Go to page of
Similar user manuals
-
Gas Heater
Desa FBS-10BB
26 pages 0.49 mb -
Gas Heater
Desa GN30
28 pages 3.15 mb -
Gas Heater
Desa TD120A
24 pages 4.77 mb -
Gas Heater
Desa LSL18NT, LSL18PT, SL18NT, SL18PT, VSL18NT, VSL18PT
56 pages 3.37 mb -
Gas Heater
Desa RCCP80V
28 pages 1.69 mb -
Gas Heater
Desa FG30P
32 pages 1.24 mb -
Gas Heater
Desa CGP11
24 pages 0.22 mb -
Gas Heater
Desa FG30NT
32 pages 1.24 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Desa MP10T, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa MP10T one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Desa MP10T. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Desa MP10T should contain:
- informations concerning technical data of Desa MP10T
- name of the manufacturer and a year of construction of the Desa MP10T item
- rules of operation, control and maintenance of the Desa MP10T item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa MP10T alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa MP10T, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa MP10T.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa MP10T item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
VENT -FREE GAS HEA TER SAFETY INFORMA TION AND INST ALLA TION MANU AL GWN6, GWP6, GWN10, GWP10, GWN10T , GWP10T , GWRN10, GWRP10, MN10T , MP10T , VN1000BT A, VP1000BT A, VN10A, VP10A, VN10T A, VP10T A, VN6D, VP5D, WMN10, WMP10 For more information, visit www .desatech.com W ARNING: If the information in this manual is not followed exactly , a re[...]
-
Page 2
www .desatech.com 123995-01C 2 SAFETY This appliance may be in - stalled in an aftermarket,* p e r m a n e n t l y l o c a t e d , manufactured (mobile) home, where not prohib - ited by local codes. * Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer WARNING: This product con - tains and/or generates chemicals known [...]
-
Page 3
www .desatech.com 123995-01C 3 Natural and Propane/LP Gas: Natural and propane/LP gases are fuel gases. Fuel gases are odorless. An odor-making agent is added to fuel gases. The odor helps you detect a fuel gas leak. However, the odor added to fuel gas can fade. Fuel gas may be present even though no odor exists. Make certain you read and understan[...]
-
Page 4
www .desatech.com 123995-01C 4 1 1. Do not use heater if any part has been under water . Immediately call a qualied ser vice te chni cian to in spec t t he room heater and to replace any part of the control system and any gas control which has been under water . 12. Turn off heater and let cool before servic - ing . Only a qual ie d ser vic e[...]
-
Page 5
www .desatech.com 123995-01C 5 W ARNING: This heater shall not be installed in a room or space un - less the required volume of indoor combustion air is provided by the method described in the National Fuel Gas Code, ANSI Z223.1/NFP A 54, the International Fuel Gas Code, or applicable local codes. Read the following instructions to insure proper fr[...]
-
Page 6
www .desatech.com 123995-01C 6 AIR FOR COMB USTION AND VENTILA TION Continued DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCA TION Determining if Y ou Have a Conned or Unconned Space Use this work sheet to determine if you have a conned or unconned space. Space: Include s the room in which you will instal l replace plus any adjoining r[...]
-
Page 7
www .desatech.com 123995-01C 7 V entilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. Y ou must provide two perma - nent openings: one within 12" of the ceiling Or Remove Door into Adjoining Room, Option 3 V e ntilation Grills Into Adjoining Room, Option 2 12" 12" V e ntilation Grills into Adjoin[...]
-
Page 8
www .desatech.com 123995-01C 8 LOCA TING HEA TER This heater is designed to be mounted on a wall. W ARNING: Maintain the minimum clearances shown in Figure 4. If you can, provide greater clearances from oor , ceiling and joining wall. W ARNING: Never install the heater • in a bathroom (10,000 Btu/hr only . 6,000 Btu/hr models are allowed in a [...]
