Cooper Lighting Architectural Area Luminaire manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Cooper Lighting Architectural Area Luminaire, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cooper Lighting Architectural Area Luminaire one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Cooper Lighting Architectural Area Luminaire. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Cooper Lighting Architectural Area Luminaire should contain:
- informations concerning technical data of Cooper Lighting Architectural Area Luminaire
- name of the manufacturer and a year of construction of the Cooper Lighting Architectural Area Luminaire item
- rules of operation, control and maintenance of the Cooper Lighting Architectural Area Luminaire item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cooper Lighting Architectural Area Luminaire alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cooper Lighting Architectural Area Luminaire, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cooper Lighting service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cooper Lighting Architectural Area Luminaire.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Cooper Lighting Architectural Area Luminaire item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    T alon Ar chitectural Ar ea Luminair e[...]

  • Page 2

    TALON VERSATILE PERFORMANCE Talon’s ingenious blend of performance and versatility allows application specific illumination by way of fourteen [14] high efficiency, field rotatable optical systems. Offered with the unrivaled Spill Light Eliminator [SL] optic for areas requiring strict light trespass control, and the premier Automotive Front Row [[...]

  • Page 3

    SITE + PARKING | ROADWAY | PATH OF EGRESS IMPENETRABLE FORM Coupling precise mechanical design with premium quality materials, the Talon site light is constructed to sustain the rigors of outdoor operation. Thick wall die-cast aluminum construction and channel set silicone gasketing form an impenetrable IP65 barrier optimizing optical efficiency an[...]

  • Page 4

    3 4 PERFORMANCE + VERSATILITY MAXIMIZE SITE UNIFORMITY Add sparkle to your site and maximize pole spacings with sag glass optical systems offered in both cutoff and semi-cutoff configurations. For applications mandating full cutoff, choose from a complete offering of flat glass vertical lamp solutions. The vertically lamped family of optical system[...]

  • Page 5

    LEADING SPILL CONTROL The Spill Light Eliminator [SL] optic is the industry leader in effective spill light control, eliminating light beyond one [1] mounting height behind the pole with no sacrifice in forward illumination. Used along site perimeters and property lines, the Spill Light Eliminator keeps the light inside and the darkness out. ROTATI[...]

  • Page 6

    5 6 AUTOMOTIVE SOLUTIONS[...]

  • Page 7

    OUTDOOR SITE LIGHTING THAT ENGAGES CUSTOMER AWARENESS. Exterior site lighting provides the first impression of an automotive dealership and is an outward expression of image. During daytime hours the exterior site lighting fixture form should be selected to lend focus to dealership architecture and branding. For evening opera tion, properly illumin[...]

  • Page 8

    7 8 QUALITY + DURABILITY DURABLE CAST CONSTRUCTION Low-copper alloy die-cast aluminum construction offers corrosion resistance while precise tolerance control ensures tight nesting of the door and housing. Combining heat extracting reveal channels with independent optical and electrical chambers that isolate heat producing sources, the Talon’s ho[...]

  • Page 9

    CONFIDENCE-INSPIRING QUALITY BEYOND THE SUM OF ITS PARTS. From the stainless steel hinges to the rugged housing, every detail of the Talon construction is precisely designed with industry leading craftsmanship. Heavy-wall die-cast aluminum construction, premium TGIC [triglycidyl isocyanurate] polyester powder coat paint and an IP65 rate d optical c[...]

  • Page 10

    9 10 CONTROL + EFFICIENCY 0° [nadir] 180° UH Back Forward Uplight 30° 30° 60° 60° 80° 80° 90° 90° 100° 100° UL UL BVH FVH BH FH BM FM BL FL LUMINAIRE CLASSIFICATION The IESNA’s revised Luminaire Classification System [TM15-07 revised] creates a new basis of measurement for site lighting visibility and adjacent property interaction. Th[...]

  • Page 11

    STEPPING UP TO THE CHALLENGE. As visual research advances so too the core understanding of how light interacts with surrounding communities and nocturnal env ironments. Utilizing this knowledge, Federal programs, national organizations and industry leaders institute guidelines for illuminating an area safely and securely while reducing energy, elim[...]

  • Page 12

    [...]

  • Page 13

    [...]

  • Page 14

    13 14 MOUNTING Extruded 8" [TLM Talon Medium] or 10 1/2" [TLL Talon Large] aluminum arm includes internal bolt guides allowing for easy positioning of fixture during installation to pole or wall surface. Standard single carton packaging of housing, square pole arm and round pole adapter for contractor friendly arrival of product on site. [...]

