELAND RANGE. TOL ERANCES (UNLESS OTHERWISE NOTED) D[...]

  • Page 42

    300488 C 0706 COMPONENT P ANEL ASSEMBL Y , GAS OGS 6.20 & 10.10 MODELS I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 300419 TRANSFORMER, 24V 2 1 111603 DIN RAIL 3.25" 3 2 111601 DIN RAIL 8.375" 4 1 111526 PLA TE, ADAPTER, A.C. DRIVE (NOT SHOWN) 5 1 300412 AC DRIVE (6.20-10.10) [...]

  • Page 43

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2114297 WELDMENT , CONTROL P ANEL 2 1 C5019101 CONTROLLER, 5010 OPERA TING MODULE 3 1 C5019105 CONTROLLER, 5010 PICTOMODULE PICTO 4 1 C5009313 LA TCH ROCKER 5 1 C5009314 KNOB, SELECTOR, COMBI 6 10 C8009030 SP ACER, CONTROL P ANEL 7 1 C7011010 GA[...]

  • Page 44

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 32 1 C5016002 LOCKNUT M25 31 1 C700106607000-1 EDGE PROTECTOR, CUT 7.000" 30 1 C700106607000 EDGE PROTECTOR, CUT 7.000" 22 1 C2010066 CONNECTION, GAS, SINGLE 3/4" 20 1 C5016001 FITTING, ELECTRICAL, LIQUID TIGHT 19 1 C2016147 CONDENSER [...]

  • Page 45

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2114520 OUTER BASE, EL, 6.10/10.10 2 1 C2216088 AIR INLET BOX FINAL ASSEMBL Y 3 1 C5011003 CONNECTION FLANGE 4 5 C8006058 SCHNORR LOCK W ASHER 5 4 C8003035 HEXAGON BOL T M5X10 7 1 C70016603000 EDGE PROTECTOR, CUT 3.000 8 1 C6005021 RUBBER BUSHIN[...]

  • Page 46

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2114542 ASSEMBL Y , OUTER BASE, GAS, STEAM GEN, 6.20/10.20 2 1 C2114699 ASSEMBL Y , TOP COVER, PUMP HOUSING, AUTO CLEAN SYSTEM 3 1 C2616451 BOTTOM FLAP , PUMP HOUSING, GAS, 6.20, 110V 4 1 C2016147 CONDENSER HOSE ASSY , GAS 5 1 C2010068 DOUBLE GA[...]

  • Page 47

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2114542 ASSEMBL Y , OUTER BASE, GAS, STEAM GEN, 6.20/10.20 2 1 C2016147 CONDENSER HOSE ASSY , GAS 3 1 C2010068 DOUBLE GAS CONNECTION R 3/4" 5 1 C5011003 CONNECTION FLANGE 7 5 C8006058 SCHNORR LOCK W ASHER 8 2 C8003035 HEXAGON BOL T M5X10 9 [...]

  • Page 48

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2114522 ASSEMBL Y , OUTER PLA TE EL 6.20/10.20 2 1 C2114699 ASSEMBL Y , TOP COVER, PUMP HOUSING, AUTO CLEAN SYSTEM 3 1 C2016127 ASSY , WA TER V AL VE, GAS, 6.20 5 1 C5011003 CONNECTION FLANGE 8 2 111538 ADAPTER, 3/4-14 BSPP FEMALE X 3/4 GHT MALE[...]

  • Page 49

    [...]

  • Page 50

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C6015215 ELBOW , HOSE CONNECTION, 3/8" WITH SEAL 2 2 111647 CLAMP , OETIKER, S/S, 19/32" 3 1 11149811000 HOSE, SILICONE, 3/8" ID X 11.000 4 1 300455 V AL VE ASSEMBL Y , 1 W A Y , 120 V AC 5 1 300407 FIL TER, ELECTRICAL 6 2 300509 T[...]

