Go to page of
Similar user manuals
-
Switch
Dell MXL 10/40GbE
1094 pages 24.06 mb -
Switch
Dell 201S
4 pages 0.08 mb -
Switch
Dell 6248P
34 pages 0.21 mb -
Switch
Dell PC2708
84 pages 1.17 mb -
Switch
Dell 2016, 2024
46 pages 0.89 mb -
Switch
Dell 5324
72 pages 1.27 mb -
Switch
Dell 200S
4 pages 0.08 mb -
Switch
Dell PowerConnect 2016, 2024
46 pages 0.93 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Dell 6248P, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dell 6248P one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Dell 6248P. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Dell 6248P should contain:
- informations concerning technical data of Dell 6248P
- name of the manufacturer and a year of construction of the Dell 6248P item
- rules of operation, control and maintenance of the Dell 6248P item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dell 6248P alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dell 6248P, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dell 6248P.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Dell 6248P item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Dell™ PowerConnect™ 6224/ 6224F/6224P/6248/6248P PowerConnect 6224/6224F/6224P/6248/6248P Release Notes Date: May 2010 System Firmwar e Version 3.2.0.6 Information in th is document is subject to change w ithout notice. © 2003 – 2010 Dell Inc. All rights reserved. Reproduction in any manner whatsoever wit hout the wr itten perm ission of Del[...]
-
Page 2
i i System Firmware V ersi on 3. 2.0 .6 Table of Contents Introduction 1 Global Support 1 Firmware Specifi cations 1 Hardware Suppor ted 2 Added Functiona lity in this Rele ase 3 Changed Functio nality in this Release 11 Deprecated Commands and Parameters 15 Issues Resol ved 17 CLI Reference Manual Updates 21 User’s Gui de Updates 24 Known Issues[...]
-
Page 3
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 1 Introduction This document provides specific informa tion for the Dell PowerConnect 6200 Ser ies switches, firmware v ersion 3.2.0.6. It is recommended that this release note be thoroughly re viewed prior to installing or upgrading of t his product. Glob[...]
-
Page 4
2 System Firmware V ersi on 3. 2.0.6 Firmware Image Name Version No. Release Date PC6200v3.2.0.6.stk 3.2.0.6 May 2010 Version Numbering C onvention Version number Description 6200 Series 3 2 0 6 Four part version number Denotes the build number. Denotes an ad hoc release of the product software. Denotes a scheduled maintenance release o[...]
-
Page 5
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 3 Added Functionality in this Release ¾ Non-Stop F orwarding This feature creates an optio n to allo w the forwardi ng plane o f stack units to c ontinue to f orward packets while the control and manage ment planes restart as a re sult of a power failure,[...]
-
Page 6
4 System Firmware V ersi on 3. 2.0.6 ¾ Serviceability Tracing Commands Debug comm ands provi ded to enable t racing of vari ous protoc ols. ¾ Faster Initialization for Stacking Failo ver Fast Reinitialization invo lves improvement in: • Detection of M anagement U nit Failure • Building Card M a nage r Dat a base • Application of saved confi[...]
-
Page 7
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 5 ¾ MLD Snooping (RFC2710) In IPv4, Lay er 2 switches ca n use IGMP S nooping to li mit the fl ooding of m ulticast traffic by dynamicall y configuring Layer 2 interfaces so that multicast traffic is forwarded to only those in terfaces associated with IP [...]
-
Page 8
6 System Firmware V ersi on 3. 2.0.6 ¾ RADIUS Enhancem ents • The maxim um number of RADIUS servers supported has i ncreased from three to 32. • RADIUS servers with the sam e name can be use d as Backups (RADIUS Authentication and Accounting server s) • Simultaneous Transactions to Multiple RADIUS Servers • RADIUS Accounting – Allows a c[...]
-
Page 9
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 7 ¾ Ping/Traceroute Enhancem ents New ping opt ions have bee n added to all ow the user t o specify the number and size o f echo requests a nd the interval between echo requests. A ping can now be initiated via SNMP using the MIB defined in RFC 2925. New [...]
