Go to page of
Similar user manuals
-
Indoor Fireplace
Desa EFS26PRA
40 pages 0.85 mb -
Indoor Fireplace
Desa (V)T32EP SERIES
40 pages 2.03 mb -
Indoor Fireplace
Desa VCBK4R
2 pages 0.33 mb -
Indoor Fireplace
Desa W26RO
4 pages 0.67 mb -
Indoor Fireplace
Desa (V)CB36N(E)
36 pages 2.69 mb -
Indoor Fireplace
Desa VF-18P-PDG,VF-24N-PDG, VF-24P-PDG, VF-18NPDG, VF-24N-BTB, VF-18N-BTB, VF-24P-BTB, VF-18P-BTB
31 pages 3.5 mb -
Indoor Fireplace
Desa TPNEA-A
36 pages 2.49 mb -
Indoor Fireplace
Desa GA3700
36 pages 1.62 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Desa VM42, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Desa VM42 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Desa VM42. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Desa VM42 should contain:
- informations concerning technical data of Desa VM42
- name of the manufacturer and a year of construction of the Desa VM42 item
- rules of operation, control and maintenance of the Desa VM42 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Desa VM42 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Desa VM42, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Desa service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Desa VM42.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Desa VM42 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
MODELS M36(B,H), M42(B,H), VM36(B,H), AND VM42(B,H) NA TURAL GAS This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifie[...]
-
Page 2
108795-01E 2 For more information, visit www.desatech.com For more information, visit www.desatech.com TABLE OF CONTENTS SAFETY INFORMA TION ............................................................ 2 UNP ACKING ............................................................................... 3 INTRODUCTION ........................................[...]
-
Page 3
108795-01E 3 3 For more information, visit www.desatech.com For more information, visit www.desatech.com SAFETY INFORMATION UNPACKING 8. T urn fireplace off and let cool before servicing or repairing. Only a qualified service person should install, service, or re- pair this fireplace. Have fireplace inspected annually by a quali- fied service perso[...]
-
Page 4
108795-01E 4 For more information, visit www.desatech.com For more information, visit www.desatech.com GAS RATING - NATURAL M36(B,H)/VM36(B,H) M42(B,H)/VM42(B,H) Max. Input Rating: 40,000 Btu/Hr 45,000 Btu/Hr Manifold Pressure: 3.5 in. WC (.87 kPa) 3.5 in. WC (.87 kPa) Minimum Supply Pressure: 4.5 in. WC (1.12 kPa) 4.5 in. WC (1.12 kPa) Maximum Sup[...]
-
Page 5
108795-01E 5 5 For more information, visit www.desatech.com For more information, visit www.desatech.com PRODUCT SPECIFICATIONS S T P Q R X Outside Air Kit Location (Optional) K 7" J I M L P V 13.5" S 1.5" Glass Door (Optional) W T O N Alternate Gas Supply Inlet 7" G H F A Stand Off Collar For Use With 6"Ø Type B-1 Vent Pi[...]
-
Page 6
108795-01E 6 For more information, visit www.desatech.com For more information, visit www.desatech.com CLEARANCES Minimum clearances to combustibles are: • Back and Sides of Outer Surround ............................ 0" min. • Drywall to Sides of Front Face (Nailing Flanges) ... 0" min. • “B” V ent Surfaces ....................[...]
-
Page 7
108795-01E 7 7 For more information, visit www.desatech.com For more information, visit www.desatech.com MANTEL CLEARANCES AND WALL DETAILS A combustible mantle shelf maybe installed a maximum 12 " (229mm) from the wall. Figures 5 and 6 show the minimum allowable distances from various combustible mantle components in relation to the fire- pla[...]
-
Page 8
108795-01E 8 For more information, visit www.desatech.com For more information, visit www.desatech.com PRE-INST ALLA TION PREP ARA TION Continued INSTALLING TRANSITION PIPE AND STARTER COLLAR The transition pipe and starter collar shown in Figure 9 are supplied with the fireplace, unattached and ready for installation. Remove the starter collar and[...]
-
Page 9
108795-01E 9 9 For more information, visit www.desatech.com For more information, visit www.desatech.com VENTING INST ALLA TION A B-type venting system must be connected to the appliance for venting to the outside of the building. The following section is provided as a guide to a standard B-type vent installation. Standing codes requirements concer[...]
-
Page 10
108795-01E 10 For more information, visit www.desatech.com For more information, visit www.desatech.com CHECKING FOR PROPER VENTING After completing and checking the electrical, gas and vent connec- tions, follow the lighting instructions and allow the main burner to run for approximately 5 minutes. Hold a lighted match or cigarette near the top ed[...]
-
Page 11
108795-01E 11 11 For more information, visit www.desatech.com For more information, visit www.desatech.com Figure 14 - Wall Switch Wiring Diagram Note: If any of the original wire as supplied must be replaced, use 18 AWG TYPE CL2 (UL) 105 C (25 ft. length MAXIMUM) or equivalent. OPTIONAL WIRELESS HAND-HELD REMOTE CONTROL INSTALLATION Note: If using[...]
-
Page 12
108795-01E 12 For more information, visit www.desatech.com For more information, visit www.desatech.com Installing 9-Volt Battery in Hand-Held Remote Control Unit 1. Remove battery cover on back of remote control unit. 2. Attach terminal wires to the battery (not included). Place bat- tery into the battery housing. Note: Only use alkaline battery .[...]
-
Page 13
108795-01E 13 13 For more information, visit www.desatech.com For more information, visit www.desatech.com P I L O T ON OFF IN OUT EMBER AND PAN MATERIAL PLACEMENT 1. Open the bag(s) of vermiculite and fill the entire burner pan until the burner tube is completely covered (see Figure 22). 2. Smooth the pan material just even with edges of the burne[...]
