Go to page of
Similar user manuals
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Dell PC8024F, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dell PC8024F one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Dell PC8024F. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Dell PC8024F should contain:
- informations concerning technical data of Dell PC8024F
- name of the manufacturer and a year of construction of the Dell PC8024F item
- rules of operation, control and maintenance of the Dell PC8024F item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dell PC8024F alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dell PC8024F, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dell service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dell PC8024F.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Dell PC8024F item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
DELL P owerConnect™ PCM6220/P CM8024/PCM6348 PCM8024 -k/PC8024/ PC8024F/PC7000 Serie s Firmware CLI T ransition Guide A Dell Technical White Paper[...]
-
Page 2
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page ii Notes, Notices, and Cautions A NOTE indicates import ant information that helps you make better use of your computer. A NOTICE i ndicates either pot ential damage to ha rdware or loss of data a nd tells you ho w to a void the pr oblem. A CAUTION in dicates a po tential fo[...]
-
Page 3
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 1 Contents A Del l Tec hnical W hit e Paper ......................................................................................... i Introduction ................................................................................................................. 2 Changes to[...]
-
Page 4
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 2 Introduction The Dell™ Po werCon nect CLI Transiti on Guide Whi te Paper d iscusses the changes in th e CLI commands from the Powe rConnect 6200 an d 8024 3.x softwar e to the 4. x software release on the 6200, 7000, and 8000 Series switc hes. Some changes were syn tacti[...]
-
Page 5
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 3 Port Channel Interfaces Port-cha nnel (o r LAG) i nterfaces are repres ented in t he CLI by the vari able port -chan nel-numbe r, which c an assume values from 1– 48. When lis ted in com mand line out put, po rt chann el interf aces ar e preced ed by the cha racters Po .[...]
-
Page 6
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 4 Management Interfaces There is no longe r a preco nfigure d manageme nt VLAN on the swit ch. Eff ective wi th the 4.x so ftware, the adm inistra tor can co nfig ure a ma nagement VLAN on the in- band int erfaces , but t he VLAN s hould not be ena bled fo r routing . The ip[...]
-
Page 7
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 5 Updated Commands – Opera tional Modifications Feature Previous Implementation Dell™ PowerConnect 4.x Implementation Comment s ARP arp tim eout seco nds arp tim eout seco nds In the revi sed impl ementatio n, the command is supported i n both Global Configuration Mode a[...]
-
Page 8
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 6 Feature Previous Implementation Dell™ PowerConnect 4.x Implementation Comment s IPv6 R outing show ipv6 rou te summary [all] show ipv6 rout e summary [best] Use best to display the count summary for only best routes. IP Rout ing show ip interface show ip int erface The o[...]
-
Page 9
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 7 Feature Previous Implementation Dell™ PowerConnect 4.x Implementation Comment s User Interface Exit Exit In User EXEC mode, this command behaves identica lly with the quit comma nd, closing an active t erminal session b y logging off the switch. Virtual Router Redundancy[...]
-
Page 10
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 8 Updated Commands – Command Mode Modifications Feature Previous Implementati on Dell™ PowerConnect 4.x Implementation Comments ARP arp timeout se conds a rp timeout seco nds In the revised im plementation, the command i s supported i n both Global Configuration Mode and[...]
-
Page 11
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 9 Feature Previous Implementati on Dell™ PowerConnect 4.x Implementation Comments IPv6 R outing show ipv6 interface { brief| loopback loo pback-id | tunnel tunnel-id | vlan vlan- id [p refix]} show ipv6 in terface [ brief] [loopback loo pback-id | tunnel tunnel-id | vlan v[...]
-
Page 12
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 10 Updated Commands – Syntax Modifications Feature Previous Implementa tion Dell™ PowerConnect 4 .x Implementati on 802.1x dot1x timeout re-authperiod seconds dot1x tim eout reau th-period s econds 802.1x dot1x re- authentication dot1x reauth entication 802.1x dot1x mult[...]
-
Page 13
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 11 DNS Client Enhancements The following command s are modifi ed to allow spaces in ho st names. Global Configuration Mode Commands: radiu s-server host [ a cct | auth ] { i p–address | hostname } tacacs-serv er host {ip- address|host name} sntp serv er {ip- address | ipv [...]
