A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Datacom Systems VS series SPAN, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Datacom Systems VS series SPAN one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Datacom Systems VS series SPAN. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Datacom Systems VS series SPAN should contain:
- informations concerning technical data of Datacom Systems VS series SPAN
- name of the manufacturer and a year of construction of the Datacom Systems VS series SPAN item
- rules of operation, control and maintenance of the Datacom Systems VS series SPAN item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Datacom Systems VS series SPAN alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Datacom Systems VS series SPAN, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Datacom Systems service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Datacom Systems VS series SPAN.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Datacom Systems VS series SPAN item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Datacom Systems Inc © 2004-2007 by Datacom Systems Inc. All Rights Reserved. June 2007 541-0106-U-A.01 SP AN and Multi-link Aggr egators/Regenerators USER guide SS series SP AN Aggr egators/Regenerators VS series SP AN Aggr egators/Regenerators VS series Multi-link Aggr egators/Regenerators SS series SP AN VS series SP AN VS series Multi-Link[...]

  • Page 2

    [...]

  • Page 3

    Datacom Systems Inc Copyright Copyright © 2004-2006 by Datacom Systems, Inc. All rights reserved. Printed in the United States of America. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written[...]

  • Page 4

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 4 Compliance T esting CA UTION: Changes or modifications to this unit not expressly approved by the party responsible for com- pliance could void the user ’ s authority to operate the equipment. Certifications This equipment has been tested and found to meet the rad[...]

  • Page 5

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 5 Content s What Shipped? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Attributes &[...]

  • Page 6

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 6 What Shipped ? SS series SP AN Aggregators/Regenerators 1 — SS-(200, 201, 202 or 203) 2 — Switching AC Adapters 2 — AC Power Cords 1 — Warranty Card 1 — QUICK install Guide 1 — USER guide VS series SP AN Aggregators/Regenerators 1 — VS-(1022BT -BT , 10[...]

  • Page 7

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 7 Introduction The SP AN and Multi-link Aggregator/Regenerators can combine data from multiple Ethernet network segments into one stream of data. A single device, such as an intrusion detection system, protocol analyzer , or network probe can receive the aggregated da[...]

  • Page 8

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 8 SINGLEstream ™ SS-200 Series Overview — Datacom Systems' SINGLE str eam ™ series SP AN Aggregator/Regenerator provides a superior solution for 24x7 monitoring of full-duplex Ethernet links. While traditional Ethernet taps might enable full-duplex monitori[...]

  • Page 9

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 9 The SINGLE str eam ™ series SP AN Aggregator/Regenerator faultlessly combines the two data streams, allowing any connected monitoring device to receive a full-duplex stream of data with one NIC. Additionally , the SINGLE str eam ™ series SP AN Aggregator/Regener[...]

  • Page 10

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 10 SS-200 Specifications Specification Channel T wo SP AN Feature Cable T ype CA T 5E P or t Connectivity: NETWORK A NETWORK B T AP 1 A/B T AP 2 A/B RJ45 RJ45 RJ45 RJ45 Distance Limit 100 meter maximum length between network end-points. T ap , typically 1 meter . P ow[...]

  • Page 11

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 11 SS-200 Hardware Description — Figure 1 illustrates the SS-200 series SP AN Aggregator/Regenerator front panel. This is the location for all cable connections and status LEDs. Figure 1 - SS-200 Fr ont Panel and functional diagram An explanation of each front panel[...]

  • Page 12

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 12 SS-200 Application & Hardware Inst allation — The SS-200 is used primarily in conjuction with two SS-100s to monitor and anlay- sis Primary and Redundant Distribution Networks. Figure 2 depicts a typical set of monitoring tools attached to a primary circuit t[...]

  • Page 13

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 13 S tep 3. Connect the other primary network cables to the primary SINGLE str eam ™ S-100 RJ45 port NETWORK B connector . The NETWORK-B LINK LED illuminates indicating link has been established between the NETWORK B connector and primary NETWORK B device. !!!: The [...]