-
Page 14
108795-01E 14 For more information, visit www.desatech.com For more information, visit www.desatech.com LOG PLACEMENT FOR M36/VM36 MODELS 1. Place small front right log (log 1) on right front of grate as shown in Figure 25. 2. Place large back log (log 2) onto grate making sure notches rest over grate as shown in Figure 25. 3. Place log 3 across lo[...]
-
Page 15
108795-01E 15 15 For more information, visit www.desatech.com For more information, visit www.desatech.com INST ALLA TION Continued LOG PLACEMENT FOR M42/VM42 MODELS 1. Place log 1A on the front left side of grate. Place log 1B on the front right side of the grate. See Figure 29. 2. Place large back log (log 2) onto grate making sure notches rest o[...]
-
Page 16
108795-01E 16 For more information, visit www.desatech.com For more information, visit www.desatech.com COMBUSTION AIR KIT MODEL AK4 (OPTIONAL) The outside air kit may be installed on the left side of the fireplace only. The vent can be installed through the outside wall or a ventilated crawl space. The handle to operate the damper door for the out[...]
-
Page 17
108795-01E 17 17 For more information, visit www.desatech.com For more information, visit www.desatech.com 5. Once the top and bottom pins are secured, unfold the door into the closed position. 6. Repeat the process for the opposite door assembly . 7. T o adjust the doors, slide them partially open. Using a screw- driver , loosen the hold-down scre[...]
-
Page 18
108795-01E 18 For more information, visit www.desatech.com For more information, visit www.desatech.com P I L O T ON OFF IN OUT IN Figure 39 - Control Knob in the PILOT position Position Indicator Gas Control Knob TO TURN OFF GAS TO APPLIANCE 1. T urn off the wall switch. 2. T urn off all electric power to the appliance if service is to be perf orm[...]
-
Page 19
108795-01E 19 19 For more information, visit www.desatech.com For more information, visit www.desatech.com Thermopile Pilot Burner Ignitor OPTIONAL HAND-HELD REMOTE OPERATION Note: The receiver and hand-held remote control kit m ust be purchased separately (see Accessories, page 27 ). Follow installa- tion instructions on pages 11 and 12 of this ma[...]
-
Page 20
108795-01E 20 For more information, visit www.desatech.com For more information, visit www.desatech.com TECHNICAL SER VICE You may have further questions about installation, operation, or troubleshooting. If so, contact DESA International’s Technical Ser- vice Department at 1-866-672-6040. When calling please have your model and serial numbers of[...]
-
Page 21
108795-01E 21 21 For more information, visit www.desatech.com For more information, visit www.desatech.com TROUBLESHOOTING The two most common causes of a malfunctioning gas appliance are: 1. Loose wiring connections 2. Construction debris clogging the pilot and/or gas control valve filter OBSERVED PROBLEM Pilot will not light Pilot will not stay l[...]
-
Page 22
108795-01E 22 For more information, visit www.desatech.com For more information, visit www.desatech.com OBSERVED PROBLEM Pilot goes out when wall switch is ON Spark ignitor will not light pilot after re- peated triggering of red button POSSIBLE CAUSE 1. Millivolt output on thermopile too high 1. Defective ignitor (no spark at electrode) 2. Defectiv[...]
-
Page 23
108795-01E 23 23 For more information, visit www.desatech.com For more information, visit www.desatech.com TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a ne[...]
-
Page 24
108795-01E 24 For more information, visit www.desatech.com For more information, visit www.desatech.com ILLUSTRA TED P ARTS BREAKDOWN M36(B,H), M42(B,H), VM36(B,H) AND VM42(B,H) MODELS 51 21 3 25 2 1 10 11 6 57 57 22 50 18 9 8 17 52 13 61 14 45 43 48 59/60 62 44 4 40 39 41 42 56 23 7 46 19 47 7 47 54 55 5 17 16 12 15 52 33 31 28 32 27 11 24 49 58 3[...]
-
Page 25
108795-01E 25 25 For more information, visit www.desatech.com For more information, visit www.desatech.com KEY M36(B,H) M42(B,H) NO. VM36(B,H) VM42(B,H) DESCRIPTION QTY. 1 14574 106543-01 Limit Switch 1 2 106638-01 107797-01 Insulation Pan 1 3 106639-01 107798-01 Fireplace Top Assembly 1 4 106641-01 107800-01 Fireplace Surround 1 5 106642-01 106642[...]
-
Page 26
108795-01E 26 For more information, visit www.desatech.com For more information, visit www.desatech.com ILLUSTRA TED P ARTS BREAKDOWN LOGS FOR M36(B,H), M42(B,H), VM36(B,H) AND VM42(B,H) MODELS Logset for M36(B, H)/VM36(B, H) Models Logset for M42(B, H)/VM42(B, H) Models KEY PART NO. NUMBER DESCRIPTION QTY. - 107999-01 Log Set 1 108724-01 Right Fro[...]
-
Page 27
108795-01E 27 27 For more information, visit www.desatech.com For more information, visit www.desatech.com ACCESSORIES AIR KIT AK4 - Optional kit helps offset the negative pressure often existing in today's tightly constructed homes. REMOTE CONTROL KITS RC - Standard On/Off Millivolt Remote Control Kit GHRC - Hand-Held Remote Control Kit GWMT1[...]
-
Page 28
108795-01E 28 For more information, visit www.desatech.com For more information, visit www.desatech.com LIMITED WARRANTY B-VENT FIREPLACE DESA International warrants this product to be free from defects in materials and components for four (4) years from the date of first purchase, provided that the product has been properly installed, operated and[...]