Go to page of
Similar user manuals
-
Air Compressor
dbx Pro 1046
2 pages 0.32 mb -
Music Mixer
dbx Pro 223xs
2 pages 1.54 mb -
Satellite TV System
dbx Pro dB12
2 pages 0.64 mb -
Stereo Equalizer
dbx Pro 131
2 pages 0.1 mb -
Stroller
dbx Pro 1074
2 pages 0.09 mb -
Printer Accessories
dbx Pro AUTOVELOCITY DYNAMICS AND THE DBX 160SL
8 pages 0.13 mb -
Stereo Equalizer
dbx Pro iEQ-31
16 pages 1.21 mb -
Musical Instrument
dbx Pro 4800
96 pages 4.64 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of dbx Pro 386, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of dbx Pro 386 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of dbx Pro 386. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of dbx Pro 386 should contain:
- informations concerning technical data of dbx Pro 386
- name of the manufacturer and a year of construction of the dbx Pro 386 item
- rules of operation, control and maintenance of the dbx Pro 386 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of dbx Pro 386 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of dbx Pro 386, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the dbx Pro service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of dbx Pro 386.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the dbx Pro 386 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
® 386 Dual V acuum T ube Preamp w/Digital Out User Manual[...]
-
Page 2
W ARNING FOR Y OUR PRO TECTION PLEASE READ THE FOLLOWING: KEEP THESE INSTRUCTIONS HEED ALL WARNINGS FOLLOW ALL INSTRUCTIONS CLEAN ONL Y WITH A DAMP CLO TH. DO NOT BLOCK ANY OF THE VENTILA TION OPENINGS. INST ALL IN ACCORD ANCE WITH THE MANUF ACTURERS INSTRUCTIONS. DO NOT INST ALL NEAR ANY HEA T SOURCES SUCH AS RADIA TORS, HEA T REGISTERS, STOVES; O[...]
-
Page 3
U.K. MAINS PLUG W ARNING A molded mains plug that has been cut off from the cord is unsafe. Discard the mains plug at a suitable disposal facility . NEVER UNDER ANY CIRCUMST ANCES SHOULD YOU INSERT A D AMAGED OR CUT MAINS PLUG INTO A 13 AMP POWER SOCKET . Do not use the mains plug without the fuse cover in place. Replacement fuse covers can be obta[...]
-
Page 4
T able of Contents 386 Intr oduction 0.1 Defining the 386................................................i 0.2 Service Contact Info .........................................ii 0.3 W arranty ............................................................ii 0.4 Installation Recommendations........................iii Section 1 - Getting Started 1.1 Rear [...]
-
Page 5
INTRO CUSTOMER SER VICE INFO 386 DEFINED W ARRANTY INFO ® INTRODUCTION 386[...]
-
Page 6
Intr oduction ® 386 User Manual i 386 Congratulations on your pur chase of the dbx 386 Dual V acuum Tube Preamp with digital out - put capabilities. For over 25 years, dbx has been the industry leader in dynamics processing. With the intr oduction of the 386, we offer the classic smooth and warmth qualities of tube microphone pre-amplification, co[...]
-
Page 7
® Intr oduction 386 386 User Manual If you r equire technical support, contact dbx Customer Service. Be prepared to accurately describe the problem. Know the serial number of your unit - this is printed on a sticker attached to the rear panel. If you have not already taken the time to fill out your warranty r egistration card and send it in, pleas[...]
-
Page 8
Intr oduction ® 386 User Manual iii 386 Install the 386 in your rack with the provided rack scr ews. I t is essential that when the 386 is being mounted in a rack mounting enclosure, the unit should be positioned with enough ro om (at least one centimeter at the top and one centimeter at the bottom of the unit) to allow prop - er ventilation. The [...]
-
Page 9
Getting Started ® Getting Started Section 1 386[...]
-
Page 10
Getting Star ted ® 386 User Manual 2 Section 1 386 Power Switch Tu rns the 386 on and off . IEC Power Cord Receptacle This is the power cord receptacle of the 386. An IEC cord is included with the shipped prod - uct. AES/EBU Digital Connector The 386 provides AES/EBU digital output formating through the XLR connector . Be sure to use short lengths[...]
