Crestron electronic 2-Series Control Processor manual
- Read online or download the manual
- 40 pages
- 1.23 mb
Go to page of
Similar user manuals
-
Computer Hardware
Crestron electronic CP2
40 pages 1.23 mb -
Computer Hardware
Crestron electronic CP2E
40 pages 1.23 mb -
Computer Hardware
Crestron electronic 2-Series Control Processor
40 pages 1.23 mb -
Computer Hardware
Crestron electronic Crestron DualTouchTM Technology Touchpanel
28 pages 3.46 mb -
Computer Hardware
Crestron electronic UPX-OS4GB-MSO-2007
8 pages 0.25 mb -
Computer Hardware
Crestron electronic DTT-15V3
28 pages 3.46 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Crestron electronic 2-Series Control Processor, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Crestron electronic 2-Series Control Processor one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Crestron electronic 2-Series Control Processor. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Crestron electronic 2-Series Control Processor should contain:
- informations concerning technical data of Crestron electronic 2-Series Control Processor
- name of the manufacturer and a year of construction of the Crestron electronic 2-Series Control Processor item
- rules of operation, control and maintenance of the Crestron electronic 2-Series Control Processor item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Crestron electronic 2-Series Control Processor alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Crestron electronic 2-Series Control Processor, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Crestron electronic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Crestron electronic 2-Series Control Processor.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Crestron electronic 2-Series Control Processor item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
[...]
-
Page 2
This document was prepared and written by th e Technical Docum entation department at: Crestron Electronics, Inc. 15 Volvo D rive Rockleigh, NJ 076 47 1-888-CRESTRON[...]
-
Page 3
Crestron CP2/CP2E 2-Series Integrated Control Processor Contents 2-Series Integrated Control Processor: CP2/CP2E 1 Introduc tion ................................................................................................................... ............ 1 Features and Functions ...................................................................[...]
-
Page 4
[...]
-
Page 5
Crestron CP2/CP2E 2-Series Integrated Control Processor 2-Series Integrated Control Processor: CP2/CP2E Introduction Features and Functions Crestron’s CP2 and CP2E 2-Series Integrated Con trol Processors, cost-competitive options in Crestron's 2-Series line of in te grated c ontrol system s, are designed for smaller home and comm ercial netw[...]
-
Page 6
2-Series Integrated Control Processor Crestron CP2/CP2E bit Motorola ColdFire processor. The 2-Series operating system is vastly upgraded from Crest ron’s X-gene ration pro ducts, yet compatible with existing Crestron software and programm ing. A key feat ure is the new Crestro n Compil er, which allows any existing Cres tron SIMPL™ W indow[...]
-
Page 7
Crestron CP2/CP2E 2-Series Integrated Control Processor Physical Description The CP2/CP2E integrated control systems are housed in black enclos ures with labeling on t he front an d rear panels . The front panels of b oth units i nclude standar d LEDs and two reset buttons. All conn ections to the units are made through th eir rear panels. The fr o[...]
-
Page 8
2-Series Integrated Control Processor Crestron CP2/CP2E Controls and Indicators The CP2/CP2E front panel indicators a nd controls a re described bel ow. PWR (Power) This LED illuminates when the unit is co nnected to and receives 24VDC power from an AC power pack or the C resnet NET connector. NET This LED illuminates when the central processing un[...]
-
Page 9
Crestron CP2/CP2E 2-Series Integrated Control Processor NOTE: The orientation of this connector is “upside down” co mpared to other Crestron networ k devices (e.g., CNX-BI PAD8, CNX-RMCLV). Be sure the mating Cresnet cable connector is pr operly aligned before attempting to insert it, to avoid damage to the CP2/C P2E unit . This connect or (typ[...]
-
Page 10
2-Series Integrated Control Processor Crestron CP2/CP2E COM Pinout to RS-485 Bus COM ( DB9) CO NNECT O R RS-485 BUS T ie Pins 1 & 9 - T ie Pins 4 & 6 + Pin 5 G INFRARED – SERIAL OU TPUT A B C D E F G H S G S G S G S G INFRA RED - SERIAL OUTPUT S G S G S G S G These connectors provi de eight serial outp uts for IR or serial int erface. Eac[...]
-
Page 11
Crestron CP2/CP2E 2-Series Integrated Control Processor 24VDC, 2.0A (Power Supply) 24VDC 2.0A This male connector can be used to supply 24 VDC power to the CP2/CP2E from an AC power pac k purchased se parately. (Re fer to O ptional Powe r Supply on page 1 3). When power is supplied to th e units through this connector, 24VDC, 24W is also available [...]
-
Page 12
2-Series Integrated Control Processor Crestron CP2/CP2E series control engine. Non-vo latile memory c ontains information that is retained after loss of electrical power. Volatile memory is lost after a power failure. Refer to the lists below for a breakdown of memory usage for program-related information stored in the unit. Flash The 4MB flas h me[...]
