Datalogic Scanning DS4600A-XXX0 manual

1
2
3
4
5
6
7
8
9
10
11
12

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Datalogic Scanning DS4600A-XXX0, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Datalogic Scanning DS4600A-XXX0 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Datalogic Scanning DS4600A-XXX0. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Datalogic Scanning DS4600A-XXX0 should contain:
- informations concerning technical data of Datalogic Scanning DS4600A-XXX0
- name of the manufacturer and a year of construction of the Datalogic Scanning DS4600A-XXX0 item
- rules of operation, control and maintenance of the Datalogic Scanning DS4600A-XXX0 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Datalogic Scanning DS4600A-XXX0 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Datalogic Scanning DS4600A-XXX0, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Datalogic Scanning service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Datalogic Scanning DS4600A-XXX0.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Datalogic Scanning DS4600A-XXX0 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DS4600A QUICK GUIDE General View: Laser Safety: The scanner is classifi ed as a Class 2 las er product according to EN 60825-1 regul ations and as a Class II laser prod uct according to CDRH regulations. For installation, use an d maintenance it is not necessary to open the device. There is a safet y device which allo ws the laser to be switched on[...]

  • Page 2

    DS4600A QUICK GUIDE 2 Model Description: DS4600 A - X X X X Decoding Mode 2 = Standard w/ Display 3 = Ad vance d Code Re const ruct ion Reading Range 0 = Medium Range 1 = Long Range 2 = Sh ort Rang e Optic V ersion 0 = Linear 1 = Raster R1 2 = Raster R2 Special Features 0 = Standard 5 = Integrated Heater The following table displa ys each version?[...]

  • Page 3

    DS4600A QUICK GUIDE 3 Accessories: Name Description Part Number C-BOX 100/200 Con nection Box 93ACC1510, 93ACC152 0 C-BOX 300/310 Con nection Box Profibus 93A3 01000, 93A301030 C-BOX 400/410 Con nection Box DeviceNet 93A301010, 93A301040 GFC-41 90° Reading Device 91D081000 OM4000 Oscillating Mirror 93A251030 INT-30 (for C-Box 100) 20 mA Current Lo[...]

  • Page 4

    DS4600A QUICK GUIDE 4 Mechanical Installation: 10 0.39 41.8 1.64 M4 N° 4 37 1.47 5 0.2 11.8 0.46 81 3.19 8.25 0.32 87.9 3.46 M4 N°2 58 2.28 32.5 1.28 3.75 0.15 42 1.65 20 0.79 83.5 3.29 101 3.98 18 0.70 0.90 23 DS4600 A 37 20.2 1.46 22* 0.86 0.8 14.8 0.58 39.4 1.55 * The quote refers to the scan line Mounting hole depth M4 X 5 Overall dimensions [...]

  • Page 5

    DS4600A QUICK GUIDE 5 Connectivity: Point-to-point lay out c Main Serial Interface d Auxiliary Serial Interface (Local Echo) (RS232) e External Trigger (for On-Line Mode) Pass-through layout Multiplexer layout c Main Serial Interface (RS232) c Main Serial Interface (RS485 Half-Duplex) d Auxiliary Serial Interface (RS232) d Auxiliary Ser ial Interfa[...]

  • Page 6

    DS4600A QUICK GUIDE 6 Reading Diagrams: DS4600A -210X (Long Range) CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 Pitch angle = 0° Skew angle = 15° Tilt angle = 0° *Code Resolution: Standard - for 0.50 mm (20 mils) codes and greater *Code Reading Condition: Standard * Parameter selectable in WinHost. 4 -4 12 -12 -16 (in) 04 2 0 12 (in) [...]

  • Page 7

    DS4600A QUICK GUIDE 7 DS4600A-22XX (Short Ran ge) CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 "Pitch" angle = 0 ° "Skew" angle = 10 ° "Tilt" angle = 0 ° *SW Resolution = High * Parameter selectable in WinHost 2 1 0 -1 5 4 3 -2 -3 -4 -5 (in) 01 3 21 0 6 (in) 45 7 8 9 0 20 40 60 80 100 120 140 160 180 200 [...]

  • Page 8

    DS4600A QUICK GUIDE 8 DS4600A-2X1X (Raster R1) CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90 "Pitch" angle = 0° "Skew" angle = 18° "Tilt" angle = 0° *Code Resolution: High - for 0.30 mm (12 mils) codes and smaller Standard - for 0.50 mm (20 mils) codes and greater *Code Reading Condition: Standard * Parame[...]

  • Page 9

    DS4600A QUICK GUIDE 9 DS4600A-31XX (Long Ra nge) CONDITIONS Code = Interleaved 2/5 and Code 39 "Pitch" angle = 0 ° "Skew" angle = 15 ° "Tilt" angle = 0 ° *Code Resolution = Standard for 0.50 mm (20 mils) codes and greater *Code Reading Conditions = Standard * Parameter selectable in WinHost 4 -4 12 -12 -16 (in) 04 2[...]

  • Page 10

    DS4600A QUICK GUIDE 10 DS4600A-32XX (Short Range) CONDITIONS Code = Interleaved 2/5 and Code 39 PCS = 0.90 "Pitch" angle = 0° "Skew" angle = 15° "Tilt" angle = 0° *SW Resolution: High * Parameter selectable in WinHost. 4 2 0 -2 10 8 6 -4 -6 -8 -10 (in) 02 6 4 20 12 (in) 8 10 14 16 18 0 40 80 1 20 160 200 240 280 320[...]

  • Page 11

    DS4600A QUICK GUIDE 11 User Interface: RS232 PC-side connection s 1 5 9 6 9-pin male connector 13 25 14 1 25-pin male connect or Pin Name Pin Name 2 RX 3 RX 3 TX 2 TX 5 GND 7 GND 7 RTS 4 RTS 8 CTS 5 CTS How To Build A Simple Interface Test Cable: The following wirin g diagram shows a s imple test cable including power, external (pus h-button) trigg[...]

  • Page 12

    DATALOGIC S.p.A ., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy 05 dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el DS4600A-XXXX Laser Scanner e tutti i suoi modelli and all its models et tous ses modèles und seine modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo [...]