The rules should oblige the seller to give the purchaser an operating instrucion of Desa CGP16RA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa CGP16RA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Desa CGP16RA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Desa CGP16RA should contain:
- informations concerning technical data of Desa CGP16RA
- name of the manufacturer and a year of construction of the Desa CGP16RA item
- rules of operation, control and maintenance of the Desa CGP16RA item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa CGP16RA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa CGP16RA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa CGP16RA.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa CGP16RA item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Save this manual for future reference. OWNER’S OPERA TION AND INST ALLA TION MANUAL VENT -FREE INF ARED PROP ANE/LP GAS HEA TER Models: CGP16RA and CGP26D WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or[...]

  • Page 2

    2 101827 CONTENTS SECTION PAGE Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Local Codes ................................................................................... 4 Unpacking ......................[...]

  • Page 3

    3 101827 SAFETY INFORMA TION Continued W ARNINGS Continued WARNING: Any change to this heater or its controls can be dangerous. 1. Use only propane/LP gas. Do not convert heater to use different fuel type. 2. Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors. 3. This heater shall not be installe[...]

  • Page 4

    4 101827 PRODUCT IDENTIFICA TION GRH/PV 006A COMFORT GLOW PLAQUE FRONT-NON THERMO Burners Heater Cabinet Front Panel Grill Guard PRODUCT FEA TURES Safety Device This heater has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent-free room heaters. The ODS/pilot shuts off the heater if there is [...]

  • Page 5

    5 101827 Unconfined Space The National Fuel Gas Code, ANSIZ223.1, 1992, Section 5.3 defines uncon- fined space as having a minimum air volume of 50 cubic feet (127 cubic cm) for each 1000 Btu/Hr input rating of all appliances in the space (cubic feet equals length x width x height of space). Include adjoining rooms only if there are doorless passag[...]

  • Page 6

    6 101827 AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation[...]

  • Page 7

    7 101827 AIR FOR COMBUSTION AND VENTILA TION Continued Figure 2 - Ventilation Air from Inside Building Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 Continued WARNING ICON G001 W ARNING If the area in which the heater may be operated i[...]

  • Page 8

    8 101827 AIR FOR COMBUSTION AND VENTILA TION Continued VENTILATION AIR (Continued) Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open t[...]

  • Page 9

    9 101827 IMPORT ANT : V ent-free heaters add moisture to the air . Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air f or Comb ustion and V entilation, pages 5 through 8. INST ALLING T O W ALL NOTICE A qualified service person must install heater. Follow a[...]

  • Page 10

    10 101827 Minimum From Sides Of Heater 36" 3" FLOOR CEILING Minimum Minimum To Top Surface Of Carpeting, Tile Or Other Combustible Material 8" Left Side Right Side Figure 4 - Mounting Clearances As Viewed From Front of Heater INST ALLING T O W ALL Continued CAUTION If you install the heater in a home garage • heater pilot and burne[...]

  • Page 11

    11 101827 INSTALLING HEATER TO WALL Mounting Bracket The mounting bracket is located on back panel of heater. It has been taped there for shipping. Remove mounting bracket from back panel. Methods For Attaching Mounting Bracket To Wall Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 16 inches apart [...]

  • Page 12

    12 101827 Marking Screw Locations 1. Tape mounting bracket to wall where heater will be located. Make sure mount- ing bracket is level. 2. Mark screw locations on wall (see Figure 7). Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only. 3. Remove tape and mounting bracket from wall. Figure 7 - [...]

  • Page 13

    13 101827 4. For thin walls (1/2" or less), insert red key into wall anchor. Push red key to “pop” open anchor wings. IMPORTANT: Do not hammer key! For thick walls (over 1/2" thick) or solid walls, do not pop open wings. Figure 9 - Popping Open Anchor Wings For Thin Walls 5. Place mounting bracket onto wall. Line up last hole on each [...]

  • Page 14

    14 101827 CONNECTING T O GAS SUPPL Y NOTICE A qualified service person must connect heater to gas supply. Follow all local codes. CAUTION Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe of large enough diameter to allow proper gas volume to heater. If pipe is too[...]

  • Page 15

    15 101827 IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings. Tee Joint Reducer Bushing to 1/8" NPT 1/8" NPT Plug Tap Test Gauge Connection * Tee Joint Pipe Nipple Cap Manual Shutoff Valve * 1/2" NPT Pipe Nipple Heater Cabinet Pressure Regulator Figure 13 - Gas Connection 3" Minimum G[...]

  • Page 16

    16 101827 3. Pressurize supply piping system by either using compressed air or opening propane/LP supply tank valve. 4. Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak. 5. Correct all leaks at once. Test Pressures Equal To or Less Than 1/2 PSIG 1. Close manual shutoff v[...]

  • Page 17

    17 101827 OPERA TING HEA TER FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floo[...]

