Datel DMS-PS-CM manual

1
2
3
4
5
6
7
8

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Datel DMS-PS-CM, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Datel DMS-PS-CM one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Datel DMS-PS-CM. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Datel DMS-PS-CM should contain:
- informations concerning technical data of Datel DMS-PS-CM
- name of the manufacturer and a year of construction of the Datel DMS-PS-CM item
- rules of operation, control and maintenance of the Datel DMS-PS-CM item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Datel DMS-PS-CM alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Datel DMS-PS-CM, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Datel service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Datel DMS-PS-CM.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Datel DMS-PS-CM item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    C ® US E156931 85-264V ac or 110-340Vdc Universal Input Mur ata P ow er So lut ion ’ s DM S-PS-C M S eries of high-efficiency , chassis mount A C/DC po we r s upp lie s f eatu re lo w nois e ( 40m V o n main, 8mV on auxiliaries), fully-isolated +24, +12V , and +5V outputs , making them perfect f or powering toda y’s comple x instrumenta - tio[...]

  • Page 2

    T echnical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 www .murata-ps .com P erformance/Functional Specifications T ypical at T A = +25°C and V IN = 85-264V @47-63Hz ➀ All models will also operate from a regula ted and filtered 110 to 340Vdc input. ➁ Unless otherwise specified, load regulation is measured with the output unde[...]

  • Page 3

    T echnical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 www .murata-ps .com TECHNICAL NO TES Ordering Information and Selection Guide MPS Part No. Rated P ower Efficiency ➀ V1 Output V2 Output V3 Output DMS-PS1-CM 5 W atts 75% 5Vdc/1A — — DMS-PS2-CM 5 W atts 73% 5Vdc/0.65A 4.85Vdc/0.2A — DMS-PS3-CM 5 W atts 71% 5Vdc/0.35A 4.8[...]

  • Page 4

    T echnical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 www .murata-ps .com The ac-mains circuit supplying power to DMS-PS-CM supplies must be fused according to the current rating of the wire gauge used, in accordance with applicable regulatory codes. The b uilt-in 1ampere line fuse (F1) only protects the module itself from destructi[...]

  • Page 5

    T echnical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 www .murata-ps .com 3. Model Selection & Energy Conservation: In order to achie ve the lowest possible energy consumption, be sure to determine your application’ s total current requirements. This is especially tr ue when using DMS-PS-CM supplies to power D A TEL ’ s ener[...]

  • Page 6

    T echnical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 www .murata-ps .com DMS-PS3-CM V1 (+5V) T ypical P erformance Curves T A = +25°C , V IN = 120V @60Hz Noise and Ripple - 100% Load, 20MHz Bandwidth DMS-PS6-CM V1 (+24V) DMS-PS9-CM V1 (+24V) DMS-PS3-CM V2 (+4.85V) DMS-PS6-CM V2 (+4.85V) DMS-PS9-CM V2 (+4.85V) DMS-PS-CM Series High[...]

  • Page 7

    T echnical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 www .murata-ps .com Mechanical Dimensions: Inches (mm) T olerances: 2 PL DEC ±0.02 (±0.51), 3 PL DEC ±0.010 (±0.254) T ransient Response - 10% to 100% Load Step DMS-PS3-CM V2 (+4.85V) DMS-PS6-CM V2 (+4.85V) DMS-PS9-CM V2 (+4.85V) DMS-PS3-CM V1 (+5V) DMS-PS6-CM V1 (+24V) DMS-P[...]

  • Page 8

    T echnical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000 www .murata-ps .com 0.188 (4.8) 0.125 (3.2) 5W models: 0.77 (19.6) 10W models: 0.87 (22.1) 16W models: 0.93 (23.6) 4.625 (117.5) 1.000 (25.4) 5.125 (130.2) TB4 TB1 TB2 TB3 AC(L) AC(N) FG + V1 – + V2 – + V3 – ® ® ® ® DMS-PSX-CM AC/DC PO WER SUPPL Y 2.835 (72.0) 1.42 (36.[...]