-
Page 10
8 System Firmware V ersi on 3. 2.0.6 ¾ Granular OSPF v2/v3 Tra ps Configure which of the OSPF traps the OSPF Router should generate by enab ling or disabling the trap condition. If a trap condition is enabled and the condition is detected, the OSPF router will send the trap to all trap receivers. ¾ auto-cost reference bandwi dth and bandwidth Com[...]
-
Page 11
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 9 ¾ Configure d Tunnels M TU To comply with RFC 4213, Basic Transition Mech anis ms for IPv6 Hosts and Routers, the IPv6 MTU on configured IPv6 over IPv4 tunnels was changed from 1480 bytes to 128 0 bytes. ¾ IPv6 6 to 4 Auto Tun nel s The 6 to 4 tunnels [...]
-
Page 12
1 0 System Firmware Version 3. 2.0.6 ¾ IPv6 Mana gement Enha ncements Provides the following: • Dual IPv4/IP v 6 ope ration over the net wo rk po rt • Static assignm ent of IPv6 add resses and gateways f or the service/ network ports • Ability to ping an IPv6 link-local ad dress over the serv ice/n etwork port • SNMP traps and que ries via[...]
-
Page 13
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 11 Changed Functionality in this Release ¾ Spanning Tree U pdate – 802.1Q -2005 Spanning Tree now supports IEEE802 .1Q-2005. Th is version of the IEEE Multiple Sp ann ing Tree Protocol corrects problems associated with the previou s versio n, provides f[...]
-
Page 14
1 2 System Firmware Version 3. 2.0.6 ¾ ip route Comm and Changed The syntax of the ip route command has changed. The metric keywor d is no longer accepted as it had no effect. The new synta x is: ip route ip addr subnetmask | prefix-length nextHopRtr [ preference ] ¾ distance ospf Comma nd Changed The distance ospf comm and has been change d (for[...]
-
Page 15
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 13 ¾ Trap Configuration In previous versions of the software, configuration of the flags for controllin g traps was scattered about in a number of plac es. snmp-server enable tr aps is now a common c ommand for configur ing al l trap flags. The legacy com[...]
-
Page 16
1 4 System Firmware Version 3. 2.0.6 ¾ ACL Changes The following changes apply to ingress and egress ACLs: o Maximum of 100 ACLs o Maximum rules per ACL are 127 Note: Altho ug h th e max imu m nu mb e r o f ACL s is 100 , an d t h e max imu m nu mb er o f ru les per AC L is 1 2 7, the system cannot support 100 ACLs t hat each has 127 r ules. Note:[...]
-
Page 17
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 15 Deprecated Commands and Parameters The following CLI commands have been deprecated since the 2.x release. Title Description bridge address Interface Configuration mode Rationale: The following par ameters have been depr ecate d: • delete-on-reset • [...]
-
Page 18
1 6 System Firmware Version 3. 2.0.6 Title Description ip osp f Interface Configuration mode Rationale: The ip ospf command has been deprecate d. This functionality has been replaced by the ip ospf area command. ip ospf are aid Interface Configuration mode Rationale: The ip ospf areaid command has been de precat ed. This functionality has been re p[...]
-
Page 19
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 17 Issues Resolved The following is a list of issues resolved in the current firm ware release. Description User Impact Resolution Unable to configure IPv6 host (4001::2) as an SNMP trap receiver on the DUT. User is not aware that the only IPv4 address is [...]
-
Page 20
1 8 System Firmware Version 3. 2.0.6 Description User Impact Resolution Bridge multicast forbidden forward-unregistered caus es L3 Multicast to fail. Flooding in ingress VLAN. Modified the L3 interaction code of snooping to notify the driver when snooping is enabled. When snooping is disabled, the curr ent operational state of snooping i s also sen[...]
-
Page 21
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 19 Description User Impact Resolution Cannot enter Daylight Saving Time from Web interface. In summer time configuration page, in recursive mode, clock zone field is not accepting valid range. In summer time configuration page, in recursive mode, added app[...]
