Go to page of
Similar user manuals
-
Indoor Fireplace
Desa LEP) (V)L36(ZNR
44 pages 2.76 mb -
Indoor Fireplace
Desa 36WS
11 pages 1.24 mb -
Indoor Fireplace
Desa L32, L36 L36, L42, L32, L36, L36, L42
44 pages 2.76 mb -
Indoor Fireplace
Desa VMH10TPB
44 pages 4.97 mb -
Indoor Fireplace
Desa FMH26TN 14
28 pages 0.82 mb -
Indoor Fireplace
Desa BHDV41N/P
44 pages 1.29 mb -
Indoor Fireplace
Desa (V)KC42N Series
40 pages 2.32 mb -
Indoor Fireplace
Desa LGCFTP
32 pages 1.63 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Desa M42E, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa M42E one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Desa M42E. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Desa M42E should contain:
- informations concerning technical data of Desa M42E
- name of the manufacturer and a year of construction of the Desa M42E item
- rules of operation, control and maintenance of the Desa M42E item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa M42E alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa M42E, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa M42E.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa M42E item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
MODELS M36E(B,H), M42E(B,H), VM36E(B,H) AND VM42E(B,H) ELECTRONIC IGNITION - NA TURAL GAS This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other[...]
-
Page 2
108796 2 For more information, visit www.desatech.com For more information, visit www.desatech.com TABLE OF CONTENTS SAFETY INFORMA TION ............................................................ 2 UNP ACKING ............................................................................... 3 INTRODUCTION ............................................[...]
-
Page 3
108796 3 3 For more information, visit www.desatech.com For more information, visit www.desatech.com SAFETY INFORMATION UNPACKING 8. T urn fireplace of f and let cool before servicing or repairing. Only a qualified service person should install, service, or re- pair this fireplace. Have fireplace inspected annually by a quali- fied service person. [...]
-
Page 4
108796 4 For more information, visit www.desatech.com For more information, visit www.desatech.com GAS RATING - NATURAL M36E(B,H)/VM36E(B,H) M42E(B,H)/VM42E(B,H) Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 3.5 in. WC (.87 kPa) 3.5 in. WC (.87 kPa) Minimum Supply Pressure: 4.5 in. WC (1.12 kPa) 4.5 in. WC (1.12 kPa) Maximum Sup[...]
-
Page 5
108796 5 5 For more information, visit www.desatech.com For more information, visit www.desatech.com PRODUCT SPECIFICATIONS S T P Q R X Outside Air Kit Location (Optional) K 7" J I M L P V 13.5" S 1.5" Glass Door (Optional) W T O N Alternate Gas Supply Inlet 7" G H F A Stand Off Collar For Use With 6"Ø Type B-1 Vent Pipe O[...]
-
Page 6
108796 6 For more information, visit www.desatech.com For more information, visit www.desatech.com CLEARANCES Minimum clearances to combustibles are: • Back and Sides of Outer Surround ............................ 0" min. • Drywall to Sides of Front Face (Nailing Flanges) ... 0" min. • “B” V ent Surfaces ........................[...]
-
Page 7
108796 7 7 For more information, visit www.desatech.com For more information, visit www.desatech.com MANTEL CLEARANCES AND WALL DETAILS A combustible mantle shelf maybe installed a maximum 12 " (229 mm) from the wall. Figures 5 and 6 show the minimum allowable distances from various combustible mantle components in relation to the fire- place [...]
-
Page 8
108796 8 For more information, visit www.desatech.com For more information, visit www.desatech.com PRE-INST ALLA TION PREP ARA TION Continued PRE-INSTALLATION PREPARATION Framing Installing Transition Vent Collar FRAMING 1. Frame appliance enclosure as illustrated in Figures 7 and 8. Note: If a wall co vering is used to line the enclosure, then all[...]
-
Page 9
108796 9 9 For more information, visit www.desatech.com For more information, visit www.desatech.com VENTING INST ALLA TION A B-type venting system must be connected to the appliance for venting to the outside of the building. The following section is provided as a guide to a standard B-type vent installation. Standing codes requirements concerning[...]
-
Page 10
108796 10 For more information, visit www.desatech.com For more information, visit www.desatech.com CHECKING FOR PROPER VENTING After completing and checking the electrical, gas and vent connec- tions, follow the lighting instructions and allow the main burner to run for approximately 5 minutes. Hold a lighted match or cigarette near the top edge o[...]
-
Page 11
108796 11 11 For more information, visit www.desatech.com For more information, visit www.desatech.com INST ALLA TION INSTALLATION Wall Switch Installation Optional Remote Control Installation Gas Line Hook-Up OPTIONAL REMOTE CONTROL INSTALLATION (Model WRC) Note: If using optional wireless hand-held remote control, the wall switch must be in the O[...]
-
Page 12
108796 12 For more information, visit www.desatech.com For more information, visit www.desatech.com EMBER AND PAN MATERIAL PLACEMENT 1. Open the bag(s) of vermiculite and fill the entire burner pan until the burner tube is completely covered (see Figure 20). 2. Smooth the pan material just even with edges of the burner pan. 3. Remove the ember mate[...]
