Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI should contain:
- informations concerning technical data of Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI
- name of the manufacturer and a year of construction of the Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI item
- rules of operation, control and maintenance of the Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Delta Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Delta Electronics Downstream Intelligent GE-PON ONU Transceiver OPEP-33-A4Q1RI item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 1 Revision: S3 12/20/2007 www .delt aww.c om 1.25Gbp s Up stream/1.25Gbp s Downstream Intelligent GE-PON ONU T ransceiver FEATURES z RoHS compliant z Digit a l Diagnostic SFF-8472 MSA compliant z Support extended operating Case temperatu re from -20 ºC to +85 ºC z IEEE802.3ah Gigabit Ethernet compliant z [...]

  • Page 2

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 2 Revision: S3 12/20/2007 www .delt aww.c om 1. Absolute Maximum Ratings Parameter Symbol Min. Ty p . Max. Unit Note S torage T emperature T s -40 85 ºC S torage Ambient Humidity H A 5 95 % Power Supply V oltage V CC -0.3 4 V Signal Input V oltage -0.3 Vcc+0.3 V Receiver Damage Threshold +2 dBm Lead Solder[...]

  • Page 3

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 3 Revision: S3 12/20/2007 www .delt aww.c om Note (4). Transmitter spectral limits Note (5). Tr ansmitter eye mask definition 4. Specification of Receiver Parameter Symbol Min. Ty p . Max. Unit Note Input Op tical Wavelength λ IN 1480 1490 1500 nm PIN-PD Receiver Sensitivity P IN -26 dBm Note (1) Input Sat[...]

  • Page 4

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 4 Revision: S3 12/20/2007 www .delt aww.c om Note (1). Measure d with Light source +1dBm, 1490 nm, ER=9dB; BER =<10 -12 @PRBS=2 7 -1 NRZ This assuranc e should be m et with asy nchronous dat a flow ing out of the optical transmitter of the system under test. Th e output data pattern from the transmitter [...]

  • Page 5

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 5 Revision: S3 12/20/2007 www .delt aww.c om 6. T ransmitter Burst Mode Timing Characteristics Parameter Symbol Min. Ty p . Max. Unit No te BiasCNT Enable Duration 1 us Interval of BiasCNT Signal 0.1 12 1000000 us VccT BiasCNT Data Input Optica l Output VccT < 3.1 V X X OFF Low X OFF Floating Other VccT [...]

  • Page 6

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 6 Revision: S3 12/20/2007 www .delt aww.c om 8. Pin Description Tx/Rx Pin No. I/O Pin Name Description 1 V eeR Receiver Ground 2 VccR +3.3V Receiver Power Supply 3 O SD Normal Optical Input indicated by logic “High”, and No Optical Input indicated by logic “Low”. 4 O RD(n) Inverted Receiver Data Out[...]

  • Page 7

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 7 Revision: S3 12/20/2007 www .delt aww.c om 9. Recommended Interface Circuit T rans m itter 9. TD ( p) 10. TD(n) 8. Bia sCNT 6. VccT 7. VeeT Receiver 100nF 100nF 2. VccR 5. RD ( p) 4. RD(n) 3. SD 1. VeeR 100nF 10uF 100nF 10uF 100nF 1uH 1uH 3.3V Protocol IC Ser Des IC 100ohm Bi as CNT SD DELTA GEPON ONU Mod[...]

  • Page 8

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 8 Revision: S3 12/20/2007 www .delt aww.c om 10. Outline Di mensions Parameter Unit Desc ripti on Note Mechanica l Dimens ions mm 48.3x13. 5x9.6 Connector T ype - SC/UPC connecto r IEC-61754-4 W eek (52W eeks/Y ear) : 1月 2日 =01[...]

  • Page 9

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 9 Revision: S3 12/20/2007 www .delt aww.c om 1 1. Enhanced Digital Diagnostic Interface The memory map in the follow ing describes an extension to the memory map defined in SFF-8472. The enhanced interface uses the two wire ser ial bus address 1010001X(A2h) to provide diagnostic information about the module[...]

  • Page 10

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 10 Revis ion: S3 12/20/2007 www .delt aww.c om EEPROM Serial ID Memory Content s (2-Wire Address A0h) Addres s Name of Fiel d Hex Desc ripti on Base ID Fields 00 Identifier 80 V endor specific 01 Ext. Identifier 04 Serial ID module supported 02 Connect o r 01 SC connecto r 03-10 Transceiver Codes 00 00 00 8[...]

  • Page 11

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 11 R e v i s i o n : S 3 12/20/2007 www .delt aww.c om Digit al Diagnostic Monitoring Interface (2-Wire Address A2h) Alarm and W arnin g Thresholds (2 Wire Address A 2h) Addre ss # Bytes Name of Field HEX Real V alue Unit 00-01 2 T emp High Alarm 64 00 100 ℃ ºC 02-03 2 T emp Low Alarm DD 00 -35 ℃ ºC 0[...]

  • Page 12

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 12 Revis ion: S3 12/20/2007 www .delt aww.c om A/D V a lue (2 Wire Address A2h) Addres s # Byte s Name of Field Desc ripti on 96-97 2 T emperature ( MSB, LSB) Internally measured module temp erature 98-99 2 Supply V oltage (MSB, LSB) Internally measured supply voltage in module 100-101 2 Tx Bias Current (MS[...]

  • Page 13

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 13 Revis ion: S3 12/20/2007 www .delt aww.c om St atus Bits and Alarm/Warning Flag Bit s (2 Wire Address A2h) Address Bit Name Descri ption 1 10 7 TX Disable S tate No implemented. 1 10 6 Soft TX Disable No implemented. 1 10 5 Reserved 1 10 4 RX Rate Select S tate No implemented. 1 10 3 Soft RX Rate Select [...]

  • Page 14

    OPEP-33-A4Q1RI DEL T A ELECT RONICS, INC. 14 Revis ion: S3 12/20/2007 www .delt aww.c om 12. R egulat ory C ompl iance Feature Te s t M e t h o d Reference Performance Human Body Model (HBM) MIL-STD-883E Method 3015.7 EIA-JESD22-A1 1 4 Elect rosta tic Disc harge (ESD) to the Electrical Pins Machine Model (MM) EIA-JESD22-A1 15 Contact Discharge IEC/[...]