Go to page of
Similar user manuals
-
Electric Heater
Desa CGD3930PT
44 pages 5.25 mb -
Electric Heater
Desa VN1800C
40 pages 0.63 mb -
Electric Heater
Desa GWP30TA
28 pages 1.66 mb -
Electric Heater
Desa VMH3000TNA
24 pages 0.76 mb -
Electric Heater
Desa RCLP50VA
28 pages 0.47 mb -
Electric Heater
Desa CP600AK
20 pages 2.19 mb -
Electric Heater
Desa BLP375AT
14 pages 0.88 mb -
Electric Heater
Desa BLP30
14 pages 0.29 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Desa B70D, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa B70D one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Desa B70D. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Desa B70D should contain:
- informations concerning technical data of Desa B70D
- name of the manufacturer and a year of construction of the Desa B70D item
- rules of operation, control and maintenance of the Desa B70D item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa B70D alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa B70D, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa B70D.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa B70D item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
POR T ABLE FORCED AIR HEA TER OWNER’S MANUAL IMPORTANT: Read and understand this manual before assembling, starting, or servicing heater. Improper use of heater can cause serious injury. Keep this manual for future reference. ARL LOGO G 004 ® Heater Size: 70,000 Btu/Hr Models: R70D and B70D H.S.I. Series[...]
-
Page 2
2 103685 POR T ABLE FORCED AIR HEA TERS 70,000 Btu/Hr H.S.I. Series SAFETY INFORMA TION WARNINGS IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, oper- ate, or service this heater. Im- proper use of this heater can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monox[...]
-
Page 3
3 103685 OWNER’S MANUAL Figure 2 - Cross Section Operational View Clean Heated Air Out Figure 1 - 70,000 Btu/Hr Handle Fuel Cap Lower Shell Power Cord Fuel Tank Hot Air Outlet Air Filter End Cover Fan Guard Upper Shell Side Cover Ignition Control Assembly (assembly on inside of side cover) UNP ACKING 1. Remove all packing items applied to heater [...]
-
Page 4
4 103685 POR T ABLE FORCED AIR HEA TERS 70,000 Btu/Hr H.S.I. Series TO START HEATER 1. Follo w all v entilation and safety infor- mation. 2. Fill fuel tank with kerosene or No. 1 fuel oil. 3. Attach fuel cap. 4. Plug power cord of heater into three- prong, grounded extension cord. Exten- sion cord must be at least six feet long. Extension Cord Wire[...]
-
Page 5
5 103685 OWNER’S MANUAL STORING, TRANSPOR TING, OR SHIPPING Note: If shipping, transport companies re- quire fuel tanks to be empty. 1. Drain fuel tank. Drain fuel through fuel cap opening. Be sure all fuel is re- moved. 2. If any debris is noted in old fuel, add 1 or 2 quarts of clean kerosene to tank, stir , and drain again. This will prev ent [...]
-
Page 6
6 103685 POR T ABLE FORCED AIR HEA TERS 70,000 Btu/Hr H.S.I. Series TROUBLESHOOTING WARNING: Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur. REMEDY 1. Check circuit breaker in electrical panel 2. Check all electrical connections. See W iring Diag ram, page 11 3. See Ignition Contr ol Asse[...]
-
Page 7
7 103685 OWNER’S MANUAL Figure 3 - Upper Shell Removal SER VICE PROCEDURES WARNING: Never service heater while it is plugged in, op- erating, or hot. Severe burns and electrical shock can occur. UPPER SHELL REMOVAL 1 . Remove screws along each side of heater using 5/16" nut-dri ver . These screws attach upper and lower shells together . 2. L[...]
-
Page 8
8 103685 POR T ABLE FORCED AIR HEA TERS 70,000 Btu/Hr H.S.I. Series SER VICE PROCEDURES Continued WARNING: Never service heater while it is plugged in, op- erating, or hot. Severe burns and electrical shock can occur. Fuel Filter Side Cover Upper Fuel Line Figure 8 - Fuel Filter Removal FUEL FILTER 1 . Remove 4 side cover screws using 5/16" nu[...]
-
Page 9
9 103685 OWNER’S MANUAL SER VICE PROCEDURES Continued Figure 12 - Removing Air and Fuel Line Hoses NOZZLE ASSEMBLY 1. Remov e upper shell (see page 7). 2. Remov e fan (see page 7). 3. Remov e fuel and air line hoses from nozzle assembly (see Figure 12). 4. T urn nozzle assembly 1/4 turn to left and pull toward motor to remove (see Figure 13). 5. [...]
-
Page 10
10 103685 POR T ABLE FORCED AIR HEA TERS 70,000 Btu/Hr H.S.I. Series SER VICE PROCEDURES Continued PUMP ROTOR (Procedure if Rotor is Binding) 1. Remov e upper shell (see page 7). 2. Remov e filter end cover scre ws using 5/16" nut-dri ver . 3. Remove filter end cover and air filters. 4. Remove pump plate screws using 5/16" nut-dri ver [...]
-
Page 11
11 103685 OWNER’S MANUAL SPECIFICA TIONS Output Rating (Btu/Hr) 70,000 Fuel Use Only Kerosene or No. 1 Fuel Oil Fuel Tank Capacity (U.S. Gal.) 5.0 Fuel Consumption (Gal. Per Hr.) .52 Electric Requirements 120 V/60 Hz Amperage (Normal Run) 2.8 Hot Air Output (CFM) 360 Motor RPM 3440 Motor HP 1/8 Shipping Weight (Approximate Pounds) 36 Heater Weigh[...]
-
Page 12
12 103685 POR T ABLE FORCED AIR HEA TERS 70,000 Btu/Hr H.S.I. Series ILLUSTRA TED PA R T S BREAKDOWN Motor and Pump Assembly 12-11 12-18 12-17 12-16 12-15 12-14 12-13 12-12 12-10 12-1 12-2 12-3 12-4 12-5 12-6 12-7 12-8 12-9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 9-2 9-1 9-3 9-4 9-5 17 18 19 20 21 22 23 24 25 26 27 28 29 30 34 35 36 32 33 31 R70D B7[...]
-
Page 13
13 103685 OWNER’S MANUAL P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, be sure to provide the correct model and serial numbers (from the model plate), then the part number and description of the desired part. KEY PART NO. NUMBER DESCRIPTION QTY. 1 M51104-01 Handle 1 2 098511-36 Upper Shell (R70D) 1 098[...]
-
Page 14
W ARRANTY AND REP AIR SERVICE WARRANTY SERVICE Should your heater require service, return it to your nearest authorized service center. Proof of purchase must be presented with the heater. The heater will be inspected. A defect may be caused by faulty materials or workmanship. If so, DESA International will repair or replace the heater without char[...]