Cooper Lighting ADH080747 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Cooper Lighting ADH080747, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cooper Lighting ADH080747 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Cooper Lighting ADH080747. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Cooper Lighting ADH080747 should contain:
- informations concerning technical data of Cooper Lighting ADH080747
- name of the manufacturer and a year of construction of the Cooper Lighting ADH080747 item
- rules of operation, control and maintenance of the Cooper Lighting ADH080747 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cooper Lighting ADH080747 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cooper Lighting ADH080747, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cooper Lighting service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cooper Lighting ADH080747.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Cooper Lighting ADH080747 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Automotive Dealership Design Guide[...]

  • Page 2

    AUTOMOTIVE DESIGN GUIDE TABLE OF CONTENTS Outdoor Site Lighting that heightens consumer awareness ...................3 - Feature Display Lighting ...................................................................7 - High Competition Displays ...............................................................8 - Medium Competition Displays ............[...]

  • Page 3

    SITE | SHOWROOM | SERVICE LEADING THE LIGHTING INDUSTRY Cooper Lighting is a recognized industry leader offering first-class lighting solutions for even the most challenging applications. Addressing every area of an automotive dealership, Cooper Lighting manufactures high performance products that create inviting areas of uniform illumination, endu[...]

  • Page 4

    3 4 OUTDOOR SITE LIGHTING CONSIDER YOUR LOCATION When selecting the proper light levels for your next dealership project, first determine how much visual competition is created by adjoining properties. The human eye is drawn to the brightest area in its field of view. In order to capture consumer attention, site lighting illuminance levels should b[...]

  • Page 5

    CONSIDER YOUR IMAGE Site lighting provides a means of navigation through the exterior merchandising area and rounds out the overall aesthetic appeal of the automotive dealership. Whether your style calls for the simple elegance of a square housing or the fluid appeal of a rounded architectural luminaire, Cooper Lighting is a recognized site lightin[...]

  • Page 6

    5 6 CONSIDER YOUR POCKETBOOK When selecting site lighting products, three important cost factors should be evaluated— fixture construction, energy consumption and maintenance cycle. Corrosive moisture, broad temperature variation and flocking insects make the outdoor environment particularly challenging for optimal luminaire performance. Premium [...]

  • Page 7

    Lamp Type Lamp Orientation Maintained Lumens Life [hrs.] Input Watts Efficacy [lms/w] 1000W Probe Start MH Vertical 82,000 10,000 1080 102 Horizontal 71,500 9,000 1080 97 1000W Pulse Start MH Vertical 96,000 15,000 1100 109 Horizontal 86,000 9,000 1100 98 875W Pulse Start MH Vertical 80,000 20,000 940 106 Horizontal 76,000 12,000 940 101 750W Pulse[...]

  • Page 8

    7 8 FEATURE DISPLAY LIGHTING FLEXIBILITY AND VERSATILITY The use of floodlighting products to highlight an automobile on an exterior display stand or platform is a powerful merchandisi ng technique. Directional sources play off the vehicle’s form to reveal its appeal, attracting attention and increasing the likelihood of con necting with the cust[...]

  • Page 9

    HIGH COMPETITION SITE LIGHTING High Horizontal Maintained Uniformity Area to Illuminate Levels [fc] [Max.Min.] Parking and Circulation [Non-Merchandising Area] 10 10:1 General Merchandise [Main Automotive Display Lot] 50 5:1 Featured Displays [Front Row and Display Stands] 75 3:1 1000W MH FLAT GLASS ENHANCED FRONT ROW DISPLAY Areas with extremely h[...]

  • Page 10

    9 10 ENHANCED 1000W MH FLAT GLASS ENERGY SAVING DIMMING After hours operation of money and energy saving Hi-Lo dimming relay mounted internal to the fixture. Mounting Height [ft.] 27.5 Spacing [ft.] 55 Maintained Average FC 32.1 Uniformity 1.15 POLE FIXTURE COMBINATION ORDERING LOGIC Distribution Fixture Configuration Product Family 1 80 MPH 90 MPH[...]

