Go to page of
Similar user manuals
-
Electric Heater
Desa 3VH22
10 pages 0.55 mb -
Electric Heater
Desa B350D
20 pages 0.39 mb -
Electric Heater
Desa CGB3930NR
28 pages 0.94 mb -
Electric Heater
Desa NTH50-2
28 pages 0.6 mb -
Electric Heater
Desa LSFG20PT
48 pages 2.4 mb -
Electric Heater
Desa LSF20NT
48 pages 2.4 mb -
Electric Heater
Desa VP10A
32 pages 3.23 mb -
Electric Heater
Desa CBP20T
32 pages 1.52 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Desa DNV25PB, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa DNV25PB one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Desa DNV25PB. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Desa DNV25PB should contain:
- informations concerning technical data of Desa DNV25PB
- name of the manufacturer and a year of construction of the Desa DNV25PB item
- rules of operation, control and maintenance of the Desa DNV25PB item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa DNV25PB alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa DNV25PB, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa DNV25PB.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa DNV25PB item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Save this manual for future reference. SOLID STATE IGNITION 50 60 70 80 90 50 60 70 80 90 D YNA VENT WINDOW W ALL FURNACE DIRECT -VENT PROP ANE/LP GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL DNV25PB DNV40PB 25,000 and 40,000 BTU/Hr “B” Model Furnaces FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and l[...]
-
Page 2
2 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® 6. This furnace must have fresh air for proper operation. If not, poor fuel combustion and improper venting of flue gases will result. Carbon monoxide poisoning from backed- up flue gases could occur . The State of California lists carbon monoxide as a re- productive toxin under Proposition[...]
-
Page 3
3 201839 OWNER’S MANUAL LOCAL CODES UNP ACKING 1. Remove furnace from carton. 2. Remove all protective packaging ap- plied to furnace for shipment. 3. Remove the following items from carton: • Hardware package containing four large screws, two small screws, and thermostat mounting plate • Hardware package (thermostat and two screws) • Equip[...]
-
Page 4
4 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® 6" Minimum Adjacent Side Wall Ceiling Finished Floor, Carpet, Tile, etc. 12" Minimum 12" Minimum Figure 1 - Mounting Clearances as Viewed from Front of Furnace The clearance between the cabinet and the wall it passes through is 0 inches. Provide the following minimum clearanc[...]
-
Page 5
5 201839 OWNER’S MANUAL CREATING WALL OPENING AND MOUNTING FURNACE Remove furnace front cover. Remove the two screws at the lower edges of front cover. Lift front cover away. Installing in Normal Frame Wall The 25,000 BTU/Hr model is designed to fit between two wall studs set at 16 inch on center. The 40,000 BTU/Hr model will not fit between wall[...]
-
Page 6
6 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® 6. Attach thermostat to thermostat mount- ing plate with screws provided (see Fig- ure 4). IMPOR T ANT : Note mounting plate position in Figure 4. Correctly position mounting plate for your model furnace. 7. Insert thermostat mounting plate be- tween wall and cabinet flange. Line up top not[...]
-
Page 7
7 201839 OWNER’S MANUAL 10. Feed thermostat wires from attic to furnace through 1/2" hole in ceiling wall plate. 1 1. Connect thermostat wires from attic to thermostat wires on furnace. Connect red wires together , then connect white wires together . Use wire nuts to make connections. IMPORT ANT : Make sure thermostat wires do not touch comb[...]
-
Page 8
8 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. Connecting Furnace to Gas Supply at Rear of Furnace 1. Remove the two screws in back of fur- nace cabinet located by the exha[...]
-
Page 9
9 201839 OWNER’S MANUAL CAUTION: Never connect heater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply. The installer must supply an external regulator. The external regulator will reduce incoming gas pressure. You must reduce inco[...]
-
Page 10
10 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® INST ALLA TION (Continued) Installation must include an equipment shutoff valve (supplied), ground joint union, plugged 1/8" NPT tap, and a sediment trap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from furnace (see Figure 15). Install an equipment sh[...]
-
Page 11
11 201839 OWNER’S MANUAL Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig- ure 16). 2. Pressurize supply piping system by either using compressed air or opening main gas valve located on or near gas meter . 3 . Check all joints from gas meter to equipment shutoff valve. Apply mix- ture of liquid so[...]
-
Page 12
12 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® WARNING: Furnace burner, combustion chamber, and ex- haust port are very hot during operation. Keep children and adults away from hot surfaces to avoid burns and clothing igni- tion. Carefully supervise young children when they are in the same room as furnace. Furnace will remain hot for a[...]
-
Page 13
13 201839 OWNER’S MANUAL OPERA TING FURNACE (Continued) 1. Set thermostat to lowest setting 2. T ur n equipment gas valv e clockwise to OFF position. Do not for ce equipment gas valve. 3. Unplug furnace if service is to be per - for med. To Shut Down Furnace for an Extended Period of Time 1. T ur n equipment gas valv e clockwise to OFF position. [...]
