A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Cornelius pmnice systems, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Cornelius pmnice systems one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Cornelius pmnice systems. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Cornelius pmnice systems should contain:
- informations concerning technical data of Cornelius pmnice systems
- name of the manufacturer and a year of construction of the Cornelius pmnice systems item
- rules of operation, control and maintenance of the Cornelius pmnice systems item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Cornelius pmnice systems alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Cornelius pmnice systems, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Cornelius service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Cornelius pmnice systems.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Cornelius pmnice systems item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    built for the long haul. ice systems[...]

  • Page 2

    Buying an ice machine is a decision you will live with for a long time. For the money, you want an ice machine that delivers more performance for less cost, over a longer period of time. You want Cornelius. Efficient Water/Electrical Compressors and condensers are matched precisely to provide the perfect balance between water and electrical use. Al[...]

  • Page 3

    *See warranty for details. TH E LONG HAUL. TH E LONG HAUL. Self-Insulated ABS Evaporator Housing Nickel-Plated Copper Evaporator Insulated, Double-W all Bulkhead In-Line W ater Pump Microban ® Antimicrobial Product Protection Programmable W ater Control Quick-Change Merchandising Panel Front-Mounted LED Future Proof R-404a Refrigerant Exclusive Ic[...]

  • Page 4

    PRODUCTION CHART AIR-COOLED W ater T emperature (˚F) Air T emp (˚F) 50 70 80 70 46 lbs. 41 lbs. 40 lbs. 80 44 lbs. 40 lbs. 40 lbs. 90 42 lbs. 38 lbs. 35 lbs. S eries 50† Series 200 SPECIFICA TIONS OPERA TING LIMITS Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient W ater W ater V oltage Number Condenser T ype Electrical Capa[...]

  • Page 5

    C U B E R S 5 Series 300"Xtreme" ARI CERTIFIED PERFORMANCE Ice Harvest Potable Water KWH Condenser Model Rate Use Consumption Water Use Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs. XAC322/XAC330 269 16.7 8.5 n/a XWC322/XWC330 269 16.7 6.8 149 DIMENSIONS/CAP A CITY PLUMBING Model Nominal Cabinet Water Electrical Service N[...]

  • Page 6

    Series 600"Xtreme" ARI CERTIFIED PERFORMANCE Ice Harvest Potable Water KWH Condenser Model Rate Use Consumption Water Use Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs. XAC630 547 16.3 6.9 n/a XWC630 589 17.4 5.6 116 XRC630 547 16.3 6.9 n/a SPECIFICA TIONS OPERA TING LIMITS Model Refrigerant Standard Circuit Maximum Shippi[...]

  • Page 7

    Series 800"Xtreme" ARI CERTIFIED PERFORMANCE Ice Harvest Potable W ater KWH Condenser Model Rate Use Consumption W ater Use Number lbs. per 24 hrs. per 100 lbs. per 100 lbs. per 100 lbs. XAC830 666 16.3 6.9 n/a XWC830 700 17.4 5.6 116 XRC830 666 16.3 6.9 n/a SPECIFICA TIONS OPERA TING LIMITS Model Refrigerant Standard Circuit Maximum Ship[...]

  • Page 8

    Series 1400"Xtreme" SPECIFICA TIONS OPERA TING LIMITS Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water Water V oltage Number Condenser T ype Electrical Capacity Fuse Size W eight Weight T emperature T emperature Pressure Range XAC1444 Air -Cooled R-404a 208/230/60/1 30 30 317 lbs. 274 lbs. 50°F-100°F 45°F-90?[...]

  • Page 9

    C U B E R S C H U N K L E T S 9 Series 2448 SPECIFICA TIONS OPERA TING LIMITS Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water W ater Voltage Number Condenser T ype Electrical Capacity Fuse Size Weight W eight T emperature T emperature Pressure Range IRC2448 AC Remote* R-404a 208-230/60/1 30 30 396 lbs. 335 lbs. 50°F-100[...]