  • Page 14

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 14 VERSAstream ™ SP AN Series Overview — The VERSA str eam ™ SP AN aggregator/regenerator provides a single turnkey solution for 24x7 monitoring of redundant, failover , two-link EtherChannel and asymmetric net- work segments. It provides the ability to monitor [...]

  • Page 15

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 15 VERSAstream ™ SP AN Series Features & Benefit s • Connect any compatible device (protocol analyzer , probe, intrusion detection system, more) for simultaneous monitoring of two full-duplex SP AN Ports - eliminates the need for network connectors to be disco[...]

  • Page 16

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 16 VERSAstream ™ SP AN Series Specifications VERSA stream ™ VS-1062BT VS-1031BT VS-1031BT -02 VS-1022BT -BT TCP Reset 2(10/100/1000) 2(10/100/1000) NO 2(10/100/1000) 6(10/100/1000) NO 1(10/100/1000) 3(10/100/1000) NO 1(10/100/1000) 3(10/100/1000) YES NETWORK POR T[...]

  • Page 17

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 17 VERSAstream ™ SP AN Hardware Description — Figure 3 through Figure 12 illustrates the VERSA str eam ™ SP AN Series aggregator/regenerator front panel. This is the location for all cable connections and status LEDs. Figure 3 - VS-1022BT -BT Fr ont Panel and fu[...]

  • Page 18

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 18 Figure 6 - VS-1041LX-LX Front Panel and functional diagram Figure 7- VS-1041SX-SX Front Panel and functional diagram Figure 8 - VS-1062BT Fr ont Panel and functional diagram[...]

  • Page 19

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 19 Figure 9 - VS-1082 Front Panel and functional diagram Figure 10 - VS-1082LX-BT Fr ont Panel and functional diagram Figure 1 1 - VS-1082SX-BT Fr ont Panel and functional diagram[...]

  • Page 20

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 20 An explanation of each front panel legend follows: PO WER: T wo power supplies are provided for each module. Use of the second power supply is strongly recommended to assure uninterrupted monitoring. Furthermore, connecting the second power supply to a different ex[...]

  • Page 21

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 21 MONITOR: These ports are either RJ45 or duplex-LC connectors used for connection to NIC MONITOR card connectors of each network monitoring tool. network con- nections. The LED Display Code T able deciphers the RJ45 jacks with inte- grated LEDs that display line sta[...]

  • Page 22

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 22 2. Connect network cables to the VERSA str eam ™ NETWORK duplex-LC ports. The LED associated with each duplex-LC jack is solid green indicating when light signal has been detected on the respective Rx NETWORK port. 3. Connect analysis devices to the VERSA str eam[...]

  • Page 23

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 23 Figure 15 - VS-1022BT -BT Hardwar e Installation Primary/Redundant Router Application — shown in Figure 15 , focuses on monitoring and analyzis of the SP AN output of a Primary and Redundant network aggregated into one single stream of data. This VS-1022SX-SX is [...]

  • Page 24

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 24 T o connect the VERSAstream ™ VS-1022BT -BT SP AN Series aggregator/regenerator , refer to Figure 15 and follow these steps: 1. T wo power supplies are provided. Use of the second power supply is strongly recommended to assure uninterrupted monitoring. Connect bo[...]

  • Page 25

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 25 VERSAstream ™ Multi-link Series Overview — The VERSA str eam ™ Multi-Link Aggregator can combine data from multiple Ethernet network segments into one stream of data. A single Gigabit device, such as an intru- sion detection system, protocol analyzer , or net[...]

  • Page 26

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 26 Features and Benefit s • Connect any Gigabit (Gbps) device (protocol analyzers, probes, intrusion detection system, more) for permanent simultaneous monitoring of multiple full-duplex links — eliminates the need for network connectors to be disconnected and con[...]

  • Page 27

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 27 Dimensions — VS-1026BT -BT , VS-1028, VS-1028SX, VS-1046, VS-1046SX, VS-1412, or VS-1610: VS1412 kit or VS1610 kit: 1.125" (H) x 8.750" (W) x 7.500" (D) (includes rack mount chassis br ack et) 30 mm (H) x 225 mm (W) x 190 mm (D) 1.75" (H) x 19[...]