  • Page 18

    18 101827 4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information at the top of page 17. If you don’t smell gas, go to the next step. 5. Press in control knob. Note: You may be running this heater for the first time after hooking up to gas supply[...]

  • Page 19

    19 101827 TO SELECT HEA TING LEVEL 1. Slightly press in control knob and turn counterclockwise to the LOW, MEDIUM, or HIGH positions. IMPORTANT: Release downward pressure while turning control knob. Control knob will lock at the desired position. CAUTION Do not try to adjust heating levels by using the manual shut- off valve. LOW OFF PILOT IGN MED [...]

  • Page 20

    20 101827 Shutting Off Heater 1. Turn control knob clockwise to the OFF position. 2. Turn off all electric power to the appliance if service is to be performed. Shutting Off Burner Only (pilot stays lit) 1. Turn control knob clockwise to the PILOT position. MANUAL LIGHTING PROCEDURE 1. Follow steps 1 through 6 under Lighting Instructions , pages 17[...]

  • Page 21

    21 101827 Bad Burner Pattern 5 Plaque GRH/OV 019A Figure 22 - Incorrect Burner Flame Pattern If burner flame pattern is incorrect, as shown in Figure 22 • turn heater off (see To Turn Off Gas to Appliance , page 20) • see Troubleshooting , pages 22 through 25 Figure 21 - Correct Burner Flame Pattern INSPECTING BURNER Continued BURNER FLAME PATT[...]

  • Page 22

    22 101827 CLEANING AND MAINTENANCE ODS/PILOT AND BURNER ORIFICE • Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean. CABINET Air Passageways • Use a vacuum cleaner or pressurized air to clean. Exterior • Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabinet to remove dust. TROUBLE- SHOOTING[...]

  • Page 23

    23 101827 REMEDY 1. Turn on gas supply or open manual shutoff valve 2. Press in control knob while turning to PILOT/IGN position 3. Continue holding down control knob. Repeat igniting operation until air is removed 4. Contact local propane/ LP gas company. 5. Clean ODS/pilot (see Cleaning and Mainte- nance , page 22) or replace ODS/pilot assembly 6[...]

  • Page 24

    24 101827 OBSERVED PROBLEM Burner(s) does not light after ODS/pilot is lit Delayed ignition of burner(s) Burner backfiring during combustion Burner plaque(s) does not glow Slight smoke or odor during initial operation Heater produces a clicking/ticking noise just after burner is lit or shut off POSSIBLE CAUSE 1. Burner orifice(s) is clogged 2. Burn[...]

  • Page 25

    25 101827 TROUBLE- SHOOTING Continued If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, c[...]

  • Page 26

    26 101827 SPECIFICA TIONS CGP16RA CGP26D BTU (Variable) 6,000/11,000/16,000 6,000/16,000/26,000 Type Gas Propane/LP Only Propane/LP Only Ignition Piezo Piezo Pressure Regulator Setting 8" W.C. 8" W.C. Inlet Gas Pressure (in. of water) Maximum 14" 14" Minimum 11" 11" Dimensions, Inches (H x W x D) Heater 23.5 x 18.5 x 8[...]

  • Page 27

    27 101827 MANUAL SHUTOFF VALVE - GA5010 Manual shutoff valve with 1/8" NPT tap. FLOOR MOUNTING STAND Model CGP16RA - GA4000B and GA4500 Model CGP26D - GA4010B and GA4510 For locating heater on the floor, away from a wall. Complete installation instructions included. ACCESSORIES Purchase these heater accessories from your local dealer. If they [...]

  • Page 28

    28 101827 HEATER EXPLODED VIEW ILLUSTRA TED P ARTS BREAKDOWN Model CGP16RA 13-15 13-14 ODS/PILOT BURNER ASSEMBLY A B C 13-1 13-2 13-3 13-10 13-4 13-5 13-6 13-7 13-8 13-9 13-12 13-13 13-11 1 2 3 11 6 4 8 5 6 7 12 13 9 10 14[...]

  • Page 29

    29 101827 P ARTS LIST Model CGP16RA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. PARTS AVAILABLE - NOT SHOWN KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 098742-03 Front Panel 1 3 098238-06 Grill Guard 1[...]

  • Page 30

    30 101827 HEATER EXPLODED VIEW ILLUSTRA TED P ARTS BREAKDOWN Model CGP26D 13-15 13-14 ODS/PILOT BURNER ASSEMBLY E D C 13-1 13-2 13-3 13-9 13-4 13-5 13-7 13-6 13-8 13-10 13-12 13-13 13-11 B A 1 2 3 11 6 13 4 8 5 6 7 12 9 10 14[...]

  • Page 31

    31 101827 This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. P ARTS LIST Model CGP26D PARTS AVAILABLE - NOT SHOWN KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 098742-04 Front Panel 1 3 098238-07 Grill Guard 1 [...]

  • Page 32

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. 2701 Ind[...]