A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Datalogic Scanning CBX500, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Datalogic Scanning CBX500 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Datalogic Scanning CBX500. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Datalogic Scanning CBX500 should contain:
- informations concerning technical data of Datalogic Scanning CBX500
- name of the manufacturer and a year of construction of the Datalogic Scanning CBX500 item
- rules of operation, control and maintenance of the Datalogic Scanning CBX500 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Datalogic Scanning CBX500 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Datalogic Scanning CBX500, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Datalogic Scanning service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Datalogic Scanning CBX500.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Datalogic Scanning CBX500 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
CBX500 INSTALLATION MANUAL Figure A Indicator LEDs 1 Cove r Screw s (4) 2 Compression Connectors ( 5) 4 25-pin Device Connect or 5 Fieldbus Interf ace Panel 3 5 1 2 4 3[...]
-
Page 2
CBX500 INSTALLATION MANUAL 2 Figure B Power switc h (ON/OFF) 1 2 Device Chassis Grounding Selector 3 Mounting Holes (2) 5 4 I/O Extension Module Connector Backup Module Connector 6 Indicator LEDs RS485 Termination Resistance Switch 7 ID-NET™ Termination Resistance Switch 8 Auxiliary Por t Connector 9 IP65 Fieldbus Module Connector 10 Standard Fie[...]
-
Page 3
CBX500 INSTALLATION MANUAL 3 UPDATES AND LANGUAGE AVAILABILITY UK/US The latest drivers and documentatio n updates for this product are availabl e on Internet. Log on to: www.automation.datalogic.com I Su Internet sono disponibili le versio ni aggiornate di driver e documentazione di questo pr odotto. Questo manuale è disponibile anche nell a vers[...]
-
Page 4
CBX500 INSTALLATION MANUAL 4 DESCRIPTION The CBX500 is a conn ection box which can be used a s an accessory to facilitate system connections for installation and device replac ement of several Datalogic family reading dev ices. System cabling is made throug h spring clamp terminal blocks i nside the CBX500 while the reading dev ice is connected to [...]
-
Page 5
CBX500 INSTALLATION MANUAL 5 SUPPORTED READING DEVICE MODELS The CBX500 can be directly connected to the following re ade rs through the 25-pin connecto r illustrated in Fi gure A. Linear Scanners 2D Readers DS2100N DS2400N DS4800 DS6300 MAT RIX -10 00 M ATRIX-2000 DS6400 DX6400 DS8100A DX8200A MATRIX 400 NOTE CBX500 is backward compatible with DS4[...]
-
Page 6
CBX500 INSTALLATION MANUAL 6 MECHANICAL INSTALLATION CBX500 can be mounted to various wooden o r plastic surfac es using the tw o self-threading screw s (3.9 x 45 mm) and washers p rovided in the package. Mounting to other surfaces such as concrete walls or metallic panels requires user-supplied parts (scre ws, screw anchors, nuts, etc). A mounting[...]
-
Page 7
CBX500 INSTALLATION MANUAL 7 through the utility program (s ee the reading device Insta llation Manual for more details). T he reading device auxiliary interfa ce signals are also availabl e on the internal spring clamp c onnectors. After making system cabling and s witch settings, connect the reading device to the 25-pin connector on the CBX500 ho[...]
-
Page 8
CBX500 INSTALLATION MANUAL 8 SYSTEM WIRING The connection and wiring procedure for CBX500 is descri bed as follows: 1) Open the CBX500 by unscrewing the four cover scre ws. 2) Verify that the CBX500 power switch is off (see Figure 3). 3) Unscrew the compression connectors and pass all the s ystem cables through them into the CBX500 h ousing. 4) To [...]
-
Page 9
CBX500 INSTALLATION MANUAL 9 PINOUT Pinouts Group Name Function Vdc Power S upply Input Voltage + GN D Power Suppl y Input Volta ge - Input Power Eart h Protection Earth Ground +V Power Source – Ex ternal Trigge r I1A External Trigger A (pola rity insensitive) I1B External Trigger B (pola rity insensitive) External Trigger Input -V Power Referenc[...]
-
Page 10
CBX500 INSTALLATION MANUAL 10 POWER SOURCE JUMPER SETTINGS For most applications input power is provided through t he dedic ated spring clamp connectors inside the CBX500. However CB X500 may acc ept power fro m the connect ed reading device thro ugh the 25- pin connector. T his is useful, for example, to pass po wer to connected acce ssories such [...]
-
Page 11
CBX500 INSTALLATION MANUAL 11 9-PIN READING DEVICE AUXIL IARY SERIAL INTERFACE The reading device au xiliary serial interface availab le on the internal CBX500 9- pin connector can be used eithe r for configuration or for data monitoring. Connections can be made to a PC or Lapt op using a straight through cable or a USB-RS232 conv erter. The detail[...]
-
Page 12
CBX500 INSTALLATION MANUAL 12 RS485 HD ON OFF Figure 11 – RS485 HD Terminati on Resistance Sw itch The RS485 HD termination r esistance switch enables or d is ables the inse rtion of the bus termination resistor for RS485 Half Duplex Multidrop applicati ons. CAUTION In Multiplexer applications the termination resi stor must be e nabled ONLY on th[...]
-
Page 13
CBX500 INSTALLATION MANUAL 13 TECHNICAL FEATURES ELECTRICAL FEATURES Supply Voltage 10 to 30 Vdc* Consumption 0.8 – 0.5 A Limited Current Consumption CBX + reading device cons umption (see related manual) 2.5 A USER INTERFACE LED In dic at ors Power On/Polarity Error (blue/r ed) Trigger (y ellow) IN2 (green) OUT1 (yellow) OUT2 (green) PHYSICAL FE[...]
-
Page 14
CBX500 INSTALLATION MANUAL 14 FCC COMPLIANCE Modifications or changes to this equipm ent without the expressed written approval of Datal ogic could void the authority to use the equipm ent. This device complies with PA RT 15 of the FCC Rules. Operation is subject to the following t wo conditions: (1) This device may not cause harmful in terfe rence[...]
-
Page 15
DECLARATION OF CONFORMITY 08 Datalogic A utomation S.r.l. Via S. Vitalino 13 40012 - Lippo di Calderara Bologna - Italy dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el CBX500 connection box modul ar; e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono c[...]