-
Page 13
Crestron CP2/CP2E 2-Series Integrated Control Processor DRAM DRAM is use d by the ope rating system for dynam ic storage of variables, si gnals and other const ructs use d at runti me. The actua l amount of DR AM used at a ny given time depends on the particular program that is running , i.e., usage is variable, or dynamic, du ring norm al operat i[...]
-
Page 14
2-Series Integrated Control Processor Crestron CP2/CP2E Ear Attachment for Rack Mounting (CP2E shown in illustration) 1. Using a Phillips screwdriver, remove and retain the three side screws closest to the fr ont panel. 2. Position a rack ear so that its mounting holes align with the vacated holes, and secure the ear to t he unit with the three sc [...]
-
Page 15
Crestron CP2/CP2E 2-Series Integrated Control Processor 5. Secure the wires connected to the te rm inal block with a ti e wrap around the bussing stri p to provi de strain reli ef. Network Wiring NOTE: When making wire connections, refer to the latest revision of the Cresnet Network Inte rconnect Dra wing (Doc. 5411 ). The document can be obtai ned[...]
-
Page 16
2-Series Integrated Control Processor Crestron CP2/CP2E Wire Gauge Values RESISTANCE (R) WIRE GAUGE 4 16 6 18 10 20 15 22 13 Doubled CAT 5 8.7 Tripled CAT5 NOTE: When dais y-chaining Cresnet unit s, stri p the ends of the wires carefully to avoid nicking the condu ctors. Twist together the ends of the wires that share a pi n on the network conn ect[...]
-
Page 17
Crestron CP2/CP2E 2-Series Integrated Control Processor Optional Power Supply The units ca n be powe red through t he NET netw ork conne ctor, or by an optional AC power p ack (pur chased separa tely). If an ex ternal power supply is to be used , Crestron reco mmends it s CNPWS-75 E xternal Po wer Supply or PW-24 20RU Universal Power Pack, or e qui[...]
-
Page 18
2-Series Integrated Control Processor Crestron CP2/CP2E Slot 1: C2Net-Device The C2Net-De vice slot ena bles the CP2 an d CP2E to c ontrol up t o 252 Cr esnet devices. Each Cresnet de vice is assigned a unique identifier called a Net ID, which is a hexadecim al value rangi ng from 03 to FE. To view the list of supported devices, ex pand the control[...]
-
Page 19
Crestron CP2/CP2E 2-Series Integrated Control Processor Slot 3: C2I-IO8 The CP2 and C P2E pro vide eight I/O ports c alled Ve rsiports, eac h of whi ch can function as a digital i nput, a di gital out put, or an a nalog in put. Each Versi port has a correspondin g pullup resistor. In Program Manager, d rag the C2I-I O8 sym bol from Progr am View to[...]
-
Page 20
2-Series Integrated Control Processor Crestron CP2/CP2E Driving the correspondi ng <pu-disabl e> signal hi gh can modi fy this beha vior. This i s not recommended, though , since it will cause the output pin to float when < o > goes low. Example 1 (rec ommended): The < pu-disable1 > signal is driven low or left undefined. When <[...]
-
Page 21
Crestron CP2/CP2E 2-Series Integrated Control Processor A voltage source is pl aced on Ve rsiport 1 a nd < MinChange1 > is set t o 10 via an Analog Initialize symbol. The value of < i1 > will not be propag ated until it changes by at least 10. If the current value is 500, then a new value will not be reported until it chang es to 510 or[...]
-
Page 22
2-Series Integrated Control Processor Crestron CP2/CP2E 3. When all t he IP IDs and ass ociated IP ad dresses have been adde d to the IP Table, click Send IP Table to Contr ol System . As with all 2-Series control systems, the CP2E has the capability to fun ction as a peripheral d evice, or “sla ve”, in a m aster/slave arra ngement with another[...]
-
Page 23
Crestron CP2/CP2E 2-Series Integrated Control Processor If the program contains S IMPL+ or User modules , the conversion might generate error messages. This is because m odules and programs often c ontain symbols with “ambiguous” s ignals. F or exam pl e, the inputs of the Serial to Analog sym bol can be defined as eith er analog or serial. Alt[...]
-
Page 24
2-Series Integrated Control Processor Crestron CP2/CP2E Module Header Information After you convert each module in a prog ram, you can convert the program as described pre viously: dra g the CP2 or CP2E ont o the exis ting cont rol syst em in System Views and click Yes to confirm the re placement. For further i nformat ion about com pile-tim e erro[...]
-
Page 25
Crestron CP2/CP2E 2-Series Integrated Control Processor • Hardware ha ndshaking (R TS/CTS) e nabled. • Software ha ndshaki ng (XON/ XOFF) not e nabled. “Port Settings” dialog box: Default PC se ttings for RS-232 co mmunication with the CP2/CP2E. To verify com muni cation, click Diagnostics | Establish Communications (Find Rack) . T his shou[...]
