Go to page of
Similar user manuals
-
Coffee maker
DeLonghi Magnifica ESAM3200
7 pages -
Espresso Machine
DeLonghi LATTISSIMA PRO EN 750.MB Nespresso
40 pages 9.51 mb -
Espresso Machine
DeLonghi Magnifica S ECAM22.110 B
21 pages 5.75 mb -
Kettle
DeLonghi KBOV 2001.AZ
5 pages -
Cooktop
DeLonghi D 61 E
36 pages 1.97 mb -
Coffeemaker
DeLonghi DC50T
42 pages 0.28 mb -
Blender
DeLonghi KF8110J
8 pages 0.19 mb -
Frozen Dessert Maker
DeLonghi ICK6000
6 pages 0.32 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of DeLonghi EUROCHEF - PRO, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of DeLonghi EUROCHEF - PRO one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of DeLonghi EUROCHEF - PRO. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of DeLonghi EUROCHEF - PRO should contain:
- informations concerning technical data of DeLonghi EUROCHEF - PRO
- name of the manufacturer and a year of construction of the DeLonghi EUROCHEF - PRO item
- rules of operation, control and maintenance of the DeLonghi EUROCHEF - PRO item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of DeLonghi EUROCHEF - PRO alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of DeLonghi EUROCHEF - PRO, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the DeLonghi service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of DeLonghi EUROCHEF - PRO.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the DeLonghi EUROCHEF - PRO item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
1 Air-2 EUROCHEF - PRO W ALL HOOD INST ALLA TION INSTR UCTIONS Shown with accessory Duct Cover Kit and accessory W arming Lamp Kit APPROVED FOR ALL RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONL Y PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING . INST ALLA TION MUST COMPL Y WITH ALL LOCAL CODES. IMPORT ANT : Save these Instructions for the Local [...]
-
Page 2
2 Air-2 EUROCHEF - PRO W ALL HOOD HOODS WEIGHT MODEL NUMBER 24” range hood with 600 CFM blower 22 lbs E C PH24S 30” range hood with 600 CFM blower 30 lbs E C PH30S 36” range hood with 600 CFM blower 36 lbs E C PH36S 48” range hood with 1200 CFM blower 48 lbs E C PH48S ACCESSORIES MODEL NUMBER WARMING LAMP KIT Includes 175W Warming Lamps, ro[...]
-
Page 3
3 Air-2 EUROCHEF - PRO W ALL HOOD CONSIDERA TIONS BEFORE INST ALLING HOOD 1 . For the most efficient air flow exhaust, use a straight run or as few elbows as possible. 2 . Do not use flex ducting use metal ductwork only to reduce the risk of fire. 3 . COLD WEA THER installations should have an additional backdraft damper installed to minimize backw[...]
-
Page 4
4 Air-2 EUROCHEF - PRO W ALL HOOD CONTENTS AND P AGE NUMBER Product Dimensions....................................................... pg.4 Advance Planning...........................................................pg.5 Using Duct Cover Accessories........................................ pg.5 T ools and Materials Required ...........................[...]
-
Page 5
5 Air-2 EUROCHEF - PRO W ALL HOOD Cabinetry and electrical placement for 24-inch deep wall hoods. lnstallatian dimensions for 24 deep wall hoods. ADV ANCE PLANNING USING DUCT COVER ACCESSORIES T o avoid gap s, plan the hood inst allation height for duct cover use. Recirculating Kit Cover 4” (if used) Duct cover 6” Duct cover 12” 1. Duct cover[...]
-
Page 6
6 Air-2 EUROCHEF - PRO W ALL HOOD REMOVE THE RANGEHOOD P AR TS PROVIDED Locate the parts packed with the hood. no. 4 screws to fix duct transition (torx 20) 3,9 x 9,5 mm no.3 screws and no.3 wall anchors (Philips) M5 x 57 mm Screws to hang and secure hood to the Wood Bracket (torx 20) 4,5 x 20 mm no. 4 for 24”-30” no. 6 for 36”-48” Parts In[...]
