Delta Electronics IPM24S0B0 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Delta Electronics IPM24S0B0, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Delta Electronics IPM24S0B0 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Delta Electronics IPM24S0B0. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Delta Electronics IPM24S0B0 should contain:
- informations concerning technical data of Delta Electronics IPM24S0B0
- name of the manufacturer and a year of construction of the Delta Electronics IPM24S0B0 item
- rules of operation, control and maintenance of the Delta Electronics IPM24S0B0 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Delta Electronics IPM24S0B0 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Delta Electronics IPM24S0B0, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Delta Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Delta Electronics IPM24S0B0.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Delta Electronics IPM24S0B0 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Delphi Series IPM24S0B0, Non-Isolated, Integrated Point-of-Load Power Modules: 1 1V~36V input, 3.3~6.5V and 3A Output The Delphi Series IPM24S0B0 non-isolated, fully integrated Point-of-Load (POL) power module s, are the latest offerings from a world leader in power sy stems technology and manufa cturing -- Delta Electronics, Inc. This pro duct fam[...]

  • Page 2

    DS_IPM24S0B0_03202007 2 TECHNICAL SPECIFICA TIONS T A = 25°C, airflow rate = 300 LFM, V in = 24Vdc, nominal V out unless otherwise noted. P ARAMETER NOTES and CONDITIONS IPM24S0B0R/S03F A Min. T yp. Max. Units ABSOLUTE MAXIMUM RA TINGS Input V olt age (Continuous) 0 40 Vdc Operating T emperature Please refer to Fig. 32 for the measuring poin t -40[...]

  • Page 3

    DS_IPM24S0B0_03202007 3 ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Converter efficiency vs. output current (3.30V output voltage) Figure 2: Converter efficiency vs. output current (4.0V output voltage) Figure 3: Converter efficiency vs. output current (5.0V output voltage) Figure 4: Converter efficiency vs. output current (6.5V output voltage) Fi[...]

  • Page 4

    DS_IPM24S0B0_03202007 4 ELECTRICAL CHARACTERISTICS CUR VES Figure 7: Output ripple & noise at 12Vin, 4.0V/3A out Figure 8: Output ripple & noise at 24Vin, 4.0V/3A out Figure 9: Output ripple & noise at 12V in, 5.0V/3A out Figure 10: Output ripple & noise at 24Vin, 5.0V/3A o ut Figure 1 1: Output ripple & noise at 12Vin, 6.5V/3A [...]

  • Page 5

    DS_IPM24S0B0_03202007 5 ELECTRICAL CHARACTERISTICS CUR VES Figure 13: Power on waveform at 12vin, 3.3V/3A out with application of Vin Figure 14: Power on waveform at 12vin, 6.5V/3A out with application of Vin Figure 15: Power of f waveform at 12vin, 3.3V/3A out with application of Vin Figure 16: Power of f waveform 12v in,6.5V/3A out with applicati[...]

  • Page 6

    DS_IPM24S0B0_03202007 6 ELECTRICAL CHARACTERISTICS CUR VES Figure 19: T urn on delay at 24vin, 3.3V/3A out with application of Vin Figure 20: T urn on delay at 24vin, 6.5V/3A out with application of Vin Figure 21: T ypical transient response to step loa d change at 0.5A/µS from 100% to 50% of Io, max at 12Vin, 6.5V out (measurement with a 1uF cera[...]

  • Page 7

    DS_IPM24S0 7 B0_03202007 TEST CONFIGURA TIONS V I (+) V I (-) BAT TERY 2 100uF Electr oly tic L TO O SC ILLOS CO PE Cera mi c 3.3uF Note: Input reflected-ripple current is measured with a simulated source induct ance. Current is measured at the input of the module. Figure 23: Input reflected-ripple current test setup Vo GND COPP ER STRI P 220uF Pos[...]

  • Page 8

    DS_IPM24S0B0_03202007 8 DESIGN CONSIDERA TIONS Remote On/Off The IPM series powe r modules have an On/Of f control pin for output volt age remote On/Of f operation. The On/Off pin is an open coll ector/drain logic input sign al that is referenced to grou nd. When On/Of f control pin is not used, leave the pin unconne cted. The remote on/of f pin is[...]

  • Page 9

    DS_IPM24S0B0_03202007 9 FEA TURES DESCRIPTIONS (CON.) Figure 28: T rim up Circuit configuration for programming output voltage using an external resistor Rtrim Lo ad Vout Tri m GND Figure 29: T rim down Circuit configuration for programming output voltage using an external resistor Figure 30: Circuit configuration for programming output vol tage us[...]

  • Page 10

    DS_IPM24S0B0_03202007 10 THERMAL CONSIDERA TIONS Thermal management is an importa nt part of the system design. To ensure prop er, reliable operation, suffici ent cooling of the power mod ule is needed over the entire temperature range of the modul e. Convection coolin g is usually the dominant mode of heat transfer. Hence, the choice of equipment [...]

  • Page 11

    DS_IPM24S0B0_03202007 11 IPM24S (Standard) Output Current vs. Ambient Temperature and Air Velocity @ Vin=24V, Vout = 6.5V (Either Orientati on) 0 1 2 3 60 65 70 75 80 85 Ambient Temperature ( ℃ ) Output Current(A) Natural Convection 100LFM 200LFM Figure 33: Output current vs. ambient temperature and air velocity @Vin=24V , V out=6.5V(Either Orien[...]

  • Page 12

    DS_IPM24S0B0_03202007 12 PICK AND PLACE LOCA TION A ll dimensions are in millimeter s (inches) SURF ACE- MOUNT T APE & REEL A ll dimensions are in millimete r s (inches) LEAD FREE PROCESS RECO MMEND TEMP . PROFILE Te Tim e 60 ~ 15 0 sec. Abo ve 2 17 0 C 20 ~ 40s ec. R a m p u p m ax. 3.0 0 C/ sec Preheat time 60 ~ 180 sec. Ram p down m ax. 6.0 [...]

  • Page 13

    DS_IPM24S0B0_03202007 13 Mechanical Drawing SMD P ACKAGE SIP P ACKAGE RECOMM END PWB PAD L AYOUT RECOMMEND PWB HO LE LAYOUT 12 3 45 12 3 4 5 76 12 3 45 : The copper pad is re commended to connec ote: All dimension are in millimeters (inches) standa rd dimension tolerance is ± 0.10(0.004”) Note t to the ground. N[...]

  • Page 14

    DS_IPM24S0B0_03202007 14 P ART NUMBERING SYSTEM IPM 24 S 0B0 S 03 F A Product Family Input V oltage Number of Output s Output V olt age Package Output Current Option Code Integrated POL Module 1 1V ~ 36V S - Single 0B0 - programmable output 3.3V~6.5V R - SIP S - SMD 03 - 3A F- RoHS 6/6 (Lead Free) A - S tandard Function MODEL LIST Model Name Input [...]