Delta Electronics E48SR12007 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Delta Electronics E48SR12007, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Delta Electronics E48SR12007 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Delta Electronics E48SR12007. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Delta Electronics E48SR12007 should contain:
- informations concerning technical data of Delta Electronics E48SR12007
- name of the manufacturer and a year of construction of the Delta Electronics E48SR12007 item
- rules of operation, control and maintenance of the Delta Electronics E48SR12007 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Delta Electronics E48SR12007 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Delta Electronics E48SR12007, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Delta Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Delta Electronics E48SR12007.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Delta Electronics E48SR12007 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    DATASHEET DS_E48SR12007_05 222008 FEATURES  High efficiency: 92.0% @ 12V/7A  Size: 58.4mmx22.80mmx8.4mm (2.30”x0.90”x0.33”)  S tandard footprint  Industry standard pin out  2:1 Input voltage range  Fixed frequency operation  Input UVLO, Output OCP , OVP , OTP  2250V isolation and basic insulation  No minimum load re[...]

  • Page 2

    E48SR12007_0522200 8 2 TECHNICAL SPECIFICA TIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal V out u nless otherwise no ted.) PA R A M E T E R NOTES and CONDITIONS E48SR12007 (St andard) Min. T y p. Max. Un its ABSOLUTE MAXIMUM RA TINGS Input V oltage Continuous 80 Vdc T ransient (100ms) 100ms 100 Vdc Operating T emperature Refer to Fig[...]

  • Page 3

    E48SR12007_0522200 8 3 ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Efficiency vs. load current for minimum, nominal, and maximum input voltage at 25°C, 300LFM airflow. Figure 2: Power dissipation vs. load current for mini mum, nominal, and max imum input voltage at 25°C, 300LFM airflow . Figure 3: T ypical full l oad input characteristic s at 25[...]

  • Page 4

    E48SR12007_0522200 8 4 ELECTRICAL CHARACTERISTICS CUR VES For Negative Remote On/Off Logic Figure 4: T urn-on transient at full ra ted load current (resi stor load) (2ms/div). Vin=48V . T op T race: V out, 5V/div; Bo ttom T race: ON/OFF input, 5V/div Figure 5: T urn-on tra nsient at zero load current (2ms/div). Vin=48V . T op T race: V out, 5V/div;[...]

  • Page 5

    E48SR12007_0522200 8 5 ELECTRICAL CHARACTERISTICS CUR VES Figure 8: Output voltage response to step-change in load current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF t a ntalum capacitor and 1µF ceramic capacitor . T op T race: V out (0.2V/div , 200us/div), Bottom T race: Iout (1 A /div). Scope measurement should be made usi ng a [...]

  • Page 6

    E48SR12007_0522200 8 6 ELECTRICAL CHARACTERISTICS CUR VES Figure 12: Input reflected ripple current, i s , through a 12µH source inductor at nominal input voltage an d rated load current (20 mA/div , 2us/div) Figure 13: Output voltage noise and ripple measurement test setup 0 2 4 6 8 10 12 14 01 2 3 45 6 78 9 1 0 L O AD CURRE NT (A ) OUTPUT VOLTAG[...]

  • Page 7

    E48SR12007_0522200 8 7 DESIGN CONSIDERA TIONS Input Source Impedance The impedance of the input source connecting to the DC/DC power module s will interact with the modules and affect the st ability . A low ac-impedance input source is recommended. If the source induct ance is more than a few μ H, we advise adding a 10 to 100 μ F electrolytic cap[...]

  • Page 8

    E48SR12007_0522200 8 8 FEA TURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-current protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modul es will automatically shut down (hiccup mode). The modules will [...]

  • Page 9

    E48SR12007_0522200 8 9 FEA TURES DESCRIPTIONS (CON.) Output V oltage Adjustment (TRIM) To increase or decrease t he output voltage set point, the modules may be conne cted with an external resisto r between the TRIM pin and either the SENSE(+) or SENSE(-). The TRIM pin should be left open if this feature is not used. Figure 18: Circuit configuratio[...]

  • Page 10

    E48SR12007_0522200 8 10 THERMAL CONSIDERA TIONS Thermal management is an importa nt part of the system design. To ensure prop er, reliable operation, suffici ent cooling of the power mod ule is needed over the entire temperature range of the modul e. Convection coolin g is usually the dominant mode of heat transfer. Hence, the choice of equipment t[...]

  • Page 11

    E48SR12007_0522200 8 11 P I C K A N D P L A C E L O C A T I O N S U R F A C E - MOUNT T APE & REEL RECOMMENDED P AD LA YOUT (SMD)[...]

  • Page 12

    E48SR12007_0522200 8 12 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP . PROFILE T ime ( sec. ) Pre-h eat tem p. 140~180 ° C 60~120 sec. Peak tem p. 210~230 ° C 5sec . Ramp-up te mp. 0.5~3.0 ° C /sec . T emperature ( ° C ) 50 100 150 200 250 300 60 0 120 180 240 2nd Ramp-up temp. 1.0~3.0 ° C /sec. Over 200 ° C 40~50sec. Cooling down rate < 3 ° C /[...]

  • Page 13

    E48SR12007_0522200 8 13 MECHANICAL DRA WING (WIT HOUT HEA TSPREADER) Surface-mount module Through-hole module Pin No. Name Function 1 2 3 4 5 6 7 8 +Vin ON/OFF -Vin -V out -SENSE TRIM +SENSE +V out Positive input voltage Remote ON/OFF Negative input voltage Negative output voltage Negative remote sense Output voltage trim Positive remote sense Posi[...]

  • Page 14

    E48SR12007_0522200 8 14 MECHANICAL DRA WING (WITH HEA TSPREADER) THROUGH-HOLE MODULE[...]

  • Page 15

    E48SR12007_0522200 8 15 P ART NUMBERING SYSTEM E 48 S R 120 07 N R F A T ype of Product Input V olt age Number of Output s Product Series Output V olt age Output Current ON/OFF Logic Pin Length Option Code E- Eighth Brick 48V S- Single R- Regular 120-12V 07- 7A N- Negative (Default) P- Positive R - 0.170” (Default) N - 0.145” K - 0.1 10” M - [...]