Go to page of
Similar user manuals
-
Personal Computer
Dell E510
2 pages 1.46 mb -
Laptop
Dell 1012
56 pages 1.49 mb -
Projector
Dell 1430X
63 pages 3.79 mb -
Power Supply
Dell K792N
73 pages 0.83 mb -
Printer
Dell dn1
207 pages 2.78 mb -
Laptop
Dell Inspiron 1150
136 pages 1.4 mb -
Computer Monitor
Dell 3008WFP
37 pages 1.49 mb -
Tool Storage
Dell MD3220
74 pages 2.24 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Dell C8000XD, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dell C8000XD one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Dell C8000XD. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Dell C8000XD should contain:
- informations concerning technical data of Dell C8000XD
- name of the manufacturer and a year of construction of the Dell C8000XD item
- rules of operation, control and maintenance of the Dell C8000XD item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dell C8000XD alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dell C8000XD, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dell C8000XD.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Dell C8000XD item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Dell PowerEdge C8000XD Hardware Owner’s Manual Regulatory Model: B06B Regulatory T ype: B06B002[...]
-
Page 2
Notes, Cautions, and W arnings NOTE: A NOTE indicates important information that helps you make b etter use of your computer. CAUTION: A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed. WAR NI NG : A WARNING indicates a potential for property damage, personal injury , or death. ______________ ______ I[...]
-
Page 3
Contents 3 Contents 1 About Your System . . . . . . . . . . . . . . . . . . 7 Front-Panel Features and Indicators . . . . . . . . . . . 7 Hard-Drive Features . . . . . . . . . . . . . . . . . . . . 9 Hard-Drive Bay Numbering . . . . . . . . . . . . . . 9 Hard-Drive Indicator Patterns . . . . . . . . . . . 10 SAS Connectors Features . . . . . . . . [...]
-
Page 4
4 Contents Sled Blank . . . . . . . . . . . . . . . . . . . . . . . . 31 Removing a Sled Blank . . . . . . . . . . . . . . . 31 Installing a Sled Blank . . . . . . . . . . . . . . . 32 Hard-Drives . . . . . . . . . . . . . . . . . . . . . . . . 32 Hard-Drive Configuration . . . . . . . . . . . . . . 32 Hard-Drive Installation Guidelines . . . . . .[...]
-
Page 5
Contents 5 Removing the Hard-Drive Backplane From an Expansion Hard-Drive Carrier . . . . . . . 50 Installing a Hard-Drive Backplane Into an Expansion Hard-Drive Carrier . . . . . . . . . . 51 3 Troubleshooting . . . . . . . . . . . . . . . . . . . 53 Safety First—For Y ou and Y our Sy stem . . . . . . . . . 53 Installation Problems . . . . . . .[...]
-
Page 6
6 Contents Cabling Configurations . . . . . . . . . . . . . . . . . . 62 Expander Firmware File Names . . . . . . . . . . . . . 63 Expander Firmware Update Guidelines . . . . . . . . . 65 Updating the Expander Firmware . . . . . . . . . . . . 65 5 Jumpers and Connectors . . . . . . . . . . . . 71 Hard-Drive Backplane Connectors . . . . . . . . . . [...]
-
Page 7
About Your System 7 1 About Y our Sy stem Front-Panel Features and Indicators Figure 1-1. Front-Panel Features and Indicators Item Indicator , Button, or Connector Icon Description 1 Handle Hold to pull the hard-drive cage from the sled. 1 2 3 4 5 6 7 8 9 10 11[...]
-
Page 8
8 About Your System 2 External mini-SAS connector A2 Connects to a compute sled’s host bus adapter (HBA) or RAID car d. When you configure zoning for the storage sled, the external mini-SAS connector becomes zone group 0. 3 External mini-SAS connector A1 Connects to a compute sled’s host bus adapter (HBA) or RAID car d. When you configure zonin[...]
-
Page 9
About Your System 9 Hard-Drive Features The C8000XD storage sled is available with 12-drive or 24-drive option. All hard-drives ar e mounted in special hard -drive carriers and connect to the hard-drive backplane inside the sled. • Standard hard -drive carrier supports 3. 5-inch SAS/SA T A/SSD hard-drive. • Flexible har d-drive carrie r support[...]