  • Page 51

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 3 300407 FIL TER, ELECTRICAL 2 6 300509 TERMINAL, 18-22 A WG PIGGY BACK 3 4 111498 HOSE, SILICONE, 3/8" ID (SPECIFY LENGTH) 4 7 111647 CLAMP , OETIKER, S/S, 19/32" 5 1 C5001085 PRESSURE REGULA TING V AL VE ODGAS 6 2 C6015401 BARB, 1/2 R X[...]

  • Page 52

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 3 300407 FIL TER, ELECTRICAL 2 6 300509 TERMINAL, 18-22 A WG PIGGY BACK 3 4 111498 HOSE, SILICONE, 3/8" ID (SPECIFY LENGTH) 4 7 111647 CLAMP , OETIKER, S/S, 19/32" 5 1 C5001085 PRESSURE REGULA TING V AL VE ODGAS 6 2 C6015401 BARB, 1/2 R X[...]

  • Page 53

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 300456 V AL VE ASSY . 2 WA Y 120V AC 2 4 111498 HOSE, SILICONE, 3/8" ID (SPECIFY LENGTH) 3 2 C6015401 BARB, 1/2 R X 3/8 HOSE 4 1 C5001085 PRESSURE REGULA TING V AL VE OD GAS 5 1 C6006140 GAUGE, 60 PSI BOTTOM MOUNT 6 6 111647 CLAMP , OETIKER,[...]

  • Page 54

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 300453 V AL VE ASSEMBL Y , 3W A Y 240V AC 300363 TRIPLE SOLENOID V AL VE 110-120V 50/60 Hz 180º 2 5 111498 HOSE, SILICONE, 3/8" ID (SPECIFY LENGTH) 3 6 111647 CLAMP , OETIKER, S/S, 19/32" 4 1 111646 TEE, BRASS, 3/8" BRASS CLEVELAN[...]

  • Page 55

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 300456 V AL VE ASSY . 2 WA Y 120V AC 2 2 111498 HOSE, SILICONE, 3/8" ID (SPECIFY LENGTH) 3 2 111647 CLAMP , OETIKER, S/S, 19/32" 4 2 300407 FIL TER, ELECTRICAL 5 4 300509 TERMINAL, 18-22 A WG PIGGY BACK 4 3 2 5 2 1 C2016126 A 0706 ASSEM[...]

  • Page 56

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 300363 TRIPLE SOLENOID V AL VE 110-120V 50/60 Hz 180º (OGS 6.20) 2 3 300407 FIL TER, ELECTRICAL 3 6 300509 TERMINAL, 18-22 A WG PIGGY BACK 4 5 111498 HOSE, SILICONE, 3/8" ID (SPECIFY LENGTH) 5 10 111647 CLAMP , OETIKER, S/S, 19/32" 6 1[...]

  • Page 57

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2314891 WELDMENT , GEN GAS 6.20 (NOT SHOWN) 2 1 C2314243 SUPPORT , STEAM GEN, T ABLE TOP UNIT 3 1 C5016006 THERMOCOUPLE, SENSOR, OSC/OSP , 64.960" (1650MM) 4 1 C2314991 PUMP , 110V , GAS STEAM GENERA TOR 5 1 C5019003 ASSEMBL Y , DOUBLE LEVE[...]

  • Page 58

    CLEVELAND RANGE, LLC 1333 East 179th St., Cleveland, Ohio 441 10-2574 THIS DESIGN DES CRIBES A PROPRIE TAR Y ITEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DRAWING IS NO T T O BE COPIED OR USED WITHOUT THE APPROV A L OF CLEVELAND RANGE. T OLERANCES (UNLESS OTHERWISE NOTED) DO NOT SCALE PRINTED DRAWING DRAWN BY D AT E TITLE REV SHEET OF DRAWING N[...]

