A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Desa B50G, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa B50G one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Desa B50G. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Desa B50G should contain:
- informations concerning technical data of Desa B50G
- name of the manufacturer and a year of construction of the Desa B50G item
- rules of operation, control and maintenance of the Desa B50G item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa B50G alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa B50G, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa B50G.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa B50G item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
PORT ABLE FORCED AIR HEA TERS OWNER’S MANUAL IMPORTANT Read and understand this manual before assembling, starting, or servic- ing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. Heater Models: B50G and REM50B ARL LOGO G 004 ®[...]
-
Page 2
2 102016 Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Unpacking ..................................................................................... 4 Theory of Operation .................................[...]
-
Page 3
3 102016 SAFETY INFORMA TION Continued W ARNINGS (Continued) • Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels. • Fueling a) Personnel involved with fueling shall be qualified and thoroughly familiar with the manufacturer's instr[...]
-
Page 4
4 102016 PRODUCT IDENTIFICA TION 35/50/70,000 BTU/HR DOMESTIC PFA/PV 042 Handle Fuel Cap Lower Shell Power Cord Side Cover Fuel Tank Hot Air Outlet Air Filter End Cover Fan Guard Upper Shell Flame-Out Control Reset Button Figure 1 - Models B50G and REM50B 1. Remove all packing items applied to heater for shipment. 2. Remove all items from carton. 3[...]
-
Page 5
5 102016 W ARNING ! FUELS Do not use heavy fuels such as No. 2 fuel oil or No. 2 Diesel. Using heavy fuels will result in: • clogged fuel fi lter and nozzle • carbon build up on spark plug • the need of non-toxic anti-icer in fuel during very cold weather IMPORTANT: Use a KEROSENE ONLY storage container. Be sure storage container is clean. F[...]
-
Page 6
6 102016 OPERA TION W ARNING ! Review and understand the warnings in the Safety Information Section, pages 2 and 3. They are needed to safely operate this heater. Follow all local codes when using this heater. To Start Heater 1. Follow all ventilation and safety information. 2. Fill fuel tank with kerosene or No. 1 fuel oil. 3. Attach fuel cap. 4. [...]
-
Page 7
7 102016 ST ORING, TRANSPORTING, OR SHIPPING Note: If shipping, transport companies require fuel tanks to be empty. 1. Drain fuel tank. Note: Some models have drain plug on underside of fuel tank. If so, remove drain plug to drain all fuel. If heater does not have drain plug, drain fuel through fuel cap opening. Be sure all fuel is removed. 2. Repl[...]
-
Page 8
8 102016 Wrong pump pressure Dirty air output, air intake and lint fi lters Dirty fuel fi lter Dirt in nozzle Dirty or bad photocell lens Bad flame-out control Heater ignites, but flame-out control shuts off heater after a short period of time. W ARNING ! TROUBLE- SHOOTING Never service heater while it is plugged in, operating, or hot. Severe bur[...]
-
Page 9
9 102016 SER VICE PROCEDURES W ARNING ! Upper Shell Removal 1. Remove screws along each side of heater using 5/16" nut-driver. These screws attach upper and lower shells together. 2. Lift upper shell off. 3. Remove fan guard. Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. Air Output[...]
-
Page 10
10 102016 Relief Valve Pressure Gauge Plug Continued Pump Pressure Adjustment 1. Remove pressure gauge plug from fi lter end cover. 2. Install accessory pressure gauge (part number HA1180). 3. Start heater (see Operation, page 6). Allow motor to reach full speed. 4. Adjust pressure. Turn relief valve to right to increase pressure. Turn relief valv[...]
-
Page 11
11 102016 50 ROTOR PFA/P 056 Fuel Line Hose Nozzle Assembly Figure 13 - Removing Air and Fuel Line Hoses Combustion Chamber Air Line Hose Nozzle Assembly Figure 14 - Removing Nozzle Assembly Burner Strap Nozzle Nozzle Face Nozzle Adapter Air Line Fitting Fuel Line Fitting Nozzle Seal Figure 16 - Rotor Location Pump Plate Blade Air Intake Filter Fil[...]
-
Page 12
12 102016 Blade Rotor .003"/.004" Gap Measured With Feeler Gauge Gap Adjusting Screw Sandpaper Gap Adjusting Screw Figure 18 - Sanding Rotor Figure 17 - Gap Adjusting Screw Locations (Pump Rotor, continued) 10. Install blades, pump plate, air fi lters, and fi lter end cover. 11. Replace fan guard and upper shell. 1 2 . Adjust pump press[...]
-
Page 13
13 102016 Note: Use only original replacement parts. This will protect your warranty cover- age for parts replaced under warranty. Parts Under Warranty Contact authorized dealers of this product. If they can ’ t supply original replacement part(s), call DESA International ’ s Technical Service Dept. at 1-800-323-5190. When calling DESA Internat[...]
-
Page 14
14 102016 ILLUSTRA TED P ARTS BREAKDOWN PFA/P 003 MOTOR & PUMP 30 EAI/EBI 12-1 12-2 12-3 12-4 12-5 12-6 12-7 12-8 12-9 12-10 12-11 12-13 12-18 12-17 12-16 12-15 12-14 12-12 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 9-1 9-2 9-3 9-4 9-5 17 19 21 22 23 24 25 26 27 30 31 32 33 36 37 38 39 28 29 34 35 40 16 18 20[...]
-
Page 15
15 102016 This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. P ARTS LIST Models B50G and REM50B KEY PART NO. NUMBER DESCRIPTION QTY. KEY PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Ha[...]
-
Page 16
W ARRANTY AND REP AIR SERVICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workman- ship. If so, DESA International will repair or replace the heater without ch[...]