-
Page 10
10 About Your System Figure 1-3. 24-Drive Bay Numberi ng Hard-Drive Indicator Patterns The C8000XD sled hard-drive backplanes include a hard-drive activity LED and two bi-color ed hard-drive status and fault LEDs per drive. The state of the hard-drive backplane indicators ale rts you to the condition of the har d- drives in th e sled. Y ou can view[...]
-
Page 11
About Your System 11 12-Drive Bay Hard-Drive Indicators Figure 1-4. 12 -Drive Bay Hard-Drive Indicators—Left Side Hard-Drive Cage Figure 1-5. 12 -Drive Bay Hard-Drive Indicators—Right Side Hard-Drive Cage NOTE: Group A in the illustrations indicate th e grouping of the hard-drives in the single port mode configuration. The illust ration above s[...]
-
Page 12
12 About Your System 24-Drive Bay Hard-Drive Indicators Figure 1-6. 24-Drive Bay Har d-Drive Indicators—Left Side Hard-Drive Cage Figure 1-7. 24-Drive Bay Har d-Drive Indicators—Right Side Hard-Drive Cage NOTE: Group A and Group B in the illustrations indicate the grouping of the hard- drives in an expansion mode (zoning or non- zoning) configu[...]
-
Page 13
About Your System 13 * This conditio n is not supported in LSI HBA/RAID cards. When you abort the RAID rebuild process, the hard-drive LED blinks ambe r to indica te drive failu re. Icon Indicator Hard-drive activity indicator Hard-drive status indi cator Hard-drive fault indica tor T able 1-1. Hard-Drive Indicator Patterns Condition Hard-Drive Act[...]
-
Page 14
14 About Your System SAS Connectors Features The storage sled has two SASx28 expander chips on the SAS expander . Each expander chip, labeled LSI 28 port 6 GB expander A/B port in F igure 1-8, has its own unique SAS address and conne cts to two inter nal mini-SAS connectors and two e xternal mini-SAS connectors. The external mini-SAS connectors sup[...]
-
Page 15
About Your System 15 Figure 1-8. SAS Expander Board SAS Expander Board[...]
-
Page 16
16 About Your System Expander Configura tion Mode The C8000XD sled is equi pped with a SAS expander to operate the har d - drives in single port, dual port, or ex pansion mode. Use mini -SAS x4 cable(s) to connect a compute sled to your C8000XD sled. The sled supports the following configuration modes. •S i n g l e p o r t m o d e In single port [...]
-
Page 17
About Your System 17 The figure below shows a s ingle path connection from single-HBA/RAID compute sled to two cascaded storage sleds. In this mode, the hard-drives in the two storage sleds are cascaded for extended storage capacity . Figure 1-10. Single Host to Cascaded Storage Sled Connection Single-HBA/RAID Compute Sled Storage Sled 2 Storage Sl[...]
-
Page 18
18 About Your System •D u a l p o r t m o d e In dual port mode, the storage sled SAS expander board supports 12 x 2.5 or 3.5-inch SAS hard-drives from a dual-cable conn ection. The figure below shows a dual path connection from a dual-HBA compute sled connected to the storage s led’s external mini-SAS A1 and B1 connectors. This mod e delivers [...]
-
Page 19
About Your System 19 • Expansion mode (non-zoning) In expansion mode, the storage sled SAS expander board supports 24 x 2.5 SSD hard-drives from a d ual-cable connection. The figure below shows a d ual path connection from a single-RAID compute sled connected to the storage sled’s externa l mini-SAS A1 and A2 connectors. In this mode, the hard-[...]
-
Page 20
20 About Your System • Expansion mode (four zones) In expansion mode with four zone s configuration, the storage sled SAS expander board supports 24 x 2.5 SSD hard-drives from a single -cable connection. The SA S connec tions ar e grouped into four zones (A1/Zone 0, A2/Zone 1, B1/Zone 2, B2/Zone 3) and each zone allows the host/compute sled to ac[...]
-
Page 21
About Your System 21 • Expansion mode (two zones) In expansion mode with two zones configuration, the storage sled SAS expander boar d supports 12 x 3.5 SAS/SA T A hard-drives from a single- cable connection. The SAS connecti ons are grouped into two zones (A1/Zone 0 and A2/Zone 1) and each zo ne allows the host/compute sled to access a group of [...]
-
Page 22
22 About Your System Service T ag The following illustration provides loca tion of the Servi ce T ag number on the C8000XD storage sled. Figure 1-17. Service T ag Location for C8000XD Storage Sled[...]