  • Page 59

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2010045 BURNER INSERT GEN STEAM 6.10/6.20/10.10 WELDED 2 1 C6015032 SEAL, BURNER ø 50 MM 3 1 C2615351 RESTRICTION FLANGE ø 210 RG128 4 1 C2010014 BURNER, ø 50 x150, 20 KW 5 1 C2614907 CLAMPING FLANGE, STEAM GENERA TOR, BURNER, ø 50 6 1 C4018[...]

  • Page 60

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2010050 BURNER INSERT HL, 6.10/6.20, WELDMENT 1 C2010052 BURNER INSERT , HL, 10.10/20.10, WELDMENT 2 1 C4018002 AUTO-IGNITION ELECTRODE 3 1 C4018000 MONITORING ELECTRODE 4 1 C5015004 INSPECTION GLASS, BURNER 5 1 C2614845 COVER, INSPECTION GLASS,[...]

  • Page 61

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2616521 BURNER INSERT , HL, PRE-MOUNTED, 6.10/6.20 1 C2616522 BURNER INSERT , HL, PRE-ASSEMBLED, 10.10/20.10 2 2 C6015034 SEAL, F AN RG128/148 3 1 C5018006 BURNER BLOWER, RG128, 110V 4 1 C6016009 GAS V AL VE, HONEYWELL, 110V 5 1 C6016030 SEALING[...]

  • Page 62

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2514358 ASSEMBL Y , OUTER DOOR, 6.20 1 C2514359 ASSEMBL Y , OUTER DOOR, 10.10 2 1 C2514389 ASSEMBL Y , INNER DOOR, 6.20 1 C2514390 ASSEMBL Y , INNER DOOR, 10.10 3 1 C6012000 DOOR HANDLE, LOCKING 4 1 C6009016 PLASTIC LETTER "C" RED 5 2 [...]

  • Page 63

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2614806 CARRIAGE PLA TE, WELDED, 6.20 C2614807 CARRIAGE PLA TE, WELDED, 10.10 & 10.20 C2614809 CARRIAGE PLA TE, WELDED, 20.10 & 20.20 2 2 C6012002 ASSEMBLED,GUIDE ROLLER RST CPL 3 2 C6012005 DISC ø 39 x 6 RST 4 2 C2014008 LOCKING BLOCK,[...]

  • Page 64

    A E D D E B C INSTALLED ORIENTATION SECTION E-E DETAIL C DETAIL B DETAIL A SECTION D-D 4 1 19 20 8 14 7 21 13 21 4 2 16 1 8 20 11 21 10 17 17 22 14 21 3 9 6 15 5 8 14 4 18 C2614801 B, C2614802 B & C2614804 P1 0706 SLIDING PLA TE, COMPLETE ALL 6.20 & 10.10 MODELS Page 2 of 2 60[...]

  • Page 65

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C2514351 DOOR, 6.20, COMPLETE - 1 C2514352 DOOR, 10.10, COMPLETE 2 1 C2114652 WELDMENT , CORNER, FRONT LEFT , 6.20 - 1 C2114653 WELDMENT , CORNER, FRONT LEFT , 10.10 3 1 C2114782 P ANEL ASSY , LEFT , OGB 6.20, OGS 6.20, OEB 6.20, OES 6.20 - 1 C21[...]

  • Page 66

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C3216201 WELDMENT , ST AND, COMBI, 6.10/10.10 2 2 100413 FOOT ASS'Y , ADJUST ABLE (FOR 1.250 SQ. TUBING), ANCHORABLE TIEDOWN 3 1 C3216245 WELDMENT , ST AND DOOR, 6.10/10.10, LEFT SIDE 4 1 C3216249 WELDMENT , ST AND DOOR, 6.10/10.10, RIGHT SI[...]

  • Page 67

    [...]

  • Page 68

    [...]

  • Page 69

    [...]

  • Page 70

    [...]