  • Page 15

    FINISH Housing and arm finished in a 5 stage premium TGIC polyester powder coat paint, 2.5 mil nominal thickness for superior protection against fade and wear. Standard colors include black, bronze, grey, white, dark platinum, and graphite metallic. RAL and custom color matches available. Consult the McGraw-Edison Architectural Colors brochure for [...]

  • Page 16

    15 16 OPTIONS + ACCESSORIES ARM MOUNT Standard 8" [TLM] or 10 1/2" [TLL] extruded aluminum arm features internal bolt guides for twin support rods. Round pole mounting accommodated by utilizing provided round pole adapter between the fixture arm and pole shaft. EXTERNAL MAST ARM ADAPTER [MS] Cast aluminum mast arm adapter secures fixture [...]

  • Page 17

    OPTIONS [Factory installed and shipped complete with luminaire] Electrical F =Single Fuse [120, 277 or 347V] FF =Double Fuse [208, 240 or 480V] Q =Quartz Restrike EM =Quartz Restrike w/Delay [Also Strikes at Cold Start] EM/SC =Quartz Emergency Separate Circuit PT =Electrical Power Tray [Standard on TLL] P =Button Type Photocontrol [TLM Only] R =NEM[...]

  • Page 18

    17 18 STEEL POLES + BRACKETS ORDERING INFORMATION SAMPLE NUMBER: RSS4A20SFM2XG ISOTACH WIND MAP This map has been included to aid in pole selection with regard to geographic location. Although a less stringent 25-year mean recurrence map is sometimes used by other pole suppliers, it is our belief that the added measure of assurance offered with the[...]

  • Page 19

    FROM ANCHOR BOLTS TO LUMINAIRE AND EVERYTHING IN BETWEEN. Cooper Lighting offers a comprehensive line of steel and aluminum poles, brackets and mounting accessories to complete your sit e lighting application. Visit www.mcgraw-edison.com to view McGraw-Edison’s entire collection of mounting options. STEEL POLES [Specification Features] ROUND STRA[...]

  • Page 20

    19 20 ALUMINUM POLES + PHOTOMETRICS ALUMINUM POLES [Specification Features] ROUND STRAIGHT ALUMINUM [RSA] Fixture Mounting Drilled or Tenon [Must specify]. Shaft 6005-T6 aluminum alloy with polished finish. Handhole Flush reinforced 2 3/8" x 4 1/2" for 4" shafts. Handhole assembly with internal reinforcing frame. 3" X 5" fo[...]

  • Page 21

    PHOTOMETRICS [Complete IES files available at www.cooperlighting.com] FOOTCANDLE TABLE Select mounting height and read across for footcandle values of each isofootcandle line. Distance in units of mounting height. Mounting Footcandle Values for Height Isofootcandle Lines AB C D E 175W [3V/AS] 15' 1.70 0.85 0.34 0.17 -- 20' 1.00 0.50 0.20 [...]

  • Page 22

    21 22 TLM TALON MEDIUM ORDERING INFORMATION SAMPLE NUMBER: TLM-400-MH-MT-3F-FG-BK-HS VOLTAGE 5 120 =120V 208 =208V 240 =240V 277 =277V 347 =347V 480 =480V DT =Dual-Tap 6 MT =Multi-Tap 6 TT =Triple-Tap 6 5T =5-Tap 6, 7 DISTRIBUTION Horizontal Lamp 2F =Type II Formed 2S =Type II Segmented 3F =Type III Formed 3S =Type III Segmented 4F =Type IV Formed [...]

  • Page 23

    TLL TALON LARGE ORDERING INFORMATION SAMPLE NUMBER: TLL-1000-MH-5T-SL-FG-BK VOLTAGE 4 120 =120V 208 =208V 240 =240V 277 =277V 347 =347V 480 =480V DT =Dual-Tap 5 MT =Multi-Tap 5 TT =Triple-Tap 5 5T =5-Tap 5 DISTRIBUTION Horizontal Lamp 2F =Type II Formed 2S =Type II Segmented 3, 6 3F =Type III Formed 3S =Type III Segmented 3, 6 4F =Type IV Formed 4S[...]

  • Page 24

    Cooper Lighting Customer First Center 1121 Highway 74 South Peachtree City , GA 30269 P: 770-486-4800 F: 770-486-4801 www .cooperlighting.com International Sales, USA Cooper Lighting 1121 Highway 74 South Peachtree City , GA 30269 P: 770-486-4800 F: 770-486-4801 Canada Cooper Lighting 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-507-400[...]