-
Page 9
www .desatech.com 123995-01C 9 INST ALLING HEA TER TO W ALL Marking Screw Locations 1. Determine where you will locate heater . W ARNING: Maintain mini - mu m clea ra nc es sh ow n in Figu re 5. If you can, provide greater clearances from oor and join - ing wall. 2. Mark two mounting screw locations on wall (see Figure 5). INST ALLA TION Continu[...]
-
Page 10
www .desatech.com 123995-01C 10 INST ALLA TION Continued Removing Front Panel Of Heater 1. Remove two screws near bottom corners of front panel. 2. Lift straight up on grill guard until it stops. Grill guard will slide up about 1/4". 3. Pull bottom of front panel forward, then down. Figure 10 - Removing Front Panel Of Heater Installing Bottom [...]
-
Page 11
www .desatech.com 123995-01C 11 Installation must include equipment shutoff val ve, uni on and plug ged 1/8 " NPT tap . Lo cat e NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13). IMPORT ANT : Install an equipment shutoff valve in an accessible location. The equip - ment shutoff valve is for turn[...]
-
Page 12
www .desatech.com 123995-01C 12 T est Pressures Equal T o or Less Than 1/2 PSIG (3.5 kPa) 1. Close equipment shutoff valve (see Fig - ure 14). 2. Pressuri ze supply piping system by either opening propane/LP supply tank valve for propane/LP gas or opening main gas valve located on or near gas meter for natural gas, or using compressed air . 3. Chec[...]
-
Page 13
www .desatech.com 123995-01C 13 INST ALLA TION Continued OPERA TION PRESSURE TESTING HEA TER GAS CONNECTIONS 1. Open equip ment shut off valv e (see Figu re 14, page 12). 2. For nat ura l gas open main gas val ve loca t - ed on or near gas meter . For propane/LP gas open propane/LP supply tank valve. 3. Make sure control knob of heater is in the OF[...]
-
Page 14
www .desatech.com 123995-01C 14 8. Keep control knob pressed in for 30 sec - onds after lighting pilot. After 30 seconds, release control knob. • If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs. Note: If pilot goes out, repeat steps 4 thru 7. Wait one (1) minute before lighting pilot a[...]
-
Page 15
www .desatech.com 123995-01C 15 OPERA TION Continued MANU AL CONTROL INFRARED MODELS ONL Y TO SELECT HEA TING LEVEL W ARNING: Wh en running heater , set control knob at LOW or HIGH locked positions for double burner heater or ON po - sition for single burner heater . Never set control knob between locked positions. Poor combus - tion and higher lev[...]
-
Page 16
www .desatech.com 123995-01C 16 1/2 GLASS HEIGHT CORRECT FLAME P A TTERN A T HIGH POSITION INCORRECT FLAME P A TTERN A T HIGH POSITION 1/2 GLASS HEIGHT 1/2 GLASS HEIGHT CORRECT FLAME P A TTERN A T HIGH POSITION INCORRECT FLAME P A TTERN A T HIGH POSITION 1/2 GLASS HEIGHT Figure 23 - Correct Burner Flame Pattern Y ellow T ipping Figure 24 - Incorrec[...]
-
Page 17
www .desatech.com 123995-01C 17 CLEANING dirt, lint and pet hair . T o clean these parts we recommend using compressed air no greater than 30 PSI. Y our local computer store, hardware store or home center may carry compressed air in a can. If using compressed air in a can, pleas e follow the direc tions on the can. If you don’t follow directions [...]
-
Page 18
www .desatech.com 123995-01C 18 TROUBLESHOO TING W ARNING: T urn off heater and let cool before servicing. Only a qualied service person should service and repair heater . CAUTION: Never use a wire, needle or similar object to clean ODS/pilot. This can damage ODS/pilot unit. Note: All troubleshooting items are listed in order of operation. POSSI[...]
-
Page 19
www .desatech.com 123995-01C 19 OBSERVED PROBLEM ODS/pilot lights but ame goes out when control knob is released Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Burner plaque(s) does not glow (Infrared models only) Y ellow ame during burner combustion TROUBLESHOO TING Continued REMED[...]