  • Page 71

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1 1 C3416377 WELDMENT , BASE, ST ACKING KIT , GAS, 6.20/10.20 2 1 C3416369 WELDMENT , EXHAUST SHIELD, ST ACKING KIT , GAS 3 1 C3416363 SHROUD, ST ACKING KIT , GAS, 6.20 1 C3416361 SHROUD, ST ACKING KIT , GAS, 6.10 4 1 C2016200 PIPE, STEAM EXHAUST , G[...]

  • Page 72

    I I T T E E M M Q Q T T Y Y P P A A R R T T N N 0 0 . . D D E E S S C C R R I I P P T T I I O O N N 1* 1 C3416368 WELDMENT , BASE, ST ACKING KIT , ELECTRIC, 6.10/10.10 2* 1 C3416362 SHROUD, ST ACKING KIT , ELECTRIC, X.10 3* 1 C3416365 BRACKET , STEAM EXHAUST PIPE, ST ACKING KIT , ELECTRIC 4* 1 C2016201 PIPE, STEAM EXHAUST , ELECTRIC, ST ACKING KIT [...]

  • Page 73

    CLEVELAND RANGE OGB 6.20/10.10 SEQUENCE OF OPERATIONS When using these instructions refer to the OGB 6.20/10.10 wiring schematic. 1 When 120 VAC is applied to the combi, it is sent through the line filter (Z1) to the Power Control Switch (S1). 2 When the Power Control Switch (S1) is closed a The red light in the switch is energized. b 120 VAC is se[...]

  • Page 74

    • 120 VAC is sent from terminal 1 of connector X13 on the Control Board (A10) to the Generator Pump (M4). • As the water level drops below the probes the f ill solenoid (Y3) will energize. This rocking of the water will h elp flush scale from the generator. • Then the pump will be energized again • When the condensate box is heated to 140 d[...]

  • Page 75

    a The front display will include a lighted bar under the steam symbol • When the heat circuit is energized the h eat symbol will be energized • The cooking mode symbol will be energized. • The time display will invert and begin to count down. b The fan circuit is energized by the Control Board (A10) transm itting and receiving a signal from t[...]

  • Page 76

    5 With the combi in the Hot Air mode with time on the timer, the door closed and the start switch is depressed b The front display will include a li ghted bar under the Hot Air symbol • When the heat circuit is energized the h eat symbol will be energized • The cooking mode symbol will be energized. • The time display will invert and begin to[...]

  • Page 77

    f The heat circuit will remain energized until th e cabinet set temperature is reached g When the condensate box is heated to 140 degrees F at the B3probe, 120 VAC is sent from terminal 5 of connector X 12 to the condenser valve (Y1) until the temperature drops. h If the “Crisp and Tasty” mode is selected • 120 VAC is sent from terminal 6 of [...]

  • Page 78

    ◊ When this speed is attained the signal is sent from term inal 2 of connector X2 on the Steam Power Burner and Fa n Control (U21) to term inal 9 of connector X24 on the Gas Board (A20) • A request for heat is sent from termin al 3 of connector X21 on the Gas Board (A20) to terminal 10 on connector X1 on the Steam Burner Control Module (N21) ?[...]

  • Page 79

    ◊ In the full mode (3 drops in the disp lay) the Y2 valve will be energized continuously. h When the timer counts to 0 or the core tem p probe (B10) reaches the set amount the cycle ends and the steam generator reverts to the standby tem perature of 190- degree F. 6 With the combi in the Rethermalization m ode with time on the timer, the door clo[...]

  • Page 80

    • A signal is sent from terminal 2 of connector X24 on the Gas Board (A20) to terminal 4 of connector X2 on the Hot Air Power Burner and Fan Control (U20) selecting the set speed of the combustion blower. ◊ When this speed is attained the signal is sent from term inal 2 of connector X2 on the Hot Air Power Burner and Fan Control (U20) to termin[...]

