Go to page of
Similar user manuals
-
Indoor Fireplace
Desa TPNA-A(-HA)
36 pages 2.49 mb -
Indoor Fireplace
Desa LZPR)
44 pages 2.76 mb -
Indoor Fireplace
Desa GA6053
8 pages 0.65 mb -
Indoor Fireplace
Desa CHDV36NRA
40 pages 2.49 mb -
Indoor Fireplace
Desa V42EN-A
38 pages 4.53 mb -
Indoor Fireplace
Desa VGL450N
16 pages 0.67 mb -
Indoor Fireplace
Desa LFP33PR
30 pages 0.86 mb -
Indoor Fireplace
Desa (V)G36
16 pages 1.39 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Desa (V)368ST, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa (V)368ST one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Desa (V)368ST. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Desa (V)368ST should contain:
- informations concerning technical data of Desa (V)368ST
- name of the manufacturer and a year of construction of the Desa (V)368ST item
- rules of operation, control and maintenance of the Desa (V)368ST item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa (V)368ST alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa (V)368ST, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa (V)368ST.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa (V)368ST item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
For more information, visit www .desatech.com SA VE THIS BOOK This book is valuable. In addition to instructing you on how to install and maintain your appliance, it also contains information that will enable you to obtain re- placement parts or accessory items when needed. Keep it with your other important papers. [...]
-
Page 2
www .desatech.com 5551 1E 2 - ?[...]
-
Page 3
www .desatech.com 5551 1E 3 SAFETY Continued ?[...]
-
Page 4
www .desatech.com 5551 1E 4 FIREBO X INST ALLA TION Figure 2 - Common Location of Fireplace Back and sides of rebox 1" min. Adjacent wall 12" min. Chimney outer pipe surfaces 2" min. Bottom of rebox to oor 0" min. ?[...]
-
Page 5
www .desatech.com 5551 1E 5 12 3 / 8 " Dia. (31.4 cm) Outer Pipe 2" (5.1 cm) Min. Clearance From Outer Pipes to Combustibles 1" (2.5 cm) Min. T o Combustibles 21 5 / 16 " (54 cm) 42 5 / 8 " (108 cm) 24" (61 cm) 12" (31 cm) Figure 6 - Framing Clearances Figure 7 - Framing Firebox with “Z” T ype Ember Protectors[...]
-
Page 6
www .desatech.com 5551 1E 6 FIREBO X INST ALLA TION Continued VENTING INST ALLA TION The installation of an outside air kit should be per - formed during the rough framing of the rebox due to the nature of it’s location. Outside combustion air is accessed through and ext[...]
-
Page 7
www .desatech.com 5551 1E 7 Figure 13 - Pipe Connection GAIN 368STM See-Through 66 1 / 4 " V368ST See-Through 54 " (V)12-8DM Flue Pipe 10 5 / 8 " (V)18-8DM Flue Pipe 16 5 / 8 " (V)24-8DM Flue Pipe 23 5 / 8 " (V)36-8DM Flue Pipe 34 [...]
-
Page 8
www .desatech.com 5551 1E 8 2" (5.1cm) Minimum VENTING INST ALLA TION Continued Figure 17 - Chimney Supports Straps OFFSET RISE A B 48" 18" 12" 4 3 / 8 " 16 3 / 8 " 9 1 / 2 " 25 1 / 4 " 1 12 1 / 2 " 30 3 / 8 " 1 14 3 / 8 " 34" 2 17 5 / 8[...]
-
Page 9
www .desatech.com 5551 1E 9 TYPICAL OFFSET INST ALLATIONS OFFSET ELBOW OFFSET ELBOW RETURN ELBOW OFFSET ELBOW RETURN ELBOW RETURN ELBOW RETURN ELBOW CEILING SUPPORT PIPE V12S-8DM 6' MAX (15.2cm) 6' MAX (15.2cm) 6' MAX (15.2cm) 6' MAX (15.2cm) 6' MAX (15.2cm) 6' MAX (15.2cm) MINIMUM HEIGHT 15 FT . (4.5m) MAXIMUM HEIGHT [...]
-
Page 10
www .desatech.com 5551 1E 10 VENTING INST ALLA TION Continued Nail Only Outer Perimeter of Flashing Storm Collar Flashing Cone Underlap Shingles at Bottom Overlap Shingles T op and Sides Only Figure 23 - Flashing Installation T o mai nt ain a 1" cle ara n ce to p ip e on a ro o f wi th a pitch,[...]
-
Page 11
www .desatech.com 5551 1E 11 Secure T ermination to Outer Pipe with 3 Screws RTL-8DM Stainless Inner Flue Pipe Apply W aterproof Caulking Storm Collar Flashing Underlap Shingles Figure 25 - T erminations Overlap Shingles (T op and Sides of Flashing Base) VENTING INST ALLA TION Continued In[...]
-
Page 12
www .desatech.com 5551 1E 12 Figure 28 - Gas Line Knockout Side Firebrick Finished Side Refractory Knockout Plug Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1/2" Dowel Remove Knockout - vice person must connect gas supply . Follow all local cod[...]
-
Page 13
www .desatech.com 5551 1E 13 Figure 31 - Bi-Fold Glass Doors Doors Fully Closed Firebox Front Firebox Front Doors Fully Opened OPERA TION AND MAINTENANCE GUIDELINES - ate an unvented gas log set in ?[...]
-
Page 14
www .desatech.com 5551 1E 14 OPERA TION AND MAINTENANCE GUIDELINES Continued C l e a n g l a s s w i t h a n y c o m m e r c i a l g l a s s cleaner or soap and water. Do not use any abrasive material to clean glass. Do not clean glass with any cool water if glass is still hot from the re. T o remove do[...]
-
Page 15
www .desatech.com 5551 1E 15 Black - GA650, 01244 [...]
-
Page 16
5551 1 Rev . E 06/08 NOT A UPC REPLACEMENT AND A CCESSOR Y P ARTS Continued DESA Heating, LLC 2701 Industrial Drive Bo[...]