  • Page 11

    1000W MH FLAT GLASS GENERAL MERCHANDISE DISPLAY IESNA recommends 50 FC average illuminance for areas of high competition. Mounting Height [ft.] 27.5 Spacing [ft.] 60 Maintained Average FC 50.2 Uniformity 1.26 POLE FIXTURE COMBINATION ORDERING LOGIC Distribution Fixture Configuration Product Family 1 80 MPH 90 MPH 100 MPH Area Round [AR] 3 @ 90° Ta[...]

  • Page 12

    11 12 MEDIUM COMPETITION SITE LIGHTING 1000W MH FLAT GLASS FRONT ROW DISPLAY IESNA recommends 50 FC average illuminance for areas of medium competition. Mounting Height [ft.] 25 Spacing [ft.] 60 Maintained Average FC 61.9 Uniformity 2.45 POLE FIXTURE COMBINATION ORDERING LOGIC Distribution Fixture Configuration Product Family 1 80 MPH 90 MPH 100 MP[...]

  • Page 13

    1000W MH FLAT GLASS GENERAL MERCHANDISE DISPLAY IESNA recommends 30 FC average illuminance for areas of medium competition. Mounting Height [ft.] 27.5 Spacing [ft.] 62 Maintained Average FC 31.9 Uniformity 1.16 POLE FIXTURE COMBINATION ORDERING LOGIC Distribution Fixture Configuration Product Family 1 80 MPH 90 MPH 100 MPH 2 Area Round [AR] 2 @ 180[...]

  • Page 14

    13 14 LOW COMPETITION SITE LIGHTING 1000W MH FLAT GLASS FRONT ROW DISPLAY IESNA recommends 35 FC average illuminance for areas of medium competition. Mounting Height [ft.] 2 5 Spacing [ft.] 65 Maintained Average FC 52.5 Uniformity 2.89 POLE FIXTURE COMBINATION ORDERING LOGIC Distribution Fixture Configuration Product Family 1 80 MPH 90 MPH 100 MPH [...]

  • Page 15

    1000W MH FLAT GLASS GENERAL MERCHANDISE DISPLAY IESNA recommends 20 FC average illuminance for areas of medium competition. Mounting Height [ft.] 27.5 Spacing [ft.] 93 Maintained Average FC 21.9 Uniformity 1.88 POLE FIXTURE COMBINATION ORDERING LOGIC Distribution Fixture Configuration Product Family 1 80 MPH 90 MPH 100 MPH 2 Area Round [AR] 2 @ 180[...]

  • Page 16

    15 16 SHOWROOM LIGHTING NEO-RAY [Nimbus] AMBIENT METALUX [Ovation] TASK + AMBIENT LUMARK [Avid] TASK + AMBIENT RSA [Combolight] TASK + ACCENT INSPIRATION AND FUNCTIONALITY Showrooms are multifunctional facilities used for customer reception, retail display and business-closing transactions. Discret e tasks performed in each area require custom ligh[...]

  • Page 17

    SHOWROOM LIGHTING THAT ENHANCES MERCHANDISE APPEAL. PORTFOLIO [MD6] TASK + WALL WASH HALO [Stasis] ACCENT HALO [Connetix] ACCENT SURE-LITES [CCX] SAFETY INVITING Overall dealership ambiance plays a crucial role in evoking a sense of comfort and directly impacts the customer’s ability to make important decisions. A warm and inviting ambiance can b[...]

  • Page 18

    17 18 SERVICE DEPARTMENT LIGHTING PRODUCTIVITY LEADS TO PROFITABILITY The success of the service department is measured in productivity, and ultimately, profitability. Without proper lighting, the likelihood of costly mistakes and wasted time increases. The appropriate type and level of illumination greatly improves quality and workmanship in gener[...]

  • Page 19

    SERVICE DEPARTMENT LIGHTING THAT INCREASES PRODUCTIVITY. ENERGY SAVINGS Service department lighting offers a great opportunity to increase energy savings and improve overall profitability. Energy efficient building design practices outlined in the ASHRAE 90.1-2004 standard recommend a maximum power density of 0.7 W/ft 2 for automotive service depar[...]

  • Page 20

    Cooper Lighting Customer First Center 1121 Highway 74 South Peachtree City , GA 30269 P: 770-486-4800 F: 770-486-4801 www .cooperlighting.com International Sales, USA Cooper Lighting 1121 Highway 74 South Peachtree City , GA 30269 P: 770-486-4800 F: 770-486-4801 Canada Cooper Lighting 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-507-400[...]