  • Page 81

    CLEVELAND RANGE, LLC 1333 East 179th S t., Cleveland, Ohio 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWING NO. THIS DES IGN DESCRIBES A PROPRIETAR Y ITEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DR AWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE. TITLE SIZE B WIRING DIAGRAM OGB 6.20/10 .10 3004[...]

  • Page 82

    -M1 M 3~ W2/YE U1/B K GND 20 -X10 POWER SUPPLY 12VDC 96-264V AC 12V DC 1 L1 GND FAN 2 3 N BK 12 BU 12 30 -X10 BK 12 -F1.1 2A 1 2 -X10 31 RD 18 L N RD 18 -A10:X12: 1 /3.D6 0V 12V BU 18 BU 18 RD 18 RD 18 /4.E3 -A20:X28 :2 /3.D4 -A10:X10:4 /3.D4 -A10:X10 :3 /4.E3 -A20:X28 :1 BU 18 2 1 -F10 15A BK 18 GN 18 -U10 L2 L1 12V RxD TxD COM V U GND W P1 P2 /4.[...]

  • Page 83

    M M SM 5010 -M3.1 -Y1 -F2.1 -A10 -X10 -M4 -X10 -S7 -S2 -X10 -Y10 -Y20 -Y22 -Y23 /2.E3 -G1:12V /2.E3 -G1: 0V /2.C4 -X10: 31 1 2 345 6 7891 0 1 1 1 2 1 2 3 4567 81 2 3 4 5 6 7 1 14 13 12 11 10 5 7 9 86 3 4 2 1 10 9 876 1 543 2 10 12 11 9 876 1 543 2 10 9 876 1 543 2 10 9 8 7 6 3 1 2 4 5 X14: X11: X15: X16: X10: X19: X17: X18: BU 18 BU 18 RD 18 RD 18 [...]

  • Page 84

    1 2 3 4 5 6 7 8 9 10 11 12 X27: X26: X25: X24: X23: 87 6 54 32 1 7 84 5 62 31 7 84 5 62 31 4 65 1 32 12 10 9 11 11 12 9 10 4 9 8 6 57 13 2 18 23 4 7 6 5 91 0 2 1 9 5 4 36 7 8 9 8 5 7 6 4 3 2 1 X22: X28: -X10 X21: 42 43 41 40 -X10 -X10 46 /6.C3 -N21:X1:1 /5.C3 -N20:X1:1 -U20:X 2:3 /5.B7 -U20:X2:4 /5.B7 -U20:X 2:2 /5.B7 -U21:X2:3 /6 .C7 -U21:X 2:4 /6[...]

  • Page 85

    RD 18 RD 18 RD 18 RD 18 RD 18 RD 18 BU 18 BU 18 BU 18 RD 18 BU 18 RD 18 GN 18 RD 18 BU 18 /6.A1 /3.F8 -X10 23 /3.D5 -X10:32 /6.A4 -X10: 34 -X10 33 GN 18 -U20 BURNER F AN (HOT AIR) X1: X2: X3: X1: X2: 1 1 23 1 2345 1 2345 6 7 89 1 0 1 1 1 2 3 2 1 -N20 BURNER CO NTROL (HOT AIR) -R20 1 2 101 -X10 RD 18 RD 18 BU 18 61 -X10 60 BU 18 HOT SURF ACE IGNITIO[...]

  • Page 86

    -X10 /4.E6 -X10 11 -X10: 33 RD 16 RD 16 HOT SURF ACE IGNITION (STEAM GE N) STEAM GENERAT OR BURNER CO NTROL BU 18 RD 18 BU 18 RD 18 -R21 2 1 FLAME SENSOR -P2 -N21 3 12 3 RD 18 2 X2: 45 X1: 67 1 89 1 0 -T2 /5.A8 22 OVER TEMPERATURE THERMOSTAT (STEAM GENERATOR ) OR 16 BU 16 BK 16 WH 16 24 VAC 120VAC BU 18 RD 18 /4.F7 /4.F7 /4.B3 /4.A4 BU 16 BU 16 -A2[...]

