Go to page of
Similar user manuals
-
Electric Heater
Dayton 2E511B
16 pages 0.89 mb -
Electric Heater
Dayton 3.00E+132
24 pages 3.55 mb -
Electric Heater
Dayton 1RVT8
24 pages 2.52 mb -
Electric Heater
Dayton 3VH34
24 pages 3.55 mb -
Electric Heater
Dayton 3E219C
24 pages 0.67 mb -
Electric Heater
Dayton 3VH37
24 pages 3.55 mb -
Electric Heater
Dayton 3VH19
12 pages 0.39 mb -
Electric Heater
Dayton 3E218B
16 pages 0.89 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Dayton 3VG81, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dayton 3VG81 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Dayton 3VG81. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Dayton 3VG81 should contain:
- informations concerning technical data of Dayton 3VG81
- name of the manufacturer and a year of construction of the Dayton 3VG81 item
- rules of operation, control and maintenance of the Dayton 3VG81 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dayton 3VG81 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dayton 3VG81, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dayton service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dayton 3VG81.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Dayton 3VG81 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Operating Instructions & Parts Manual 3VG81 Dayton Pr opane Construction Heater ® Form 5S3928 Please read and save these instructions. Read car efully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failur e to comply with instructions could res[...]
-
Page 2
Dayton Operating Instructions and Parts Manual 3VG81 2 Dayton Pr opane Construction Heater ® General Safety Information IMPORT ANT : Make certain you r ead and understand all warnings. Keep these instructions for refer ence. They are your guide to safe and proper operation of this heater . Safety information appears throughout these instructions. [...]
-
Page 3
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 3 Model 3VG81 Carbon monoxide poisoning: Some people are mor e affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be operating prope[...]
-
Page 4
Dayton Operating Instructions and Parts Manual 3VG81 4 Dayton Pr opane Construction Heater ® Air For Combustion And Heating Fuel Combustion Chamber DSI Ignitor Clean Heated Air Out (Front) Fan Solenoid V alve Nozzle Motor On/Off Switch Theory of Operation THE FUEL SYSTEM The hose/regulator assembly attaches to the propane gas supply . The propane [...]
-
Page 5
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 5 Model 3VG81 Installation (Continued) Hose Propane T ank Hose POL Fitting Supply V alve Inlet Connector Regulator Vent (pointing down) Figure 4 - Regulator With V ent Pointing Down IMPORT ANT : Extra hose or piping may be used if needed. Install extra hose or piping[...]
-
Page 6
Dayton Operating Instructions and Parts Manual 3VG81 6 Dayton Pr opane Construction Heater ® Operation (Continued) Storage Disconnect heater from pr opane supply tank(s). 1. Store propane tank(s) in safe manner . See Chapter 5 of Standard for Storage and Handling of Liquefied Petroleum Gases, ANSI/NFP A 58. Follow all local codes. 2. Place plastic[...]
-
Page 7
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 7 Model 3VG81 IGNITOR Make sure gap between ignitor electr ode and burner nozzle is .13 min./.15"max. Access ignitor electrode fr om inside combustion chamber . No other mainte- nance is needed for ignitor . Wiring Diagrams Figure 9 - Electrical Ladder Diagram F[...]
-
Page 8
Dayton Operating Instructions and Parts Manual 3VG81 8 Dayton Pr opane Construction Heater ® Figure 9 - Repair Par ts Illustration For Repair Parts, call 1-800-323-0620 24 hours a day — 365 days a year 3VG81 33 2 1 31 12 26 43 32 10 11 38 20 21 6 7 6 5 3 37 34 Note: Screws are standard hardware items 28 7 15 46 27 8 14 36 29 39 4 8 13 25 23 17 4[...]
-
Page 9
Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 9 Model 3VG81 Repair Parts List 1 Upper Shell 098511-116 1 2 * #10-16 x 1/2" Screw M15823-27 8 3 Combustion Chamber Kit 098512-35 1 4 Nozzle 099138-01 1 5 Ignitor 099133-01 1 6 * #8-18 x 3/8" Screw M11084-38 2 7 Fuel T ube Kit 099334-01 1 8 Ignitor Cable 09[...]
-
Page 10
Dayton Operating Instructions and Parts Manual 3VG81 10 Dayton Pr opane Construction Heater ® 41 * #10-32 x 1/4" Screw M12461-25 2 42 * Hex TPG “F” 6-32 s 1/4" Screw M10908-1 2 43 Clip Nut M11271-8 8 44 High T emperature Wire Assembly 101480-10 1 45 High T emperature Wire Assembly 101480-11 1 47 DSI Control No. 2003-19 M51605-02 1 47[...]