-
Page 14
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 12 IGMP ip igmp q uery-max- response- time tenthsofseconds ip igmp q uery-max- response- time seconds IGMP show ip ig mp interface v lan vlan-id show ip igmp interface [ interface- type interface-number] IGMP show ip ig mp groups int erface vlan v lanid [detail] show ip igmp[...]
-
Page 15
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 13 OSPF area ar ea-id virtual-link neighbor-id area area -id virtual-link neighbor-id dead- interval se conds area area -id virtual-link neighbor-id hello- interval se conds area area -id virtual-link neighbor-id retransmit- interval second s area area -id virtual-link neigh[...]
-
Page 16
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 14 OSPFv3 area area-id virtua l-link neighbor-id area area -id virtual-link neighbor-id dead- interval se conds area area -id virtual-link neighbor-id hello- interval se conds area area -id virtual-link neighbor-id retransmit- interval second s area area -id virtual-link nei[...]
-
Page 17
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 15 Power Over Ethernet power inline usage-threshold <threshold> power inline usage-threshold <threshold> Power Over Ethernet priority { critical | high | low } p ower inline priorit y { critical | high | medium | low } Power Over Ethernet show powe r inline [det [...]
-
Page 18
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 16 SNMP snmp-serv er host {ip- address | hostname} comm unity {tr aps {v1 | v2} | infor ms [timeou t secon ds] [retri es ret ries]} [u dppor t port] [filter filtername] snmp-s erver hos t host-addr [i nforms [timeo ut seconds] [ retries ret ries] | trap s version {1 | 2 }]] [...]
-
Page 19
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 17 Time-B ased ACLs {deny | p ermi t} {every | {{icmp |i gmp| ipv6 | tcp | udp | number} { any | sourceipv6prefi x/prefixlength} [eq { portkey |por tvalue}] {a ny | destinatio nipv6prefix/prefixlength} [eq {portkey | portvalue}] [flow-label value] [dscp dsc p]}} [l og][assig[...]
-
Page 20
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 18 Deprecated Commands Feature Previous Implementati on Del l™ PowerConnect 4 .x Imple mentation 802.1x dot1x system- auth-control This command is changed to dot1x system- auth-control monitor. Address Table bridge address This command is ch anged to mac address - table st[...]
-
Page 21
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 19 Feature Previous Implementati on Dell™ PowerConnect 4.x Impl ementa tion Bridging bri dge address Interface Configuration mode Rationale: The followi ng parameters ha ve been deprecated: delete-on-reset delete-on-ti meout secure DHCP and BOOTP Rel ay bootpdhcprelay cidr[...]
-
Page 22
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 20 Feature Previous Implementati on Dell™ PowerConnect 4.x Impl ementa tion IPv6 Multicast ipv6 pimsm join- prune- interval This command is re placed by t he ipv6 pim j oin-prune- interval command. IPv6 Multicast ipv6 pimsm register- threshold This command is replaced by t[...]
-
Page 23
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 21 Feature Previous Implementati on Dell™ PowerConnect 4.x Impl ementa tion Multicas t ip pimsm spt-thres hold This command i s replaced by the ip pi m spt-threshold and ip pim register- rate-limit commands. Multicas t ip pimsm rp-a ddress This command is repla ced by the [...]
-
Page 24
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 22 Feature Previous Implementati on Dell™ PowerConnect 4.x Impl ementa tion Power Over Ethernet trapflags (i p ospf mode) This command is deprecated by the s nmp-server ena ble traps ospf command. Power Over Ethernet trapflags (i pv6 ospf mo de) This co mmand i s deprecate[...]
-
Page 25
Dell PowerC onnect™ Fi rmware CLI T ransitio n Guide April 6 , 2011 Page 23 Feature Previous Implementati on Dell™ PowerConnect 4.x Impl ementa tion System Management switch priorit y This command is deprecate d. Ref er to the System Management Commands section in the CLI REFERENCE GUIDE. Ip dvmrp trapflag s This command is deprecated by the sn[...]