  • Page 87

    2 4 VAC 1 20V AC -T1 2 4 VAC TR AN SFOR M E R TR AN SFOR M E R 1 20V AC -T2 RE CI EV E TR AN S M I T 12V GN D -A20:X2 6 1 3 4 2 MO TO R DR IV E 2A RD -Z1 L1 N LINE FIL TER N L1 FA N GN D Rx D 12V CO M TxD V2 / W H W2 /Y E U2 /R D -U10 SH GN D M 3 ~ CONVEC TI O N V1 / B U U1 / B K W1 /B N -M1 -A10:X1 5 N L1 0 24 02 4 2 4 VAC 2 4 VAC 1 20 VAC M O TO [...]

  • Page 88

    HOT S URF A C E 1 2 -P 1 FL AM E SE NS OR -R20 1 2 S PEED S T E A M GE N E RAT O R GR OU ND STEA M G E N E R A T O R GA S BO AR D X2 : GR OUND HO T AIR 1 PO WE R BU RN ER HO T AI R FAN CONTR O L -U20 3 X1 : 54 12 CO NT RO L BO A R D -A10:X1 0 1 R ESE T 5 GN D 6 T x D _ 12V Rx D_ 12 V 0 V DC IN 2 X28 4 3 X3 : X3 : -U21 3 X2 : 3 1 21 3 54 2 1 X1 : 2 [...]

  • Page 89

    DOOR MAGNET S W I T C H 14 X14 : 2 1 7 5 6 4 3 10 8 9 PU MP / C L EAN A G E N T C O MPAR TMEN T R I NS E V . STEAM GEN OVER T E M P X15 : 1 2 3 4 BU W A TER L EVEL P R O B E H -B 1 L RD 5 7 86 9 10 11 12 13 -S 2 13 -S 7 14 14 13 6 GN /B U X16 : 1 DEHUMIDICATION / V A L V E GN /R D GN GN 4 5 GN 3 2 KTM CTC -B1 0 -B 6 -B 5 -B 3 RD WH YL 87 YL 9 10 RD[...]

  • Page 90

    CLEVELAND RANGE OGS 6.20/10.10 SEQUENCE OF OPERATIONS When using these instructions refer to the OGS 6.20/10.10 wiring schematic. 1 When 120 VAC is applied to the combi, it is sent through the line filter (Z1) to the Power Control Switch (S1). 2 When the Power Control Switch (S1) is closed a The red light in the switch is energized. b 120 VAC is se[...]

  • Page 91

    • When the heat circuit is energized the h eat symbol will be energized • The cooking mode symbol will be energized. • The time display will invert and begin to count down. b The fan circuit is energized by the Control Board (A10) transm itting and receiving a signal from terminals 5,6, and 7 on connector X10 to connector X12 on the Motor Dri[...]

  • Page 92

    a The front display will include a li ghted bar under the Hot Air sym bol • When the heat circuit is energized the h eat symbol will be energized • The cooking mode symbol will be energized. • The time display will invert and begin to count down. c The fan circuit is energized by the Control Board (A10) transm itting and receiving a signal fr[...]

  • Page 93

    e When the timer counts to 0 or the core tem p probe (B10) reaches the set amount the cycle . 5 With the combi in the Combi mode with tim e on the timer, the door closed and the start switch is depressed a The front display will include a li ghted bar under the Com bi symbol • When the heat circuit is energized the h eat symbol will be energized [...]

  • Page 94

    e When the condensate box is heated to 140 degrees F at the B3probe, 120 VAC is sent from terminal 5 of connector X 12 to the condenser valve (Y1) until the temperature drops. f If the “Crisp and Tasty” mode is selected • 120 VAC is sent from terminal 6 of connector X12 on the Control Board (A10) to the Dehumidification Valve (Y2) to pu ll th[...]