  • Page 10

    C H U N K L E T S 10 Series 1000 DIMENSIONS/CAP A CITY PLUMBING Model Nominal Cabinet W ater Electrical Service Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening WCC-1001A 1015 lbs. 22"w x 24"d x 27"h SS 1 ⁄ 4 " male flare 3 ⁄ 8 " I.D. x 9 ⁄ 16 " O.D. 7 ⁄ 8 " diameter hole WCC-1001W 1015 l[...]

  • Page 11

    C H U N K L E T S F L A K E R S 11 Series 2000 DIMENSIONS/CAP A CITY PLUMBING Model Nominal Cabinet W ater Electrical Service Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening WCC-2001A 1999 lbs. 30"w x 24"d x 28"h SS 1 ⁄ 4 " male flare 3 ⁄ 8 " I.D. x 9 ⁄ 16 " O.D. 7 ⁄ 8 " diameter hole WC[...]

  • Page 12

    F L A K E R S 12 Series 725 SPECIFICA TIONS OPERA TING LIMITS Model Refrigerant Standard Circuit Maximum Shipping Operating Ambient Water W ater Voltage Number Condenser T ype Electrical Capacity Fuse Size Weight Weight T emperature T emperature Pressure Range AF725PSCR Air-Cooled R-404a 115/60/1 20 20 334 lbs. 300 lbs. 50°F-100°F 50°F-90°F 20-[...]

  • Page 13

    F L A K E R S D I S P E N S E R S 13 Series 2000 DIMENSIONS/CAP A CITY PLUMBING Model Nominal Cabinet W ater Electrical Service Number Capacity Dimensions Finish Inlets/Outlets Drainhose Opening WCF-2201A 2506 lbs. 30"w x 24"d x 28"h SS 1 ⁄ 4 " male flare 3 ⁄ 8 " I.D. x 9 ⁄ 16 " O.D. 7 ⁄ 8 " diameter hole [...]

  • Page 14

    D I S P E N S E R S A C C E S S O R I E S 14 Remote Condensers •W eatherproof housing •H igh-efficiency copper and aluminum condenser •R educes air conditioning requirements Cabinet Finish: Galvanized Cornelius Bagger •T ime-saving • No mess • Less melting • Convenient • Innovative design Dimensions: 22"w x 10 1 ⁄ 4 "d x[...]

  • Page 15

    B I N S 15 • Wide Selection… T welve models ranging from 120 to 1315 lbs. storage capacity . • Corrosion Proof… All Cornelius storage bins constructed of rotomolded polyethylene or 304 grade stainless steel are virtually corrosion proof. Our standard baked enamel finished bins will provide years of corrosion resistant service. • Easy Main[...]

  • Page 16

    S P E C I F I C A T I O N G U I D E 16 LOCATION Always locate the ice machine where ambient temperatures will not fall below 50˚F nor rise above 100˚F . CLEARANCE Always make certain the machine and storage bin will fit through all doors and hallways leading to the final installation site. When installed, there must be a 6-inch air clearance on r[...]

  • Page 17

    S P E C I F I C A T I O N G U I D E 17 The quick reference sizing guide works well in many cases; however , more and more customers’ ice needs are changing. T oday’ s customers use ice for numerous applications such as product cooling, self-serve beverages, product packaging, display and, in some cases, retail package sales. T o meet customer n[...]

  • Page 18

    S P E C I F I C A T I O N G U I D E 18 The previous sizing methods assume that the icemaker will run continuously 24 hours a day . This total utilization of the icemaker gives the customer the most cost effective way of producing the required ice. It also requires the bin to be properly sized or the cus- tomer will run out of ice. The example below[...]

  • Page 19

    S P E C I F I C A T I O N G U I D E 19 A GENERAL REVIEW OF THE RULES FOR SIZING ICEMAKERS AND BINS 1. Ice needs are seldom uniform; more ice is generally needed in summer than in winter . Understanding the ice usage of the customer is a must to assure sufficient ice is available to meet peak demands. Remember , water temperature, as well as the sur[...]

  • Page 20

    CA TG 8699 © 2002 IMI Cornelius www .cornelius.com[...]