-
Page 23
About Your System 23 Other Information Y ou May Need WAR NI NG : See the safety and regulatory info rmation that shipped with your sy stem. Warranty information may be in cluded within this document or as a separate document. • The Getting Started Guide provides an overview of rack installation, system features, setting up your sy stem, and techn[...]
-
Page 24
24 About Your System[...]
-
Page 25
Installing System Components 25 2 Installing Sy stem Components Safety Instructions WAR NI NG : W orking on sy stems that are st ill connected to a power su pply can be extremely dangerous. CAUTION: Sy stem components and electronic circuit boards can be damaged by discharge of static electricity . CAUTION: Many repairs may only be done by a certif[...]
-
Page 26
26 Installing System Components • Some cables have a conn ector with locking tabs; if you ar e disconnecting this type of ca ble, press in on the locking tabs before you disconnect the cable. As you pull connectors apart, keep them evenly aligned to avoid bending any connector pins. A lso , before you connect a cable, ensure that both connectors [...]
-
Page 27
Installing System Components 27 Inside the Sy stem CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troublesho oting and simple re pairs as authorized in your product documentation, or as directed by the on line or telephone service and support team. Damage due to servicing that is not authorized is[...]
-
Page 28
28 Installing System Components Sled Opening the Sled CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troubleshooting and si mple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized i[...]
-
Page 29
Installing System Components 29 Closing the Sled 1 P u sh the har d-drive cage all the way in to the sled until the hard-drive cage release latch snaps into place. See F igure 2-2. 2 If you pulled the hard-drive cage to the fully e xtended position, slide the rail release latches on each side of the hard-drive cage and push the hard- drive cage int[...]
-
Page 30
30 Installing System Components Removing a Sled CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troubleshooting and si mple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not authorized is not [...]
-
Page 31
Installing System Components 31 Installing a Sled CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troublesho oting and simple re pairs as authorized in your product documentation, or as directed by the on line or telephone service and support team. Damage due to servicing that is not authorized is [...]
-
Page 32
32 Installing System Components Installing a Sled Bla nk Hold the blank with the guide rail faci ng forward. Slide the blank into the enclosur e until it is fully seated and the releas e latches snap into place. See Fi g u re 2 - 5 . Hard-Drives The information in this section includes replacement procedur es for the following: • Standar d hard-d[...]
-
Page 33
Installing System Components 33 The following table shows the har d-drive carrier type and har d-drive size, type, and height, and drive capacity for a supporte d configu ration. NOTE: X in the following table indicates not supported. NOTE: See "Expander Configuration Mode" on page 15 for more information on the expander configuration mod[...]
-
Page 34
34 Installing System Components Standard Hard-Drive Carrier Use a standard har d-drive carrier to install 3.5-inch SAS/SA T A/SSD hard- drive into th e sled. Removing a Standard Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troubleshooting and si mple repairs as authorized in y[...]
-
Page 35
Installing System Components 35 Figure 2-6. Removing and Installing a Stan dard Hard-Drive Carrier Installing a Standard Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troublesho oting and simple re pairs as authorized in your product documentation, or as directed by the on line[...]
-
Page 36
36 Installing System Components Removing a 3.5-inch Hard-Drive From a Standard Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troubleshooting and si mple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Dama[...]
-
Page 37
Installing System Components 37 Figure 2-7. Removing and Installing a 3.5-inch Hard-Drive From a Standard Hard-Drive Carrier Installing a 3.5-inch Hard-Drive In to a Standard Ha rd-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troublesho oting and simple re pairs as authorized in yo[...]
-
Page 38
38 Installing System Components 3 Flex the standar d hard-drive carrier’s right-side rail and insert the carrier pins into the hard-drive assembly’s mounti ng holes and then fle x the left- side rail and ins ert the carrier pins into the other mounting holes. 4 F it the t-shaped end of the carrier st rap handle into the notch and then twist to [...]
-
Page 39
Installing System Components 39 Figure 2-8. Removing and Installing a Flexible Hard-Drive Carrier Installing a Flexible Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troublesho oting and simple re pairs as authorized in your product documentation, or as directed by the on line [...]
-
Page 40
40 Installing System Components Removing a 2.5-inch Hard-Drive From a Flexible Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troubleshooting and si mple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Dama[...]