  • Page 95

    ◊ The Hot Air Burner Control Module (N20) senses at least 1.5 micro amps DC from the flame sensor (P1) at te rminal 3 of connector X2 and sends a signal from terminal 2 of connector X1 to term inal 12 of connector X15 on the Control Board (A10) • The heat circuit will remain energized until the cabin et set temperature is reached as sensed at p[...]

  • Page 96

    CLEVELAND RANGE, LLC 1333 East 179th S t., Cleveland, Ohio 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWING NO. THIS DES IGN DESCRIBES A PROPRIETAR Y ITEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DR AWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE. TITLE SIZE B WIRING DIAGRAM OGS 6.20/10 .10 3004[...]

  • Page 97

    -M1 M 3~ W2/YE U1/B K GND 20 -X10 POWER SUPPLY 12VDC 96-264V AC 12V DC 1 L1 GND FAN 2 3 N BK 12 BU 12 30 -X10 BK 12 -F1.1 2A 1 2 -X10 31 RD 18 L N RD 18 -A10:X12: 1 /3.D6 0V 12V BU 18 RD 18 RD 18 /3.D4 -A10:X10:4 /3.D4 -A10:X10 :3 /A6 -U10:X12: 1 BU 18 2 1 -F10 15A BK 18 GN 18 -U10 L2 L1 12V RxD TxD COM V U GND W P1 P2 /E3 -G1:12V RD 18 /3.B3 -A10:[...]

  • Page 98

    M SM 5010 -M3.1 -Y1 -F2.1 -A10 -X10 -X10 -S7 -S2 -X10 -Y10 -Y20 -Y22 -Y23 /2.E3 -G1:12V /2.E3 -G1: 0V /2.C4 -X10: 31 1 2 345 6 7891 0 1 1 1 2 1 2 3 4567 81 2 3 4 5 6 7 1 14 13 12 11 10 5 7 9 86 3 4 2 1 10 9 876 1 543 2 10 12 11 9 876 1 543 2 10 9 876 1 543 2 10 9 8 7 6 3 1 2 4 5 X14: X11: X15: X16: X10: X19: X17: X18: BU 18 BU 18 RD 18 RD 18 RD 18 [...]

  • Page 99

    RD 18 RD 18 RD 18 RD 18 RD 18 RD 18 BU 18 BU 18 BU 18 RD 18 BU 18 RD 18 GN 18 RD 18 BU 18 /3.F8 -X10 23 /3.D6 -A10:X11:8 -X10 33 GN 18 -U20 BURNER F AN (HOT AIR) X1: X2: X3: X1: X2: 1 1 23 1 2345 1 2345 6 7 89 1 0 1 1 1 2 3 2 1 -N20 BURNER CO NTROL (HOT AIR) -R20 1 2 101 -X10 RD 18 RD 18 BU 18 61 -X10 60 BU 18 HOT SURF ACE IGNITION (HOT AIR) -X10:4[...]

  • Page 100

    F E D C B A 12345678 F E D C B A 12345678 CLEVELAND RANGE, LLC 1333 East 179th S t., Cleveland, Ohio 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWING NO. THIS DES IGN DESCRIBES A PROPRIETAR Y ITEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DR AWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE. TITLE [...]

  • Page 101

    F E D C B A 12345678 F E D C B A 12345678 CLEVELAND RANGE, LLC 1333 East 179th S t., Cleveland, Ohio 44110-2574 VOLTAGE: WATTAGE: CURRENT: DATE SHEET OF REV DRAWN BY DRAWING NO. THIS DES IGN DESCRIBES A PROPRIETAR Y ITEM AND IS THE PROPERTY OF CLEVELAND RANGE. THIS DR AWING IS NOT TO BE COPIED OR USED WITHOUT THE APPROVAL OF CLEVELAND RANGE. TITLE [...]