Desa RN30E-CAN manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Desa RN30E-CAN, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa RN30E-CAN one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Desa RN30E-CAN. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Desa RN30E-CAN should contain:
- informations concerning technical data of Desa RN30E-CAN
- name of the manufacturer and a year of construction of the Desa RN30E-CAN item
- rules of operation, control and maintenance of the Desa RN30E-CAN item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa RN30E-CAN alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa RN30E-CAN, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa RN30E-CAN.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa RN30E-CAN item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    ® WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance.[...]

  • Page 2

    2 105056 BLUE-FLAME VENT -FREE PROP ANE/LP AND NA TURAL GAS GREENHOUSE CO2 GENERA TOR SAFETY INFORMA TION WARNING ICON G 001 WARNINGS IMPORTANT: Read this Owner’s Manual carefully and completely before trying to assemble, operate, or service this appliance. Improper use of this appliance can cause serious injury or death from burns, fire, explosi[...]

  • Page 3

    3 105056 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Vent-Free Propane/LP or Natural Gas Appliance PRODUCT FEA TURES Safety Device This appliance has a pilot with an Oxygen Depletion Sensor Shutoff System (ODS). The ODS/pilot is a required feature for vent- free CO2 generators. The ODS/pilot shuts off the CO2 generator if there is not enoug[...]

  • Page 4

    4 105056 BLUE-FLAME VENT -FREE PROP ANE/LP AND NA TURAL GAS GREENHOUSE CO2 GENERA TOR Continued WARNING: If the area in which the CO2 generator may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction, provide adequate combustion and ventilation air by one of the methods described in [...]

  • Page 5

    5 105056 OWNER’S MANUAL Figure 2 - Ventilation Air From Inside Building If Applicable Or Remove Door into Adjoining Room, Option 3 Ventilation Grills Into Adjoining Room, Option 2 12" 12" Ventilation Grills into Adjoining Room, Option 1 AIR FOR COMBUSTION AND VENTILA TION Continued Outlet Air Inlet Air Figure 3 - Ventilation Air From Ou[...]

  • Page 6

    6 105056 BLUE-FLAME VENT -FREE PROP ANE/LP AND NA TURAL GAS GREENHOUSE CO2 GENERA TOR INSTALLING APPLIANCE TO WALL Mounting Bracket The mounting bracket is located on back panel of appliance. It has been taped there for shipping. Remove mounting bracket from back panel. Figure 5 - Mounting Bracket Location Removing Front Panel Of CO2 Generator 1. R[...]

  • Page 7

    7 105056 OWNER’S MANUAL INST ALLA TION Continued Marking Screw Locations 1. T ape mounting bracket to wall where appliance will be located. Make sure mounting bracket is level. WARNING: Maintain minimum clearances shown in Figure 7. If you can, provide greater clear- ances from floor and joining wall. 2. Mark screw locations on wall (see Fig- ure[...]

  • Page 8

    8 105056 BLUE-FLAME VENT -FREE PROP ANE/LP AND NA TURAL GAS GREENHOUSE CO2 GENERA TOR Figure 13 - Gas Connection * An A.G.A. or G.G.A. design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional A.G.A. or G.G.A. design certified manual shutoff valve from your dealer. See [...]

  • Page 9

    9 105056 OWNER’S MANUAL ON POSITION OFF POSITION INST ALLA TION Continued CHECKING GAS CONNECTIONS WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Cor- rect all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a[...]

  • Page 10

    10 105056 BLUE-FLAME VENT -FREE PROP ANE/LP AND NA TURAL GAS GREENHOUSE CO2 GENERA TOR OFF HIGH PILOT LOW IGNITOR OPERA TING CO2 GENERA TOR FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has [...]

  • Page 11

    11 105056 OWNER’S MANUAL 1/2 HEAT SHIELD HEIGHT INCORRECT FLAME PATTERN AT HIGH POSITION INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 18 shows a correct pilot flame pat- tern. Figure 19 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This[...]

  • Page 12

    12 105056 BLUE-FLAME VENT -FREE PROP ANE/LP AND NA TURAL GAS GREENHOUSE CO2 GENERA TOR TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and unplug appliance and let cool before servicing. Only a quali- fied service person should ser- vice and repair appliance. CAUTION: Never use a wire, needle, or [...]

  • Page 13

    13 105056 OWNER’S MANUAL TROUBLESHOOTING Continued OBSERVED PROBLEM Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial operation Appliance produces a whistling noise when burner is lit POSSIBLE CAUSE 1. Manifold pressure is too low 2. Burner orifice is clogged 1[...]

  • Page 14

    14 105056 BLUE-FLAME VENT -FREE PROP ANE/LP AND NA TURAL GAS GREENHOUSE CO2 GENERA TOR TROUBLESHOOTING Continued WARNING ICON G 001 WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a nei[...]

  • Page 15

    15 105056 OWNER’S MANUAL REPLACEMENT PA R T S Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. Parts Under Warranty Contact authorized dealers of this product. If they can’t supply original replacement part(s) contact DESA International’s Tech- nical Service Department at 1[...]

  • Page 16

    16 105056 BLUE-FLAME VENT -FREE PROP ANE/LP AND NA TURAL GAS GREENHOUSE CO2 GENERA TOR 1 2 4 5 6 6 7 8 8 9 10 11 12 15 17 19 21 22 23 20 26 25 18 14 16 24 3 13 ODS/PILOT 10-1 10-2 ILLUSTRA TED PA R T S BREAKDOWN RP30E-CAN RN30E-CAN[...]

  • Page 17

    17 105056 OWNER’S MANUAL P ARTS LIST RP30E-CAN RN30E-CAN This list contains replaceable parts used in your appliance. When ordering parts, follow the instructions listed under Replacement Parts on page 17 of this manual. KEY PART NO. NUMBER DESCRIPTION QTY. 1 098304-01 Screw, #10 x 3/8" 2 2 098345-01AC Front Panel 1 3 103476-02 Grill Guard 1[...]

  • Page 18

    KEEP THIS WARRANTY W ARRANTY INFORMA TION Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. Model Serial No. Date Purchased LIMITED [...]