-
Page 41
Installing System Components 41 Figure 2-9. Removing and Installing a 2.5-in ch Hard-Drive From a Flexible Hard-Drive Carrier Installing a 2.5-inch Hard-Drive In to a Flexible Hard-Drive Carr ier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troublesho oting and simple re pairs as authorized in y[...]
-
Page 42
42 Installing System Components Expansion Hard-Drive Carrier An expansion har d-drive carrier mounts two 2.5-inch SSD hard-drive carriers. There ar e two ways to remove the 2.5- inch SSD har d-drive, you can remove the SSD hard-drive di re ctly from the sled (see "Removing a SSD Har d-Drive Carrier" on page 44) or r e move the e xpa nsion[...]
-
Page 43
Installing System Components 43 Figure 2-10. Removing and Installing an Expansion Hard-Drive Carrier Installing an Expansio n Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troublesho oting and simple re pairs as authorized in your product documentation, or as directed by the on[...]
-
Page 44
44 Installing System Components Removing a SSD Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troubleshooting and si mple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damage due to servicing that is not [...]
-
Page 45
Installing System Components 45 Figure 2-11. Removing and Installing a SSD H ard-Drive Carrier Installing a SSD Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troublesho oting and simple re pairs as authorized in your product documentation, or as directed by the on line or telep[...]
-
Page 46
46 Installing System Components Removing a 2.5-inch SSD Hard-Drive From a SSD Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troubleshooting and si mple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team. Damag[...]
-
Page 47
Installing System Components 47 Figure 2-12. Removing and Installing a 2.5-inch SSD Hard-Drive from the SSD Hard- Drive Carrier Installing a 2.5-inch SSD Hard-Dri ve Into a SSD Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troublesho oting and simple re pairs as authorized in y[...]
-
Page 48
48 Installing System Components 3 Flex the right-side rail and insert the carrier pins into the hard-drive assembly ’s mounting holes and then fle x the left-side rail a nd insert the pins into the other mounting holes. 4 F it the t-shaped end of the carrier st rap handle into the notch and then twist to lock the strap handle. See Figur e 2-12. R[...]
-
Page 49
Installing System Components 49 Figure 2-13. Removing and Installing a SSD Hard-Drive Carrier from an Expansion Hard-Drive Carrier Installing a SSD Hard-Drive Carrier Into an Expansion Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troublesho oting and simple re pairs as authori[...]
-
Page 50
50 Installing System Components Removing the Hard-Drive Backplane From an Expansion Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troubleshooting and si mple repairs as authorized in your product documentation, or as directed by the online or telephone service and support team.[...]
-
Page 51
Installing System Components 51 Figure 2-14. Removing and Installing a Ha rd-Drive Backplane from an Expansion Hard-Drive Carrier Installing a Hard-Drive Backplane In to an Expansion Hard-Drive Carrier CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform troublesho oting and simple re pairs as authorize[...]
-
Page 52
52 Installing System Components 3 Flex the expansion har d-drive carrier ’s right-side rail and insert the carrier pins into hard-drive tray’s mounting holes and then flex the left-side rail and insert the carrier pins into the other mounting holes. See F igu r e 2-14. 4 Install the SSD hard-drive s. See "Insta lling a SSD Hard-Drive Carri[...]
-
Page 53
Troubleshooting 53 3 T roubleshooting Safety First—For Y ou and Y our Sy stem WAR NI NG : Whenever you need to lift the sy stem , get others to assist you. T o avoid injury , do not attempt to lift the sy stem by yourself. WAR NI NG : Before removing the sy stem cov er , disconnect all power , then unplug the AC power cord, and then disconnect al[...]
-
Page 54
54 Troubleshooting • If the system does not power on, chec k the LED display . If the power LED is not on, you may not be receiving A C power . Check the AC power cord to make sur e that it is securely connec ted. T roubleshooting External Connections Ensure that all external cables are secur ely attached to the external connectors on your sled b[...]
-
Page 55
Troubleshooting 55 Hard-Drive Not Recognized 1 Open the sled. See "Opening the Sled" on page 28. 2 Check the power an d mini-SAS data cable connection . Ensure that the cables are firmly seated in their co nnectors on the hard-drive backplane and the SAS expander board. Or , ch eck the connector pins for damage. 3 Check the status LED ind[...]
-
Page 56
56 Troubleshooting 6 Close the sled. See "Closi ng the Sled" on page 29. 7 If the problem persists, install a new hard-drive. If the problem is not r esolved, see "Getting Help" on page 77. T roubleshooting the SAS Expander Board CAUTION: Many repairs may only be done by a certified service technician. Y ou should only perform t[...]