  • Page 28

    28 Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide VERSAstream ™ Multi-link Hardware Description — Figure 16 through Figure 22 illustrates the VERSA str eam ™ Multi-link Series aggregator/regenerator front panel. This is the location for all cable connections and status LEDs. Figure 16 - VS-1026BT -BT Fr ont [...]

  • Page 29

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 29 Figure 19 - VS-1046 Front Panel and functional diagram Figure 20 - VS-1046SX Front Panel and functional diagram Figure 21 - VS-1412 Front Panel (1 of 2 in kit) and functional diagram[...]

  • Page 30

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 30 Figure 22 - VS-1610 Front Panel (1 of 2 in kit) and functional diagram An explanation of each front panel legend follows: PO WER 1, 2: T wo power supplies are provided for each module. Use of the second power supply is strongly recommended to assure uninterrupted m[...]

  • Page 31

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 31 D AISY : D AISY ports IN and OUT are RJ45 connectors cabled to the next aggregator . The LED Display Code T able deciphers the RJ45 jacks with integrated LEDs that display line status and line speed of each port. Analyzing/Monitoring Gigabit EtherChannel CONCERN : [...]

  • Page 32

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 32 Unlike other solutions, the VERSA str eam ™ Multi-Link Aggregator when deployed with SINGLE str eam ™ Gigabit Aggregation T aps or other Datacom Systems Gigabit Ethernet taps provides complete visibility into Gigabit EtherChannel, while allowing network profess[...]

  • Page 33

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 33 T o connect the VERSAstream ™ VS-1028 Multi-link Series aggregator/regenerator , refer to Figure 23 and follow these steps: 1. T wo power supplies are provided. Use of the second power supply is strongly recommended to assure uninterrupted monitoring. Connect bot[...]

  • Page 34

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 34 VS-1028 with T aps Application — shown in Figur e 24 , focuses on a typical VERSA str eam ™ VS-1028 Multi-Link Aggregator application deployed with Datacom T aps to combine traffic from dif ferent network segments and output the aggregated data to either a sing[...]

  • Page 35

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 35 1,000 Mbs 100 Mbs 10 Mbs Green Orange OFF LED Display Code Link Data Code Lef t LED Solid Green Flashing Green Code WITH LINK OR DA T A Right LED T o connect the VERSAstream ™ VS-1028 Multi-link Series aggregator/regenerator , refer to Figure 24 and follow these [...]

  • Page 36

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 36 VS-1028 SP AN and In-line Application — shown in Figur e 25 , focuses on a typical VERSA str eam ™ VS-1028 Multi-Link Aggregator deployed to gain complete visibility into your SP AN and In-Line environments combining traffic from up to 8 dif ferent segments and[...]

  • Page 37

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 37 T o connect the VERSAstream ™ VS-1028 Multi-link Series aggregator/regenerator , refer to Figure 25 and follow these steps: 1. T wo power supplies are provided. Use of the second power supply is strongly recommended to assure uninterrupted monitoring. Connect bot[...]

  • Page 38

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 38 VS-1610 kit Application — shown in Figure 26 , focuses on a typical VERSA str eam ™ VS1610 kit (T wo VS-1610s mounted in RMC-2 Rack Mount Chassis and daisy-chained together) Multi-Link Aggregator deployed. This VS-1610 kit is similiar to the VS-1412 kit VERSA s[...]

  • Page 39

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 39 T o connect the VERSAstream ™ VS1610 kit Multi-link Series aggregator/regenerator , refer to Figure 26 and follow these steps: 1. T wo power supplies are provided. Use of the second power supply is strongly recommended to assure uninterrupted monitoring. Connect [...]

  • Page 40

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 40[...]

  • Page 41

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide 41 Customer Service This USER guide was written to help you get to know your new SINGLEstream ™ Link Aggregation T aps quickly and easily . W e would welcome any comments or suggestions you may have regarding this USER guide . Please send your remarks and recommenda[...]

  • Page 42

    Datacom Systems Inc SP AN and Multi-Link Aggr egators/Regenerators • USER guide[...]