-
Page 26
2-Series Integrated Control Processor Crestron CP2/CP2E use a CAT5 cr ossover cabl e to connect th e two LAN ports directly, without using a hub. Once the cable connections are made, ope n the Crest ron Viewpo rt and clic k Setup | Communication Settings on the m enu to di splay the “Po rt Settings” di alog bo x. Then click TCP/I P as the conn [...]
-
Page 27
Crestron CP2/CP2E 2-Series Integrated Control Processor some ma y be internal (e. g., for a m odem). Cons ult the m anufacture r’s documentation for fur ther information about th e COM ports on your PC. 3. Check the ERR LED indicat or on the f ront panel of the CP 2/CP2E. If this LED is illuminated, unplug the unit and reapply power after a few s[...]
-
Page 28
2-Series Integrated Control Processor Crestron CP2/CP2E Compiling and Uploading a Program to the Control System After you have completed your SI MPL Windows program you must compile and upload the program to the control system. To compile the program, simply click the Convert/Compile button on the SIMPL Windo ws toolbar, o r select Project | Conver[...]
-
Page 29
Crestron CP2/CP2E 2-Series Integrated Control Processor Another way to verify t hat the program has been tra nsferred successfully is to select Report Program Information on the View port Functions menu. Prog ram information is also disp layed in the View port console whenever power is removed and re-applied to the CP2/CP2E. Uploading Web pages to [...]
-
Page 30
2-Series Integrated Control Processor Crestron CP2/CP2E Uploading Touchpanel Pr ojects via the CP2/CP2E You can use a connection t o the CP2 or CP2E to upload Visi onTools Pro- e projects to any Cresnet touchpa nel. Com piled projects f or TPS pane ls are contai ned in V TZ files; project s for all othe r touchpa nels are cont ained in HEX files. B[...]
-
Page 31
Crestron CP2/CP2E 2-Series Integrated Control Processor 3. After the transfer is complete, the CP2/CP2E will automatically reboot. To confirm the tr ansfer , click Diagnostics | Check Ops Version . The Viewport c onsole sho uld disp lay the new .c uz versi on num ber. Advanced Console Commands The SIMPL Wi ndows onli ne help fil e provides a full l[...]
-
Page 32
2-Series Integrated Control Processor Crestron CP2/CP2E Troubleshooting The table belo w and on t he next page provides cor rective action fo r possible trouble situations. If further assistance is requi red, please contact a Crestron cust omer service representative. CP2/CP2E Troubleshooting TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Unexpected r[...]
-
Page 33
Crestron CP2/CP2E 2-Series Integrated Control Processor Battery Replacement A Lithium battery is used to power the system clock within the CP2/CP2E. Under normal conditions, it will last for approximately 10 years. In the event that the clock fails, only an authorized technician sh ould replace it. Refer to caution statem ent below. CAUTION: Dange [...]
-
Page 34
2-Series Integrated Control Processor Crestron CP2/CP2E Passthrough Mode Dialog Box The PC will now be communicating directly with th e device. To exit Passthr ough mode, simply cl ick Functions | Exit Passthr ough Mode . A system reboot will also exit Passthrough mode. 30 • 2-Series Integrated Cont rol Processor: CP2/CP2E Operations Guide - DOC.[...]
-
Page 35
Crestron CP2/CP2E 2-Series Integrated Control Processor Further Inquiries If after reviewing this Operations Guide, you cannot locate specific information or have questions , please take a dvantage of Crestron's award winning c ustomer servi ce team by calling: • In the US and Canada, call C restr on's corpo rate headquarte rs at 1-888-[...]
-
Page 36
2-Series Integrated Control Processor Crestron CP2/CP2E Software License Agreement This License Agreement (“Agree ment”) is a legal contract betw een you (either an individual or a single business entit y) and Crestron Electronics, Inc. (“Crestron”) for so ftware referenced in this guide, which in cludes co mputer softwa re and, as applica [...]
-
Page 37
Crestron CP2/CP2E 2-Series Integrated Control Processor If You are a business or organization, You agree that upon request from Crestron or its authorized agent, You will within thirty (30) days fully document and certify that use of any and all Software at the time of the request is in conformity with Your valid licenses from Cres tron of its auth[...]
-
Page 38
2-Series Integrated Control Processor Crestron CP2/CP2E Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchan dise may be retur ned for cr edit, exchan ge, or service without prior authorization from CR ESTRON. To obt ain warrant y service f or CRESTR ON products, cont act the fact ory and req uest an RMA (R eturn Me rchan[...]
-
Page 39
Crestron CP2/CP2E 2-Series Integrated Control Processor This page intentionally left blank . Operations Guide - DOC. 5980 2-Series Integrated Control Processo r: CP2/CP2E • 35[...]
-
Page 40
Crestron Electronics, Inc. Operations Guide – DOC. 5980 15 Volvo Drive Rockleigh, NJ 07647 02.02 Tel: 888.CRESTRON Fax: 201.767.7576 Specifications subject to www.crestron.com change without notice.[...]