Go to page of
Similar user manuals
-
Stove
Desa S26PTA
28 pages 1.65 mb -
Stove
Desa FSVYD18P
34 pages 0.67 mb -
Stove
Desa SVYD18NRA/PRA SERIES
28 pages 0.54 mb -
Stove
Desa S39PT
26 pages 0.81 mb -
Stove
Desa (F)SVYD18N
34 pages 0.68 mb -
Stove
Desa 107434-01C.pdf
28 pages 3.42 mb -
Stove
Desa (F)SVYD18NR
34 pages 0.68 mb -
Stove
Desa S26NT
24 pages 0.94 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Desa S26PTA, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa S26PTA one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Desa S26PTA. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Desa S26PTA should contain:
- informations concerning technical data of Desa S26PTA
- name of the manufacturer and a year of construction of the Desa S26PTA item
- rules of operation, control and maintenance of the Desa S26PTA item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa S26PTA alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa S26PTA, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa S26PTA.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa S26PTA item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- ?[...]
-
Page 2
www .desatech.com 1 10361-01G 2 SAFETY INFORMA TION T ABLE OF CONTENTS Safety Information ............................................... 2 Product Identication ........................................... 4 Local Codes......................................................... 5 Unpacking............................................................[...]
-
Page 3
www .desatech.com 1 10361-01G 3 - kno wn to the stat e of Calif orn ia [...]
-
Page 4
www .desatech.com 1 10361-01G 4 SAFETY INFORMA TION Continued 1. This ap pli anc e i s on ly for us e w ith the ty pe of ga s indi cate d on the ra ti ng pl at e. Thi s app li an ce is n ot con ver tibl e f or use wit h o the r g ases . 2. Do not place propane/LP supply tank(s) in - side any str uct ure. Loc ate pro pane /LP supp ly tank (s) ou tdo[...]
-
Page 5
www .desatech.com 1 10361-01G 5 LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the lat - est edition of The National Fuel Gas Code, ANSI Z223.1/NFP A 54 *. *A vailable from: American National Standards Institute, Inc. 1430 Broadway New Y ork, NY 10018 National Fire Protection Association, In[...]
-
Page 6
www .desatech.com 1 10361-01G 6 construction where: - [...]
-
Page 7
www .desatech.com 1 10361-01G 7 If the actual Btu/Hr used is less than the maximum Btu/Hr the space can support, the space is an un- conn ed space . Y o u will n eed no ad dition al fres h air ventilation. W ARNING: If the area in - ?[...]
-
Page 8
www .desatech.com 1 10361-01G 8 6" Minimum 48" Minimum Ceiling Floor Back Wall Corner Wall Wall 6 " Minimum 6 " Minimum 12" Minimum 12" Minimum 48" Minimum Ceiling Side Wall Side Wall W ARNING: Never install the heater • in a recreat[...]
-
Page 9
www .desatech.com 1 10361-01G 9 - ?[...]
-
Page 10
www .desatech.com 1 10361-01G 10 W e recommend that you install a sediment trap in supply line as[...]
-
Page 11
www .desatech.com 1 10361-01G 1 1 INST ALLING LOGS [...]
-
Page 12
www .desatech.com 1 10361-01G 12 INST ALLA TION Continued IMPORT ANT : Make sure log does not cover any burner ports (see Figure 12). Figure 12 - Installing One-Piece Log set (T op V iew) One Piece Log Set Burner Ports T ools required: Phillips[...]
-
Page 13
www .desatech.com 1 10361-01G 13 INST ALLA TION Continued Figure 16 - Removing Blower Brackets from Stove and Attaching to Blower Blower Blower Bracket Firebox T op 12 . Using the four screws previously removed, mount blower assembly to stove by reat - taching blower brackets to rear panel (see Figure 16). Tighten screws securely. 13. Inst all plas[...]
-
Page 14
www .desatech.com 1 10361-01G 14 OPERA TING HEA TER FOR YOUR SAFETY W ARNING: If you do not fol- low these instructions exactly , ?[...]
-
Page 15
www .desatech.com 1 10361-01G 15 Figure 20 - Pilot Thermocouple Pilot Burner Ignitor Electrode OPERA TING HEA TER Continued INSPECTING B URNERS Check pilot ame pattern and burner ame pat - terns often. Fi gu re 21 sho ws a co rr ec t pi lo t am e pa tt er n. Fig ur e 22 show s an [...]
-
Page 16
www .desatech.com 1 10361-01G 16 CLEANING AND MAINTENANCE W ARNING: T urn off heater -[...]
-
Page 17
www .desatech.com 1 10361-01G 17 Use a vacuum cleaner or pressurized air to clean. Exterior Use a soft cloth dampened with a mild soap and water mixture. W ipe the cabinet to remove dust. LOGS • If you remove logs for cleaning, refer to Install- ing Logs, page 1 1, to properly re[...]
-
Page 18
www .desatech.com 1 10361-01G 18 TROUBLESHOO TING [...]
-
Page 19
www .desatech.com 1 10361-01G 19 TROUBLESHOO TING Continued 1. C o nt ro l kn o b no t fu ll y p r e ss ed i n 2. Control knob not pressed in long enough 3. Equipment shutoff valve not fully open 4. Pilot ame not touching ther - mocouple, which allows ther - mocouple to cool, causing pilot flame to go o[...]
-
Page 20
www .desatech.com 1 10361-01G 20 TROUBLESHOO TING Continued 1. Turning control knob to HI position when burner is cold 2. Air in gas line 3. Air passageways on heater blocked 4 . Dirty or partially clogged burner orice 1. Improper log placement 2. Drafts or other air currents affecting ame pattern 3.[...]
-
Page 21
www .desatech.com 1 10361-01G 21 • [...]
-
Page 22
www .desatech.com 1 10361-01G 22 ILL USTRA TED P ARTS BREAKDOWN 9 3 2 6 5 8 4 1 12 13 1 1 10 9 7 14[...]
-
Page 23
www .desatech.com 1 10361-01G 23 P ARTS LIST This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. 1 105441-01 Log Set • • 1 2 104286-01 ODS [...]
-
Page 24
www .desatech.com 1 10361-01G 24 ILL USTRA TED P ARTS BREAKDOWN 1 4 14 3 2 14 7 16 15 1 1 18 10 13 5 6 9 8 17 12[...]
-
Page 25
www .desatech.com 1 10361-01G 25 P ARTS LIST This list contains replaceable parts used in your heater . When ordering parts, follow the instructions listed under Replacement Parts on page 26 of this manual. [...]
-
Page 26
www .desatech.com 1 10361-01G 26 REPLACEMENT P ARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty . Cont act autho riz ed dea ler s of this produ ct. If they ca n’ t sup ply ori gina l rep lace me nt part (s) ca l[...]
-
Page 27
www .desatech.com 1 10361-01G 27 P ARTS CENTRAL These Parts Centrals are privately owned businesses. They have agreed to support our customer ’ s needs by providing original replacement parts and accessories. 5 Manila A ve Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Depa[...]
-
Page 28
110361 01 2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com LIMITED WARRANTY VENT -FREE GAS PEDEST AL ST O VE DESA Heating Products warrants this product to be free from defects in materials and components for two (2) years from the date of rst purchase, provided that the product has been properly installed, op[...]