-
Page 7
7 Air-2 EUROCHEF - PRO W ALL HOOD STEP 1 DETERMINE HOOD, DUCTWORK AND WIRING LOCA TIONS • Use a level to draw the cooktop centerline vertically up the wall to the ceiling. • Measure desired distance from the bottom of the hood to the cooking surface, 24" min. to 36" max. Note: If installing with Duct Cover Kit or Recirculating Kit, se[...]
-
Page 8
8 Air-2 EUROCHEF - PRO W ALL HOOD model 30 36 model 48 two blowers V ertical Discharge (with Blower Upgrade Kit) BLOWER POSITION CHART model 24 V ertical Discharge BLOWER POSITION OPTION model 30 36 V ertical Discharge Hood size Motor Recirculating Kit option T op ducting option Rear ducting option 2 4 ” 1 YES YES YES 3 0 ” 1 YES YES YES 3 0 ?[...]
-
Page 9
9 Air-2 EUROCHEF - PRO W ALL HOOD IF CHANGING BLOWER POSITION WARNING: • disconnect the motor before changing position; reconnect after it is moved. A TTENTION: Débrancher le moteur avant de changer de position, rebrancher après le changement de position A “A” : remove bracket knock out before fixing 2 nd motor BLOWER UPGRADE KIT 30” AND [...]
-
Page 10
10 Air-2 EUROCHEF - PRO W ALL HOOD • Secure the Wood Bracket to 2 or more vertical studs, using at least 2 of the 4 supplied long screws. IMPORT ANT : Screws must penetrate at least 1-1/2" into verti- cal studs. Countersink screws into support. AFFIXING THE HOOD MOUNTING SCREWS IMPORT ANT : FRAMING MUST BE CAP ABLE OF SUPPORTING UP TO 150 LB[...]
-
Page 11
11 Air-2 EUROCHEF - PRO W ALL HOOD STEP 3B: AL TERNA TE MOUNTING METHOD INST ALL HOOD T O SOFFIT OR BENEA TH CABINETS SKIP THIS STEP IF USING W ALL MOUNTING METHOD When necessary , the hood may be installed so that it is supported by the soffit. • The soffit should be constructed with 2 x 4’s. • Determine the installation location on the wall[...]
-
Page 12
12 Air-2 EUROCHEF - PRO W ALL HOOD ASSEMBL Y AND INST ALLA TION OF THE DUCT COVERS & RECIRCULA TING KIT COVER Optional duct covers shown in advance planning section may be used to fill the space between the hood and ceiling in wall mount installations. 6" and 12" high duct covers are available and may be ordered separately . 1 . If mu[...]
-
Page 13
13 Air-2 EUROCHEF - PRO W ALL HOOD • Use screws removed in S tep 2 to re-install Filter Frame, per photograph. STEP 7: TIGHTEN - HANGING SCREWS STEP 8: RE-INST ALL THE FIL TER FRAME • With Filter Frame still removed from S tep 2 • Adjust hood up to eliminate any gaps at ceiling. Tighten hanging screws. • Add (2) more security screws + Washe[...]
-
Page 14
14 Air-2 EUROCHEF - PRO W ALL HOOD STEP 10: TEST FUNCTION OF HOOD - Blower - Light STEP 9: INST ALL FIL TER • Place filter drip trays into the bottom rear of the hood. • Insert top of grease filter first, than rotate bottom filter and drop into grease tray . • T o remove the filters, grasp the handle, push the filter up and lift out.[...]
-
Page 15
15 Air-2 EUROCHEF - PRO W ALL HOOD CARE AND USE REPLACING HALOGEN BULB OPERA TION Press any speed to turn hood on. Press same button to turn hood off. Active speed is shown by a button back light. CONTROL: 1. 1 Speed 2. 2 Speed 3. 3 Speed 4. 4 Speed Light DELA YED SHUTOFF By pressing down on any speed key for 2 seconds, while hood is running the 15[...]
-
Page 16
16 Air-2 EUROCHEF - PRO W ALL HOOD EUROCHEF U.S.A. 41 MERCEDES W A Y SUITE 25 EDGEWOOD NEW YORK 1 1717 – TEL. 866-844-6566 WWW .DELONGHIMAJORAPPLIANCES.COM WWW .DELONGHI RANGES.COM[...]