-
Page 11
® Instrument Input This unbalanced high-impedance input connection is used to insert an instrument signal direct- ly into the preamp. Use the LINE switch to make instrument input or the rear panel line input active. Plugging into the instrument jack will override the rear panel 1/4” input jack (line input must be selected). Line Select Switch Th[...]
-
Page 12
Getting Star ted ® 386 User Manual 4 Section 1 386 Meter Select Switch This switch allows you to select display metering of either the digital or analog output signal. The analog level is scaled in dBu, while the digital level is scaled in dBFS. LightPipe™ Meter This meter displays either the analog or digital output signal. Digital Output This [...]
-
Page 13
ANALOG APPLICA TIONS ® ANALOG APPLICA TIONS Section 2 386[...]
-
Page 14
Analog Applications ® 3 386 User Manual 6 Section 2 386 • Turn of f all equipment before making any connections. • Install the 386 in your rack with the provided rack scr ews. It i s essential that when the 386 is being mounted in a rack mounting enclosure, the unit should be positioned with enough room (at least one centimeter at the top and [...]
-
Page 15
® 1). Make microphone connections, being careful to keep the DRIVE control in the minimum (+30 dB) position. 2). Connect the 386’s Line outputs directly to the audio inputs of your r ecorder . 3). Enable the r ecord function of the specific track of the r ecorder and open the specific tape track return in the console which corresponds to the tra[...]
-
Page 16
[...]
-
Page 17
DIGIT AL APPLICA TIONS ® DIGIT AL APPLICA TIONS Section 3 386[...]
-
Page 18
Digital Applications ® 10 Section 3 386 Dither Switch This switch is used to select the dither type algorithms including: TPDF , SNR 2 , or None. Dither is random noise that is added to the audio signal which effectively eliminates the harmonic distor- tion created by truncation. See the“T runcation” graph in section D.2 of the Appendix. The L[...]
-
Page 19
® AES/EBU Digital Connector The 386 provides AES/EBU digital output formating through the XLR connector . Be sure to use short lengths of 110 Ω digital cables rather than standard XLR to XLR cables. Using the correct cables will pre- vent digital dropouts and other interconnection problems. S/PDIF Digital Connector The 386 provides S/PDIF digita[...]
-
Page 20
Digital Applications ® 12 Section 3 386 Rear P anel Connections • Connect the source to the desir ed 1/4” TRS or XLR input. • Connect the AES/EBU or S/PDIF output of the 386 and run into the AES/EBU or S/PDIF input inter face of the DA W (CPU). Fr ont Panel Digital Output F eatures 1). Use the METER switch to select digital output metering. [...]
-
Page 21
® Rear P anel Connections • Connect the source to the desir ed 1/4” TRS or XLR input jack. • Connect the AES/EBU or S/PDIF output of the 386 and run into the AES/EBU or S/PDIF input of the digital mixer . Fr ont Panel Digital Output F eatures 1). Use the METER switch to select digital output metering. 2). Use the DITHER switch to select the [...]
-
Page 22
Digital Applications ® 14 Section 3 386 Rear P anel Connections • Connect the source to the desir ed 1/4” TRS or XLR input. • Connect the AES/EBU or S/PDIF output of the 386 and run into the AES/EBU or S/PDIF input interface of the DA W (CPU). Fr ont Panel Digital Output F eatures 1). Use the METER switch to select digital output metering. 2[...]
-
Page 23
® Rear P anel Connections • Connect the source to the desir ed 1/4” TRS or XLR input jack. • Connect the AES/EBU or S/PDIF output of the 386 and run into the AES/EBU or S/PDIF input of the digital mixer . Fr ont Panel Digital Output F eatures 1). Use the METER switch to select digital output metering. 2). Use the DITHER switch to select the [...]
-
Page 24
Digital Applications ® 16 Section 3 386 The 386 gives you the unique option of utilizing the analog and digital outputs simultaneously. This option is ideal for using the analog output section as a r eference monitoring signal of the dig- ital signal. Both analog and digital outputs offer independent output control, which allows you to send a digi[...]