-
Page 57
Troubleshooting 57 3 Ensure that the power , mini-SAS data, and signa l cables are firmly seated in their connectors on the SAS expander boar d and node power distribution board. Or , check the connector pins for damage. 4 Ensure that the SAS e xpander boar d is installed properly in the sled. 5 Reinstall the sled into the enclosur e. S ee "In[...]
-
Page 58
58 Troubleshooting 3 Ensur e that the node power distribution boar d is installed properly in the sled. 4 Reinstall the sled into the enclosure. See "Installing a Sled" on page 31. If the problem persists, see "Getting Help" on page 77. Checking the Expander Firmware V ersion NOTE: Download and install the latest expander firmwa[...]
-
Page 59
Using the Expander Flash Utility 59 4 Using the Expander Flash Utility Expander Flash Utility (Xfl ash) is a command-line ut ility that you can use to identify the SAS address of the SAS e xpander , determine the expander firmware version, r eset the SAS expa nder , or update the two SAS e xpander chips simultan eously or s eparately . Hardware and[...]
-
Page 60
60 Using the Expander Flash Utility Command Description Use the following syntax fo r Xflash utility commands: xflash [OPTIONS ] [INTERF ACE] [COMMAND] Use a space to separate the program na me, the options, the interface and the command fields. Command Line Paramete rs The following tables list the commo n Xflash commands used in this docume nt. N[...]
-
Page 61
Using the Expander Flash Utility 61 a. If specified, [REGION] (decimal ) refers to a ny expander flash regi on (0 to 9). If not s pecified, the image is down loaded into the fla sh region design at ed to rece ive firmware or manufa cturing updates. b. If specified, [REGION] (decimal ) refers to a ny expander flash regi on (0 to 9). If not s pecifie[...]
-
Page 62
62 Using the Expander Flash Utility Cabling Configurations The expander firmwar e update can be done via the inband SAS port by connecting a mini-SAS cabl e(s) between the stor age sled and compute sled. Y ou can choose from t he following cabling options when updating the expander firmwar e. • 1 Expander A/B — Single-HB A/R AID host dir ect co[...]
-
Page 63
Using the Expander Flash Utility 63 • 4 Expander A/B — F our single-RAID ho sts direct connection to a 24-drive sled In this configuration, the four hosts are connected to the storage sled and the 24 har d-drives are grouped into four zones. Expander chip A controls zones 0 and 1 and expander chip B cont rols zones 2 and 3. See F igure 1-13. Th[...]
-
Page 64
64 Using the Expander Flash Utility Note: XXX represents the version number of the firmware image for flash region 2. Note: XXX represents the version number of the manufacturing image for flash region 3. Note: 1 represents the configurati on type and expander chip pr operties. XXX represents version number of the manufacturi ng image for flash reg[...]
-
Page 65
Using the Expander Flash Utility 65 Expander Firmware Update Guidelines The following are the recommended guidelines for updating the expander firmw are. • F irmware update must be downloaded in each flash r egion starting with flash region 0. • Do not erase the expander firmwar e fl ash image when the firmwar e update is in progress, this clea[...]
-
Page 66
66 Using the Expander Flash Utility The storage sled’s SAS expander will be identified and the expander chips and the two unique SAS addr esses are listed. Sample output: NOTE: The storage sled's SAS expander has two unique SAS addresses. If you cannot find the SAS address, you can use the RS232 COM port to establish connection between the c[...]
-
Page 67
Using the Expander Flash Utility 67 F or example, the command line should have the following format: cmd>xflash -i 500650b0000472bf down fw sas2xfwZeus_120518_1_0_ 2_0.fw 0 b When the "Are you sur e to download file to e xpander? (y/n)" message prompt appears, press Y . 8 Download the expander firmware to flash r e gion 2. a Enter the [...]
-
Page 68
68 Using the Expander Flash Utility 10 Download the manufacturing image to flash region 9. a Enter the following command: cmd>xflash -i SASADDR down mfg sas2xMfgZeus_ X _Region9_ XXX .bin 9 wher e SASADDR is the inband SAS addres s of the specified expander chip XXX is the configuration typ e and expander property Region9_X is the manufacturing [...]
