The rules should oblige the seller to give the purchaser an operating instrucion of Delta Electronics Series S48SP, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Delta Electronics Series S48SP one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Delta Electronics Series S48SP. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Delta Electronics Series S48SP should contain:
- informations concerning technical data of Delta Electronics Series S48SP
- name of the manufacturer and a year of construction of the Delta Electronics Series S48SP item
- rules of operation, control and maintenance of the Delta Electronics Series S48SP item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Delta Electronics Series S48SP alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Delta Electronics Series S48SP, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Delta Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Delta Electronics Series S48SP.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Delta Electronics Series S48SP item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Delphi Series S48SP , 35W 1x1 Brick DC/DC Power Modules: 48V in, 3.3V/10A out The Delphi Series S48SP , 1x1 Brick, 48V input, single output, isolated DC/DC converters a re the latest of fering from a world leader in p ower systems technology and manufacturi ng ― Delt a Electronics, Inc. This product family is available in a surface mount or throu[...]

  • Page 2

    DS_S48SP3R310_05222008 2 TECHNICAL SPECIFICA TIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal V ou t unless otherwise no ted.) PA R A M E T E R NOTES and CONDITIONS S48SP3R310 (St andard) Min. T yp . Max. Unit s ABSOLUTE MAXIMUM RA TINGS Input V oltage Continuous 80 Vdc T ransient (100ms) 100ms 100 Vdc Operating T emperature Refer to F[...]

  • Page 3

    DS_S48SP3R310_05222008 3 ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Ef ficiency vs. load current for minimum, nominal, and maximum in put voltage at 25°C Figure 2: Power dissipation vs. load current for min imum, nominal, and max imum input voltage at 25°C. Figure 3: T ypical full load input charac teristics at room temperature[...]

  • Page 4

    DS_S48SP3R310_05222008 4 ELECTRICAL CHARACTERISTICS CUR VES For Negative Remote On/Off Logic Figure 4: T urn-on transient at full rated loa d current (5 ms/div ). Vin=48V . T op T race: V out, 1. 0V/div; Bottom T race: ON/OFF input, 2V/div Figure 5: T urn-on transient at zero load current (5 ms/div). Vin=48V . T op T race: V out, 1 .0V/div , Bottom[...]

  • Page 5

    DS_S48SP3R310_05222008 5 ELECTRICAL CHARACTERISTICS CUR VES Figure 8: Output voltage response to step-change in load current (75%-50% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF tantalum cap acitor and 1 µF ceramic capacitor . T op T race: Vout (100mV/div , 50us/div ) , Bottom T race: Iout (2A/div). Scope measurement should be made usi ng a BNC[...]

  • Page 6

    DS_S48SP3R310_05222008 6 ELECTRICAL CHARACTERISTICS CUR VES Figure 12: Input reflected ripple current, i s , through a 12µH source inductor at nominal input voltage an d rated load current (20 mA/div , 1us/div) Figure 13: Output voltage noise and ripple measur ement test setup Figure 14: Output voltage ripple at nominal input voltage and rated loa[...]

  • Page 7

    DS_S48SP3R310_05222008 7  The input source must be insulated from the ac mains by reinforced or double insulation.  The input terminals of the module are not operator accessible.  If the metal baseplate is grounded , one Vi pin and one Vo pin shall also be grounded.  A SELV reliability test is conducted on the system where the module is[...]

  • Page 8

    DS_S48SP3R310_05222008 8 FEA TURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-curre nt protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modul es will automatically shut dow n, and enter hiccup mode or la[...]

  • Page 9

    DS_S48SP3R310_05222008 9 FEA TURES DESCRIPTIONS (CON.) Output V oltage Adjustment To increase or decrea se the output voltage set poi nt, the modules may be connected wit h an external resistor between the TRIM pin and either the Vo (+) or Vo(-). The TRIM pin should be left open if this feature is not used. R Load Vo (+) Trim Vo (-) R trim-down Vi [...]

  • Page 10

    DS_S48SP3R310_05222008 10 THERMAL CONSIDERA TIONS Thermal management is an importa nt part of the system design. To ensure prop er, reliable operation, suffici ent cooling of the power mod ule is needed over the entire temperature range of the modul e. Convection coolin g is usually the dominant mode of heat transfer. Hence, the choice of equipment[...]

  • Page 11

    DS_S48SP3R310_05222008 11 PICK AND PLACE LOCA TION SURF ACE-MOUNT T APE & REEL RECOMMENDED P AD LA YOUT (SMD)[...]

  • Page 12

    DS_S48SP3R310_05222008 12 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP . PROFILE T i me ( sec. ) Pre-h eat tem p. 140~180 ° C 60~120 sec. Peak tem p. 210~230 ° C 5sec . Ramp-up te mp. 0.5~3.0 ° C /sec . T emperature ( ° C ) 50 100 150 200 250 300 60 0 120 180 240 2nd Ramp-up temp. 1.0~3.0 ° C /sec. Over 200 ° C 40~50sec. Cooling down rate < 3 ° [...]

  • Page 13

    DS_S48SP3R310_05222008 13 MECHANICAL DRA WING Surface-mount module Through-Hole module Pin No. Name Function 1 2 3 4 5 6 +Vin -Vin ON/OFF (Optional) -V out TRIM (Optional) +V out Positive input voltage Negative input voltage Remote ON/OFF (Optional) Negative output voltage Output voltage trim (Optional) Positive output voltage[...]

  • Page 14

    DS_S48SP3R310_05222008 14 P ART NUMBERING SYSTEM S 48 S P 3R3 10 N R F B Product Ty p e Input V olt age Number of Output s Product Series Output Vo l t a g e Output Current ON/OFF Logic Pin Length/T ype Option Co de S - Small Power 48- 36V~75V S - Single 1x1, 10A 3R3 - 3.3V 10 - 10A N - Negative (Default) P - Positive E- No remote on/off control fu[...]