A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of CyberPower OL8000E, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of CyberPower OL8000E one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of CyberPower OL8000E. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of CyberPower OL8000E should contain:
- informations concerning technical data of CyberPower OL8000E
- name of the manufacturer and a year of construction of the CyberPower OL8000E item
- rules of operation, control and maintenance of the CyberPower OL8000E item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of CyberPower OL8000E alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of CyberPower OL8000E, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the CyberPower service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of CyberPower OL8000E.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the CyberPower OL8000E item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
User ’ s Manual OL6000ERT3UD OL8000ERT3UD OL10000ERT3UD CyberPower Systems Inc. www .cpsww .com K01 ‐ 0000220 ‐ 00 [...]
-
Page 2
Copyright © 201 1 CyberPower Systems, Inc. IMPORT ANT SAFETY INSTRUCTIONS 1 This manual cont ains important ins tructions. Ple ase read and fol low all instructi ons carefully d uring installation and operation of the unit. Re ad this manu al thoroughly before attempting to un pack, install, or o perate the UPS. CAUTION! Th[...]
-
Page 3
Copyright © 201 1 CyberPower Systems, Inc. UNP ACKING Power module Input / Output terminal block cover 2 U s e r ’ s m a n u a l R e g i s t e r c a r d Rackmount left rail * 2 sets Rackmount right rail * 2 sets Phone line USB communication cable Serial Interface Cable (RS-232) Battery module Rackmount ears (Stands) (2) * 2 sets [...]
-
Page 4
Copyright © 201 1 CyberPower Systems, Inc. HARDW ARE INST ALLA TION HARDW ARE INST ALLA TION These versatile UPS systems can be mo unted in a r ackmount or vertical tower orientation. This versatility is es pecially important to gr owing organizations wit h changing needs that value having t he option to position a UPS on a floor o[...]
-
Page 5
Copyright © 201 1 CyberPower Systems, Inc. HARDW ARE INST ALLA TION VERTICAL/T OWER INST ALLA TION Step 1: Rotate the Multifunctio n LCD Module Unscrew the right pan el of the Power modu le. Separate the righ t panel from the UPS. Gently lift t he LCD module out. Rotate i t to the tower orientation. Reins tall it for a tower config[...]
-
Page 6
Copyright © 201 1 CyberPower Systems, Inc. INST ALLING YOUR UPS SYSTEM SYSTEM BLOCK DIAGRAM HARDW ARE INST ALLA TION GUIDE 1. Battery charge loss may occur durin g shipping and s torage. Before using the UPS, it’s strongly recommen ded to charge batteries for f our hours to ensur e the batteries ’ maxi mum charg[...]
-
Page 7
Copyright © 201 1 CyberPower Systems, Inc. HARDWIRING THE INPUT/ OUTPUT TERMINALS CHECK CIRCUIT BREA KER/WIRING Check branch circuit breaker rating and w iring dimensi ons with the follow ing table. UPS Capacity Branch Circuit Breake r Wiring A WG Wiring mm 2 6KV A 40A 10 A WG 5.5 mm 2 8KV A 50A 8 A WG 8.0 mm 2 10KV A 60A 6 A WG 14[...]
-
Page 8
Copyright © 201 1 CyberPower Systems, Inc. HARDWIRING THE INPUT/ OUTPUT TERMINALS Step 1: Separate the top and botto m covers Loosen the four s crews to separate t he top and botto m covers. 7 Step 2: Fix the bottom co ver on the terminal bloc k Tighten the two screws to fix t he bottom cover on t he terminal bloc k. Step 3: Bypass con[...]
-
Page 9
Copyright © 201 1 CyberPower Systems, Inc. HARDWIRING THE INPUT/ OUTPUT TERMINALS Connect the three wires to the input t erminal block. Step 5: Output configuration Insert the output c able through t he appropriate c able gland (not included) 8 Connect the three wires to the output terminal block. Step 6: Fix th[...]
-
Page 10
Copyright © 201 1 CyberPower Systems, Inc. BACKFEED PROTECTION BACKFEED PROTECTION OPERA TION 1. If the Bypass circ uit is shorted and th e UPS is running in Line Mode or Battery Mo de, backfeed protec tion will be ac tive and th e e xternal isolation d evice (Magnetic Contact or) will open. 2. Save your data and per form a control[...]
-
Page 11
Copyright © 201 1 CyberPower Systems, Inc. BASIC OPERA TION POWER MODULE FRON T/REAR P ANEL DESCRIP TION 10 1. Power Button / Power on Indicator Master ON/OFF for the UPS. Indicates that th e UPS is on and supplying power . 2. UPS Status / Fault / Replace Battery LED Indicator Indicates the status of the UPS whether is operati [...]