-
Page 69
Using the Expander Flash Utility 69 15 Check the region 0 firmwar e version by entering the command: cmd>xflash –i SASADDR get ver 0 16 Check the region 2 firmwar e version by entering the command: cmd>xflash –i SASADDR get ver 2 17 Check the region 3 manufacturing version by entering the command: cmd>xflash –i SASADDR get ver 3[...]
-
Page 70
70 Using the Expander Flash Utility[...]
-
Page 71
Jumpers and Connectors 71 5 Jumpers and Connectors Hard-Drive Backplane Connectors Figure 5-1. Left Hard-Drive Backplane 1 onboard SAS/SATA connector 0 or 12 2 onboard SAS/SATA connector 2 or 14 3 backplane-bridge board connector 4 onboard SAS/SATA connector 3 or 15 5 onboard SAS/SATA connector 1 or 13[...]
-
Page 72
72 Jumpers and Connectors Figure 5-2. Right Hard-Drive Backplane 1 backplane-bridge board connector 2 onboard SAS/SATA connector 6 or 18 3 power sensor connector 4 p ower connector 5 onboard SAS/SATA connector 8 or 20 6 onboard SAS/SATA connector 10 or 22 7 mini-SAS connector 0 8 mini-SAS connector 1 9 expander I2C connector 10 mini-SAS connector 2[...]
-
Page 73
Jumpers and Connectors 73 Figure 5-3. Expansion Hard-Drive Carrier Hard-Drive Backplane 1 onboard SSD connector 1 2 onboard SSD connector 2[...]
-
Page 74
74 Jumpers and Connectors SAS Expander Board Connectors Figure 5-4. SAS Expander Board Connectors 1 external mini-SAS connectors A1 and A2 2 smart debug co nnector for controller 2 3 internal mini-SAS connector 3 4 internal mini-SAS connector 2 5 internal mini-SAS connector 1 6 internal mini-SAS connector 0 7 power connector 8 expander I2C connecto[...]
-
Page 75
Jumpers and Connectors 75 Node Power Distribution Board Connectors Figure 5-5. Node Power Distribution Board Connectors 1 power/emergency throttling connector 2 I2C connector 3 12 V S2 power connector 4 HDD1 power connector 5 power connector 6 HDD3 power connector 7 HDD2 power connector 8 system board power connector 9 12 V S1 power connector 10 re[...]
-
Page 76
76 Jumpers and Connectors[...]
-
Page 77
Getting Help 77 6 Getting Help Contacting Dell F o r customers in the United States, call 800- WWW -DELL (800-9 99-3355). NOTE: If you do not have an active Inte rnet connection, you can find contact information on your purchase invoice, packi ng slip, bill, or Dell product catalog. Dell provides several online and telepho ne-based support and serv[...]
-
Page 78
78 Getting Help[...]
-
Page 79
FILE LOCATION: D:ProjectsUser GuideServerDellOOB HOMHardware Owners ManualDWS Sled C8000XDC8000XD_HOM_bk0IX.fm Index 79 Index Numerics 2.5-inch hard-drive installing, 4 1 re mo vi n g, 4 0 2.5-inch SSD hard-drive installing, 4 7 - 4 8 re mo vi n g, 4 6 3.5-inch hard-drive installing, 3 7 - 3 8 re mo vi n g, 3 6 A about you r system, 7 C c[...]
-
Page 80
FILE LOCATION: D:ProjectsUser GuideServ erDellOOBHOMHardware O wners ManualDWS SledC8000XD C8000XD_HOM _bk0IX.fm 80 Index H hard-driv e configuration, 32 I indicator power , 8 system identi ty , 8 installing 2.5-inch har d-drive, 4 1 2.5-inch SSD har d-drive, 4 7 - 4 8 3.5-inch har d-drive, 3 7 - 3 8 expansion carrier backplane, 5 1 expan[...]
-
Page 81
FILE LOCATION: D:ProjectsUser GuideServerDellOOB HOMHardware Owners ManualDWS Sled C8000XDC8000XD_HOM_bk0IX.fm Index 81 T troubleshooting expander boar d, 5 6 expander connectors, 5 6 external connections, 5 4 firmware version, 5 8 hard-drive, 5 4 hard-drive backplane, 5 7 NPDB, 5 7 X Xflash See Expander Flash Utility[...]
-
Page 82
FILE LOCATION: D:ProjectsUser GuideServ erDellOOBHOMHardware O wners ManualDWS SledC8000XD C8000XD_HOM _bk0IX.fm 82 Index[...]