-
Page 14
14 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® WARNING: Turn off and un- plug furnace and let cool before cleaning. Turn equipment shutoff valve to OFF position. Only a qualified service person should service and repair furnace. WARNING: Keep furnace clear and free from combustible mate- rials, gasoline, and other flam- mable vapors an[...]
-
Page 15
15 201839 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off and unplug furnace and let cool before servic- ing. Unless you need gas supply for testing, shut off equipment shutoff valve before servicing. Only a qualified service person should service and repair furnace. Continued www.desatech.com Note: For additional help, visit DESA International?[...]
-
Page 16
16 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® TROUBLESHOOTING Continued www.desatech.com The electronic system is made up of two parts: the ignition control and the glo bar. The ignition control is the brain of the elec- tronic system. It has several functions: 1. When the blower reaches full r .p.m., a 24-volt circuit is completed to[...]
-
Page 17
17 201839 OWNER’S MANUAL www.desatech.com OBSERVED PROBLEM Ignition failures POSSIBLE CAUSE 1. Glo bar will not glow - with blower run- ning and microswitch engaged 2. Glo bar glows but burner will not come on 3. Glo bar operating and gas valve open- ing but burner will not light 4. If the ignitor remains on after main burner ignition or the valv[...]
-
Page 18
18 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® www.desatech.com OBSERVED PROBLEM Ignition failures Excessive noise Main burner will not cycle off Furnace will not operate POSSIBLE CAUSE 5. Burner cycles off and glo bar comes on immediately , check the following: 1. Blower out of balance 2. Motor hums 1. Thermostat setting 2. Gas valve [...]
-
Page 19
19 201839 OWNER’S MANUAL 1 2 3 4 5 6 7 Junction Box Black Green ▲ White Black White White Black Transformer White Brown Brown Black Motor Green 370 V.A.C. Capacitor 5 MFD Terminal Block Black Thermostat White Red Black Yellow Blue Brown Green Black Brown White Ignition Control Board Probe ♦ Black White White Glo-Bar Gas Valve Time Delay Relay[...]
-
Page 20
20 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® These Parts Centrals are privately owned businesses. They have agreed to support our customer’s needs by providing original replacement parts and accessories. For certain parts, some Parts Centrals may refer you to a dealer in your area. When calling a Parts Central, ask for the Parts De[...]
-
Page 21
21 201839 OWNER’S MANUAL KEY PART NO. NUMBER DESCRIPTION QTY. 1 030643 Front Cover Assembly 1 2 121520 Screw, #8 x 3/8" ** 2 3 191240 Front Cover Trim* 1 4 160912 Thermostat 1 5 100892 Cabinet Assembly 1 6 070509 Cabinet Insulation (right and left sides) 1 7 121224 Screw, #10 x 3/4" ** 4 8 062242 Thermostat Mounting Plate 1 ∆ 070542 C[...]
-
Page 22
22 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® ILLUSTRA TED P AR TS LIST CABINET ASSEMBLY 40,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. 2 5 6 1 7 4 9 8 10 SOLID STATE IGNITION 50 60 70 80 90 50 60 70 8[...]
-
Page 23
23 201839 OWNER’S MANUAL ILLUSTRA TED P AR TS LIST COMBUSTION CHAMBER ASSEMBLY 25,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 121357 Screw, #6 x 5/8" ** 4 2 231955 Wire [...]
-
Page 24
24 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® ILLUSTRA TED P AR TS LIST COMBUSTION CHAMBER ASSEMBLY 40,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 121502 Screw, #[...]
-
Page 25
25 201839 OWNER’S MANUAL ILLUSTRA TED P AR TS LIST BURNER ASSEMBLY 25,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. 1 2 3 4 5 6 7 8 9 10 11 12 KEY PART NO. NUMBER DESCRIPTION QTY. 1 120717 Hex Nut, #10-24 ** 2 2 121[...]
-
Page 26
26 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® ILLUSTRA TED P AR TS LIST BURNER ASSEMBLY 40,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 120717 Hex Nut, #10-24 ** 4[...]
-
Page 27
27 201839 OWNER’S MANUAL ILLUSTRA TED P AR TS LIST BLOWER ASSEMBLY 25,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. 1 2 3 4 6 5 7 8 9 10 11 12 13 17 15 16 17 17 18 19 20 21 22 23 14 24 25 23 KEY PART NO. NUMBER DESC[...]
-
Page 28
28 201839 DIRECT -VENT PROP ANE/LP GAS HEA TER DYNA VENT ® ILLUSTRA TED P AR TS LIST BLOWER ASSEMBLY 40,000 BTU/HR MODEL This list contains replaceable parts used in your furnace. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 070570 Combustion Air Cover[...]
-
Page 29
29 201839 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________[...]
-
Page 30
LIMITED WARRANTY DYNAVENT GAS WALL FURNACE DESA International warrants this product to be free from defects in materials and components for one (1) year and five (5) years on the combustion chamber/heat exchanger assembly from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance wi[...]