-
Page 22
2 0 System Firmware Version 3. 2.0.6 Description User Impact Resolution Changing Radius Timeout from Web interface inadvertently changes Priority to same value. Changing the Timeout Duration field on the RADIUS Server Configuration web page would also change the Priority field to the same value. Correct the API to properl y set the RADIUS priority.[...]
-
Page 23
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 21 CLI Reference Manual Updates Non-Stop Forwarding Title Description nsf no nsf Use this command to enable non-stop forwarding. The “no” form o f the command will disable NSF. Default: Non-stop forwarding is enabled b y default. show nsf Use this comm[...]
-
Page 24
2 2 System Firmware Version 3. 2.0.6 Title Description show ip ospf neighb or This command has been enhanced to list the per neighbor graceful restart status described in the RFC 4750 MIB. Possible values for Restart H elper Status are as follows: • Helping – This router is acting as a helpful neighbor to this neighbor. • Not Helping – This[...]
-
Page 25
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 23 RADIUS A ccounting Serv ers Title Description radius-server host acct The switches do not support creating accounting server names with the same name although the CLI Reference Manual and User Guide state that it is supported. Default: Not applicable Sp[...]
-
Page 26
2 4 System Firmware Version 3. 2.0.6 Link Dependenc y Commands Title Description link-dependenc y group [ actio n { up | down } ] Use the action command to control the operational state of the group based on the dependent links state. • up — Causes the group members to change their operational state to be opposite that of the dependent link. ?[...]
-
Page 27
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 25 Known Issues Summary User Impact Workaround Non-configuration file getting loaded to startup-config through HTTP. When the switch reboots and attempts to read an invalid start-up configuratio n file, it will give up and create a default startup configur[...]
-
Page 28
2 6 System Firmware Version 3. 2.0.6 Summary User Impact Workaround Bridge multicast address is shown as MAC Address format in show running- config buffer when it is configured in IP format. If a user configures the bridge multicast address as an IP address format in VLAN interface mode, it is displayed in the sho w running-config command in M A C [...]
-
Page 29
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 27 Summary User Impact Workaround ISDP updates are not including Voice VLAN Reply TLV whe n Voice VLAN ID on interface is changed. Upon changing configur ation immediat el y after getting the VLAN assigned, DUT stops advertising Voice VLAN repl y T LV in i[...]
-
Page 30
2 8 System Firmware Version 3. 2.0.6 Known Restrictions and Limitations Layer 2 802.1AB (LLDP) Description User Impact LLDP-MED location and inven t ory transmit TLVs have no effect. The switch does not support configur ing this data so enabling these T LVs has no effect. QoS Description User Impact Traffic permitted by an outbound ACL on one port [...]
-
Page 31
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 29 LACP Description User Impact LAGs Supported Number of LAGs supported: • Up to 18 Dynamic LAGs • 48 Static LAGs Limitations (stack of 12) • Long Timeouts With a minimal CPU load, it takes approximat el y 1.5 minutes with 16 dynamic LAGs and 15 MSTP[...]
-
Page 32
3 0 System Firmware Version 3. 2.0.6 ICMP Description User Impact IPv4 Fragmentation support The switch is not fr agmenting the datagram and forwards even when the IP MTU of the forwarding Interface is set to a lo wer value (than the datagram size). This is a hardware limitation and is working as designed. T he HW does not allow the IP MTU to be co[...]
-
Page 33
PowerConnect 6224/6224F/6224P/6248/6248P Releas e Notes System Firmware Versi on 3.2.0.6 Page 31 Management CLI Description User Impact radius-server mode commands do not have a "no" form. None of the commands i n radius-server mode support a "no" form except for the msgauth command. To reset values to the default, delete the se[...]
-
Page 34
3 2 System Firmware Version 3. 2.0.6 Cable Diagnostics Description User Impact Cable Length Diagnostic sh o ws result as 'Unknown' for a port to which Network is connected. Problem is intermittent and only observabl e whe n con necte d to a D-Link DES1008. File Management Description User Impact Error displayed on conso le while applying [...]