-
Page 20
www .desatech.com 123995-01C 20 TROUBLESHOO TING Continued OBSERVED PROBLEM Heater shuts of f in use (ODS operates) Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit Heater produces a clicking/ ticking noise just after burner is lit or shut off Whit e powd er res idue formin g within burner box or on[...]
-
Page 21
www .desatech.com 123995-01C 21 W ARNING: If you smell gas • Shut off gas supply . • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone. Fol - low the gas supplier ’ s instructions. • If you cannot reach your gas[...]
-
Page 22
www .desatech.com 123995-01C 22 15 25 17 19 1 2 3 5 6 7 8 9 4 12 13 14 15 18 16 17 9 20 21 23 22 24 13 10 1 1 P ARTS MODELS GWP6, GWN6, GWP10, GWN10, GWP10T , GWN10T , MN10T , MP10T , VN1000BT A, VP1000BT A, WMN10, WMP10 Pilot 1 1-1 1 1-2[...]
-
Page 23
www .desatech.com 123995-01C 23 P ARTS LIST This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 21 of this manual. KEY NO. P ART NO. DESCRIPTION QTY . 1 098304-01 Screw , #10 x 3/8" • • • • • • 2 2 099467-03 Front Panel Assembly • • 1 0994[...]
-
Page 24
www .desatech.com 123995-01C 24 A B 1 1 24** 19* * Manual Control Models Only ** Thermostat Control Models Only 18* 16 15 14* 13* 10* 12* 9 9 1 1 20 7 8 8 (VP5D and VN6D Models Only 6 5 4 3 2 1 21* 22 17 17 25** 9 23** P ARTS MODELS GWRP10, GWRN10, VP5D, VN6D, VP10A, VN10A, VP10T A, VN10T A Pilot 1 1-1 1 1-2[...]
-
Page 25
www .desatech.com 123995-01C 25 KEY NO. P ART NO. DESCRIPTION QTY . 1 098304-01 Screw, #10 x 3/8" • • • • • • • • 2 2 099467-03 Front Panel Assembly • • • • • • 1 099467-07 Front Panel Assembly • • 1 3 099318-03 Grill Guard • • • • • • • • 1 4 101 108-01 Grill Guard Clip • • • • • • ?[...]
-
Page 26
www .desatech.com 123995-01C 26 SPECIFICA TIONS BLUE FLAME MODELS GWP6 • 4,400/6,000 Btu/hr (V ariable) • Propane/LP Gas • Piezo Ignition • Pressure Regulator Setting: 8" W .C. • Inlet Gas Pressure (inches of water): Maximum - 14" wc, Minimum - 1 1" wc GWN6 • 4,400/6,000 Btu/hr (V ariable) • Natural Gas • Piezo Igniti[...]
-
Page 27
www .desatech.com 123995-01C 27 ACCESSOR Y Those Heater Guys 255 E. Stowell Street Upland, CA 91786 909-982-301 1 T ool & Equipment Co. 5 Manila Ave Hamden, CT 06514 1-800-397-7553 203-248-7553 Portable Heater Parts 342 N. County Rd. 400 East V alparaiso, IN 46383 219-462-7441 1-888-619-7060 www .portableheaterparts.com sales@portableheaterpart[...]
-
Page 28
123995-01 Rev . C 09/08 DESA Heating, LLC 2701 Industrial Drive Bowling Green, KY 42101 www .desatech.com 1-866-672-6040[...]
-
Page 29
GWN6, GWP6, GWN10, GWP10, GWN10T , GWP10T , GWRN10, GWRP10, MN10T , MP10T , VN1000BT A, VP1000BT A, VN10A, VP10A, VN10T A, VP10T A, VN6D, VP5D, WMN10, WMP10 CALENT ADOR DE GAS NO VENTILADO (SIN VENTILAS) INFORMACIÓN DE SEGURID AD Y MANUAL DE INST ALACIÓN Para obtener más información visite www .desatec h.com AD V ER TE NC IA : si la in fo rm ac[...]