-
Page 25
APPENDIX Sync Input Info Block Diagram dbx T ype IV™ White Paper Noise-Shaping Algorithms T runcation Specifications ® APPENDIX Appendix 386[...]
-
Page 26
Sync Input Info ® 18 Appendix A 386 The dbx 386 comes with the word input 75 Ω te rminated. For certain configurations, you may wish to have the sync input be unterminated. Certain "house sync" configurations will r equire you to change the default position of the termination jumper on the main circuit board. For example, if you run yo[...]
-
Page 27
® Microphone Input +48V Low 20dB Pad Phase In vert Low Cut dbx TYPE IV Conversion System DSP Dither Sample Rate Wo r d Length Output Format Shape Peak LED Line/Mic 12AU7 T ube Drive Analog Output Level Analog Outputs Digital Output Level Rear Panel Line Input Front Panel Instrument Input Bargraph Meter Analog Digital + - Insert dbx Pulsar Chip W o[...]
-
Page 28
T ype IV™ White P aper ® 20 Appendix C 386 dbx T ype IV™ Con version System White P aper b y Roger Johnson The dbx Type IV™ Conversion System is a proprietary analog-to-digital (A/D) conversion process that combines the best attributes of digital conversion and analog recording processes to preserve the essence of the analog signal when it i[...]
-
Page 29
® to-noise performance since the signal is now closer to the noise floor . Because users of digital equipment have to be extremely car eful not to exceed 0 dB FS (full-scale), they must use peak-reading headroom meters. On the other hand, the for giving nature of analog tape allows users of analog r ecording equipment the luxury of only needing to[...]
-
Page 30
T ype IV™ White P aper ® 22 Appendix C 386 Fig. 2 illustrates the mapping function in a differ ent way. Input levels are shown on the left of the graph, while con- verted levels are shown on the right. Notice the mapping of lar ge signal excursions to the 4 dB “Type IV™ Over Region.” One might question the validity of such an approach—tr[...]
-
Page 31
® Figure 3b - Signal of Fig. 3a Going Bey ond the A/D Clip Lev el Amplitude Time A/D Clip Lev el A/D Clip Lev el Figure 3a - Signal Having Low and High F requency Content Amplitude Time T ype IV™ White P aper Appendix C 386 23 386 User Manual[...]
-
Page 32
T ype IV™ White P aper ® 24 Appendix C 386 Now you’re p robably wondering, “What’s the catch? I can’t get something for nothing so what did I give up?” Y ou may be worried that your A/D noise floor got 4 dB worse because we borrowed the top 4 dB of your converter . This is certainly a valid concern. Fortunately, we have the answer! Wit[...]
-
Page 33
® 16-Bit TPDF dither . (a) Shape “off”, (b) with shape set to “S1”, (c) with shape set to “S2.” Parameters: Input -60dBFS, 1 kHz; FFT Length= 2048, Sample Rate= 48 Khz, A verages= 32; Graph Steps= 1024. (a) 24-Bit word, (b) 16-Bit truncated output, no dither . Parameters: Input -60dBFS, 1 kHz; FFT Length= 2048, Sample Rate= 48 Khz, A v[...]
-
Page 34
Appendix ® 26 Appendix D 386 Microphone Input Connector: Female XLR Pin 2 Hot Type: Electronically balanced/unbalanced Impedance: 330 Ω Maximum Input Level: -9 dBu or +11 dBu with 20 dB pad engaged CMRR: >40dB, Typically 55dB Equivalent Input Noise: Typically -120 dBu with a 150 Ω source l oad, 20Hz to 20kHz BW Line Input (Rear Panel) Conne[...]
-
Page 35
® ® 8760 South Sandy Pkwy . Sandy , Utah 84070 Phone: (801) 568-7660 F ax: (801) 568-7662 Int’l F ax: (603) 672-4246 Questions or comments? E•mail us at: customer@dbxpr o .com or visit our W orld Wide W eb home pag e at: www .dbxpro .com A Harman International Company 18-0098-A[...]