-
Page 13
108796 13 13 For more information, visit www.desatech.com For more information, visit www.desatech.com LOG PLACEMENT FOR M36E/VM36E MODELS 1. Place small front right log (log 1) on right front of grate as shown in Figure 23. 2. Place large back log (log 2) onto grate making sure notches rest over grate as shown in Figure 23. 3. Place log 3 across l[...]
-
Page 14
108796 14 For more information, visit www.desatech.com For more information, visit www.desatech.com INST ALLA TION Continued LOG PLACEMENT FOR M42E/VM42E MODELS 1. Place log 1A on the front left side of grate. Place log 1B on the front right side of the grate. See Figure 27. 2. Place large back log (log 2) onto grate making sure notches rest over g[...]
-
Page 15
108796 15 15 For more information, visit www.desatech.com For more information, visit www.desatech.com COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through the outside wall or a ventilated crawl space. The handle to operate the damper door for the outs[...]
-
Page 16
108796 16 For more information, visit www.desatech.com For more information, visit www.desatech.com 5. Once the top and bottom pins are secured, unfold the door into the closed position. 6. Repeat the process for the opposite door assembly . 7. T o adjust the doors, slide them partially open. Using a scre w- driv er , loosen the hold-down scre ws i[...]
-
Page 17
108796 17 17 For more information, visit www.desatech.com For more information, visit www.desatech.com Figure 37 - Turning Equipment Shutoff Valve to the OFF Position TO TURN OFF GAS TO APPLIANCE 1. T urn off the wall switch. 2. T urn off all electric power to the appliance if service is to be perf ormed. 3. Fully open glass doors if installed. 4. [...]
-
Page 18
108796 18 For more information, visit www.desatech.com For more information, visit www.desatech.com CLEANING AND MAINTENANCE WARNING: The logs can be hot. Handle only when cool. WARNING: Turn off gas and electrical power before servicing appliance. WARNING: Installation and repair should be done by a qualified service person. The appliance should b[...]
-
Page 19
108796 19 19 For more information, visit www.desatech.com For more information, visit www.desatech.com Robertshaw MODEL SP745 IGNITION CONTROL STEP DOWN TRANSFORMER PV GND PV/MV TR MV TH VENT SAFETY SHUTOFF SWITCH MANUAL DAMPER SWITCH IGN EV2 SUPPLY INCOMING MAIN GAS EV1 TO GAS LINE BURNER 24V AC 120V AC 120V AC INCOMING OR BREAKER) (FUSE BOX OFF O[...]
-
Page 20
108796 20 For more information, visit www.desatech.com For more information, visit www.desatech.com TROUBLESHOOTING The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter OBSERVED PROBLEM Ignitor will not spark or pilot will not light Pi[...]
-
Page 21
108796 21 21 For more information, visit www.desatech.com For more information, visit www.desatech.com TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighb[...]
-
Page 22
108796 22 For more information, visit www.desatech.com For more information, visit www.desatech.com ILLUSTRA TED P AR TS BREAKDOWN M36E(B,H),M42E(B,H), VM36E(B,H) AND VM42E(B,H) MODELS ILLUSTRATED PARTS BREAKDOWN M36E(B,H),M42E(B,H), VM36E(B,H) AND VM42E(B,H) Models 51 21 3 25 2 1 10 11 6 57 57 22 50 18 9 8 17 70 68 65 67 52 13 61 14 45 43 48 59/60[...]
-
Page 23
108796 23 23 For more information, visit www.desatech.com For more information, visit www.desatech.com KEY M36E(B,H) M42E( B, H) NO. VM36E(B,H) VM42E(B,H) DESCRIPTION QTY. 1 14574 106543-01 Limit Switch 1 2 106638-01 107797-01 Insulation Pan 1 3 106639-01 107798-01 Fireplace Top Assembly 1 4 106641-01 107800-01 Fireplace Surround 1 5 106642-01 1066[...]
-
Page 24
108796 24 For more information, visit www.desatech.com For more information, visit www.desatech.com ILLUSTRA TED P AR TS BREAKDOWN LOGS FOR M36E(B,H),M42E(B,H), VM36E(B,H) AND VM42E(B,H) MODELS 6 4 1A 1B 3 5 2 Logset for M36E(B,H) and VM36E(B,H) Models Logset for M42E(B,H) and VM42E(B,H) Models KEY PART NO. NUMBER DESCRIPTION QTY. - 107999-01 Log S[...]
-
Page 25
108796 25 25 For more information, visit www.desatech.com For more information, visit www.desatech.com ACCESSORIES AIR KIT AK4 - Optional kit helps offset the negative pressure often existing in today's tightly constructed homes. REMOTE CONTROL KITS WRC - Standard On/Off Electronic Remote Control Kit PROPANE CONVERSION KITS PCBE-36 - Propane C[...]
-
Page 26
108796 26 For more information, visit www.desatech.com For more information, visit www.desatech.com LIMITED WARRANTY B-VENT FIREPLACE DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and mai[...]