-
Page 30
www .desatech.com 123995-01C 2 SEGURID AD ADVERTENCIA: la ins - talación, ajuste, alteración, servicio o mantenimiento inadecuados pueden pro - vocar lesiones o daños a la propiedad. Consulte este manual para conocer los procedimientos de instala - ción y operación correctos. Para obtener asistencia o información adicionales consulte a un ins[...]
-
Page 31
www .desatech.com 3 123995-01C PELIGRO : ¡la intoxicación con monóxido de carbono puede resultar en la muerte! Intoxicación con monóxido de carbono: los síntoma s inici ales de la intoxi caci ón con monó xido de carb ono son semej ante s a los de la gripe, con dolor es de cabeza, mareo s y/o náu sea. Si uste d pre sen ta estos sín tom as,[...]
-
Page 32
www .desatech.com 123995-01C 4 6. Siempre haga funcionar el calentador con la perilla de control de la placa en las posiciones jas o ON posiciones. Nunca ponga la perilla de control entre las posiciones de bloqueo. Se podría producir una combustión deciente y niveles más altos de monóxido de carbono. 7. Mantenga limpias y libres de residu[...]
-
Page 33
www .desatech.com 5 123995-01C AIRE P ARA COMBUSTIÓN Y VENTILACIÓN ADVERTEN CIA: esta calentador no se debe instalar en una habi - tación o espacio a menos que se proporcione el volumen adecuado de aire combustión para interiores mediante el método descrito en el Código nacional de gas combusti - ble, ANSI Z223.1/NFP A 54 , el Código interna[...]
-
Page 34
www .desatech.com 123995-01C 6 Ejemplo: 72.49 m 3 (2560 pies 3 ) (volumen del espacio) x 20 = 51,200 (BTU/h máximo que el espacio puede admitir) 3. Agregue la cantidad de BTU/h de todos los aparatos que queman combustible en ese espacio. Calentador sin ventilación _________ BTU/h Calentador de agua a gas* _________ BTU/h Horno de gas _________ BT[...]
-
Page 35
www .desatech.com 7 123995-01C ADVERTENCIA: si el área en la que se va a operar el calenta- dor no cumple los requisitos de volumen de aire de combustión para interiores, se debe pro - porcionar aire de combustión y p a r a v e n ti l a c ió n m ed i a nt e uno de los métodos descritos en el Código nacional de gas combustible, ANSI Z223.1/NFP[...]
-
Page 36
www .desatech.com 123995-01C 8 91.5 cm (36") Mín. 7.7 cm (3") PISO TECHO 20.3 cm (8") 91.5 cm (36") Lado izquierdo Lado derecho Distancias mínimas de los laterales del calentador Distancia mínima a la supercie de la alfombra, azulejo u otro material combustible Figura 4 - Distancias mínimas de montaje vistas desde la part[...]
-
Page 37
www .desatech.com 9 123995-01C INST ALACIÓN Continuación IMPORT ANTE: los calentadores sin ventilación añaden humedad al aire. Aunque esto es bené - co, la instalación del calentador en habitaciones sin suciente aire de ventilación puede ocasionar la formación de moho debido al exceso de hu - medad. Consulte Ai re para combustión y v[...]
-
Page 38
www .desatech.com 123995-01C 10 Métododejaciónavigadepared Para jar el tornillo de montaje a la viga de pared 1. Perfore el oricio en el lugar marcado utili - zando una broca de 9/64". 2. Introduzca el tornillo de montaje en la viga de la pared. 3. Apriete el tornillo hasta dejar un espacio de 1.6 mm (1/16") ([...]
-
Page 39
www .desatech.com 11 123995-01C IMPORT ANTE: para gas natural, verique la presión de la línea de gas antes de conectar el calentador a la misma. La presión de la línea de gas no debe ser de más de 10.5". de agua. Si la presión de la línea de gas es mayor , se pueden producir daños al regulador del calentador . PRECAUCIÓN: para prop[...]