-
Page 12
Copyright © 201 1 CyberPower Systems, Inc. BASIC OPERA TION BA TTER Y MODULE FRONT/RE AR P ANEL DESCRI PTION 1. On-board Replaceable Fuse Cover Replaceable fuse is accessible from t he rear panel. It m ust be done by qualifi ed personnel. 2. AC Circuit Breaker Provides overload and fault prot ection. 3. AC Output Outlet Use this ou[...]
-
Page 13
Copyright © 201 1 CyberPower Systems, Inc. BASIC OPERA TION CONNECTION #2 : PO WER MODULE WITH MUL TIPLE BA TTERY MODULES Step 1: Connect the 1 st Battery module to the Power module using the instructions above. Step 2: Loosen the two screws to remove the battery cable retention bracket of the 1 st battery module. Step 3: Use the o[...]
-
Page 14
Copyright © 201 1 CyberPower Systems, Inc. OPERA TION INSTRUCTIONS FOR LCD MODULE LED INDICA TORS – UPS ST A TUS LED Indicators Color UPS Status Description ON/OFF Blue UPS power is on. ON-LINE Green UPS is operating in Line Mode. BA TTER Y ON Ye l l o w UPS is operati ng in Battery Mode. BYP ASS Ye l l o w UPS is operati[...]
-
Page 15
Copyright © 201 1 CyberPower Systems, Inc. LCD SETUP FUNCTIONS 14 MUL TI-FUNCTION LCD MAIN MENU Press “ Enter ” button to activate “ MAIN MENU ”. MAIN MENU submenu Function Description Information Displays the UPS information. Configure Displays the UPS settings that can be config ured by the user . Event Log Displays the 3 mos[...]
-
Page 16
Copyright © 201 1 CyberPower Systems, Inc. LCD SETUP FUNCTIONS 15 LCD EVENT LOG 3 Event Logs of UPS can be recorded. 1. Press the “ ENTER ” button to activate the “ MAIN MENU ”. 2. Press the “ ▲ ” and “ ▼ ” buttons to scroll to the “ E vent Log ” option. 3. Press the “ ENTER ” button to select the “ Ev[...]
-
Page 17
Copyright © 201 1 CyberPower Systems, Inc. LCD SETUP FUNCTIONS 16 Configure Submenu A vailable Settings Default Setting Output V oltage = [200V] [208V] [220V] [230V] [240V] 230V* Sync Freq Wi ndow Range= [+/- 1%] [+/- 2%] [+/- 3%] [+/- 4%] [+/- 5%] [+/- 6%] [+/- 7%] [+/- 8%] [+/- 9%] [+/-10%] +/- 5% Bypass V Windo w Range= [+10%/-10%] [...]
-
Page 18
RE M Step Unsc r from t Step Conn Por t SA F CAU T CAU T LC D M OTE CON T 1: Remove the M r ew the right pa n t he UPS. Gently 2: Connect the ect the DB26 c a t ” on the front pa n F ETY PREC A T ION! It must b T ION! To a v o i d D MODUL E T ROL M ultifunction L C n el of the Powe r lift the LCD mod u DB26 Cable a ble from LCD m n el[...]
-
Page 19
Copyright © 201 1 CyberPower Systems, Inc. MAINTENANCE Storage T o store y our UPS for an extended period, c over it and store with the battery fully charg ed. Recharge the battery every thr ee months to ens ure battery life. Battery Replacement Please read and follow the Safet y Instructions bef ore servicing the battery . Batt er[...]
-
Page 20
Copyright © 201 1 CyberPower Systems, Inc. TECHNICAL SPECIFICA TIONS Model OL6000ERT3UD OL8000ERT3UD OL10000ERT3UD Configuration Capacity (V A) 6000V A 8000V A 10000V A Capacity (W atts) 5400W 7200W 9000W Form Factor Rackmount / T ower Energy-saving T echnology Y es, ECO Mode Efficiency > 95% Input Input V oltage Ran ge 120~139V ac [...]
-
Page 21
Copyright © 201 1 CyberPower Systems, Inc. TROUBLE SHOOTING Problem Possible Cause Solution Warning O/P Overload Y our equipment requires mo re power than the UPS can provide. If the UPS is in Line Mode then it will transfer to Bypass Mode; if the UPS is in Battery Mode it will shutdown. Shut off non-essential equipment. If this solves[...]