-
Page 40
www .desatech.com 123995-01C 12 T apón T ubo de T tubería Unión Unión T Buje reductor a 1/8" tipo NPT T apón con rosca de 1/8" tipo NPT * Una válvula de cierre de equipo con diseño certicado por la CSA con rosca tipo NPT de 1/8" es una alternativa aceptable como con exi ón para el medid or de pru eba . Adqui era la válvul[...]
-
Page 41
www .desatech.com 13 123995-01C Figura 16 - Revisión de las uniones de gas para propano o gas LP Válvula de cierre del equipo T anque de suministro de propano o gas LP Figura 15 - Revisión de las uniones de gas para gas natural Válvula de cierre del equipo Medidor de gas Ubicación de la válvula de control Ubicación de la válvula de control [...]
-
Page 42
www .desatech.com 123995-01C 14 3. Si va a realizar algún trabajo de mante - nimiento, desconecte el suministro de energía eléctrica al calentador . 4. Gire la perilla de control en dirección de la manecillas del reloj hasta la posición OFF (apagado). 5. Espere cinco minutos a que se disipe el gas. Luego, compruebe que no huela a gas, incluso [...]
-
Page 43
www .desatech.com 15 123995-01C OFF Figura 19 - Piloto Figura 17 - Perilla de control en la posición OFF (apagado) (modelos con control manual) Figura 18 - Perilla de control en la posición OFF (apagado) (modelos con termostato) T Perilla de control Botón de encendido FUNCIONAMIENT O Continuación Botón de encendido Perilla de control Nota: si [...]
-
Page 44
www .desatech.com 123995-01C 16 INSPECCIÓN DEL CALENT ADOR Revise frecuentemente los patrones de la llama del piloto y de la llama del quemador . P A TRÓN DE LA LLAMA DEL PILOT O La gura 21 muestra un patrón correcto de la llama del piloto. La gura 22 muestra un patrón incorrecto de la llama del piloto. La llam a incor recta del piloto no[...]
-
Page 45
www .desatech.com 17 123995-01C A VISO: no confunda las llamas anaranjadas con el color amari- llo en las puntas. El polvo y otras partículas pequeñas se introdu- cen al calentador y al quemarse producen breves manchas de llamas anaranjadas. P A TRÓN DE LA LLAMA DEL CALENT ADOR DE MODELOS LLAMA AzUL En la gura 23 se muestra el patrón correct[...]
-
Page 46
www .desatech.com 123995-01C 18 ADVERTENCIA: si no man- tiene limpias las aberturas pr inc ip ale s de l qu ema do r s e pueden producir hollín y daños a la propiedad. PILOTO CON ODS Y QUEMADOR Utilice una aspiradora, aire a presión o un cepillo de cerdas suaves para la limpieza. ENTRADA DE AIRE AL PILOT O DEL QUEMADOR Los oricios de la entra[...]
-
Page 47
www .desatech.com 19 123995-01C SOL UCIÓN DE PROBLEMAS ADVERTENCIA: apague y desconecte el calentador y deje que se enfríe antes de darle servicio. Sólo una persona de servicio capacitada debe reparar el calentador o darle servicio. P RE CA UC IÓ N: nu nca ut i li ce u n al am b re , a gu ja u o b je to s pa r ec id os pa r a limpiar el piloto/[...]
-
Page 48
www .desatech.com 123995-01C 20 SOL UCIÓN DE PROBLEMAS Continuación CAUSA POSIBLE 1. La peri lla de contro l n o está presionada completamente 2. La perilla de control no se presionó durante el tiempo suciente 3. La válvula de cierre del equipo no está totalmente abierta 4. La conexión del termopar está oja en la válvula de control 5[...]
-
Page 49
www .desatech.com 21 123995-01C SOL UCIÓN DE PROBLEMAS Continuación CAUSA POSIBLE 1. La placa está dañada 2. La presi ón del gas de entra - da es muy baja 3. La perilla de control está colocada entre posiciones predeterminadas 1. No hay suciente aire 2. La presi ón del gas de entra - da es muy baja 3. El regulador de gas está defectuoso [...]
-
Page 50
www .desatech.com 123995-01C 22 SOL UCIÓN DE PROBLEMAS Continuación CAUSA POSIBLE 1. Cuando se calientan, los vap ore s prov eni ent es de los pulido res de muebles, cera, limpiadores de alfombras, etc., pueden convertirse en residuos de polvo blanco 1. No hay suciente aire para combustión o ventilación 1. El calentador está queman - do vap[...]
-
Page 51
www .desatech.com 23 123995-01C ESPECIFICACIONES MODELOS DE LLAMA AzUL GWP6 • 4,400/6,000 Btu/h (variable) • Propano o gas LP • Encendido piezoeléctrico • Aj uste del r eg ul ad or d e pr es ió n - 8" d e c. a. • Pr es ión de l gas de ent rad a* (p ulg . de agua ): Máximo 14" de c.a., Mínimo 1 1" de c.a. GWN6 • 4,400[...]
-
Page 52
www .desatech.com 123995-01C 24 15 25 17 19 1 2 3 5 6 7 8 9 4 12 13 14 15 18 16 17 9 20 21 23 22 24 13 10 1 1 PIEzAS MODELOS GWP6,GWN6,GWP10,GWN10,GWP10T ,GWN10T , MN10T ,MP10T ,VN1000BT A,VP1000BT A,WMN10,WMP10 Piloto 1 1-1 1 1-2[...]
-
Page 53
www .desatech.com 25 123995-01C PIEzAS Esta lista contiene las piezas reemplazables utilizadas en el calentador . Al hacer un pedido de pie - zas, siga las instrucciones enumeradas en Piezas de repuesto en la página 28 de este manual. N° N° DE P ARTE DESCRIPCIÓN CANT . 1 098304-01 T ornillo, #10 x 3/8" • • • • • • 2 2 099467-03[...]
-
Page 54
www .desatech.com 123995-01C 26 PIEzAS MODELOS GWRP10,GWRN10,VP5D,VN6D,VP10A,VN10A,VP10T A,VN10T A A B 1 1 24** 19* * Manual Control Models Only ** Thermostat Control Models Only 18* 16 15 14* 13* 10* 12* 9 9 1 1 20 7 8 8 (VP5D and VN6D Models Only 6 5 4 3 2 1 21* 22 17 17 25** 9 23** Piloto * Sólo para modelos de control manu[...]
-
Page 55
www .desatech.com 27 123995-01C PIEzAS Esta lista contiene las piezas reemplazables utilizadas en el calentador. Al hacer un pedido de piezas, siga las instrucciones enumeradas en Piezas de repuesto en la página 28 de este manual. N° N° DE P ARTE DESCRIPCIÓN CANT . 1 098304-01 T ornillo, #10 x 3/8" • • • • • • • • 2 2 09946[...]
-
Page 56
www .desatech.com 123995-01C 28 ACCESORIO Adquiera estos accesor ios con su distribuidor local. Si no pueden proporcionarle estos accesorios, comuníquese con la Central de piezas más cercana o llame a DESA Hea - ting, LLC al 1-866-672-6040 para obtener información. T ambién puede escribir a la dirección que aparece en la última página de est[...]
-
Page 57
www .desatech.com 29 123995-01C CENTRAL DE PIEzAS Estas Centrales de piezas son empresas privadas. Han aceptado dar asistencia a las nece - sidades de nuestros clientes ofreciendo piezas de repuesto y accesorios originales. Those Heater Guys 255 E. Stowell Street Upland, CA 91786, EE.UU. 909-982-301 1 T ool & Equipment Co. 5 Manila Ave Hamden, [...]
-
Page 58
www .desatech.com 123995-01C 30 _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________________________[...]
-
Page 59
www .desatech.com 31 123995-01C _____________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________________________________[...]
-
Page 60
123995-01 Rev . C 09/08 NOT A UPC DESA Heating, LLC 2701 Industrial Drive Bowling Green, KY 42101 www .desatech.com 1-866-672-6040 123995 01[...]