DeVillbiss Air Power Company MG2-OFTANK-4A manual
- Read online or download the manual
- 12 pages
- 0.14 mb
Go to page of
Similar user manuals
-
Air Compressor
DeVillbiss Air Power Company D26675
14 pages 0.16 mb -
Air Compressor
DeVillbiss Air Power Company LM7580V2C
28 pages 0.21 mb -
Air Compressor
DeVillbiss Air Power Company MGAT-1
12 pages 0.24 mb -
Air Compressor
DeVillbiss Air Power Company 102D-1
16 pages 0.32 mb -
Air Compressor
DeVillbiss Air Power Company 38301-9615
12 pages 0.14 mb -
Air Compressor
DeVillbiss Air Power Company MG1-UMCCOMP-3
12 pages 0.12 mb -
Air Compressor
DeVillbiss Air Power Company 919.19007
8 pages 0.15 mb -
Air Compressor
DeVillbiss Air Power Company Companion 919.19007
8 pages 0.16 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of DeVillbiss Air Power Company MG2-OFTANK-4A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of DeVillbiss Air Power Company MG2-OFTANK-4A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of DeVillbiss Air Power Company MG2-OFTANK-4A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of DeVillbiss Air Power Company MG2-OFTANK-4A should contain:
- informations concerning technical data of DeVillbiss Air Power Company MG2-OFTANK-4A
- name of the manufacturer and a year of construction of the DeVillbiss Air Power Company MG2-OFTANK-4A item
- rules of operation, control and maintenance of the DeVillbiss Air Power Company MG2-OFTANK-4A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of DeVillbiss Air Power Company MG2-OFTANK-4A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of DeVillbiss Air Power Company MG2-OFTANK-4A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the DeVillbiss Air Power Company service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of DeVillbiss Air Power Company MG2-OFTANK-4A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the DeVillbiss Air Power Company MG2-OFTANK-4A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615 MG2-OFTANK-4A REV. 9/23/99 SAFETY GUIDELINES ...................................................... 1 WARRANTY STATEMENT .............................................. 2 WARNING CHART ........................................................ 3-4 GLOSSARY ................[...]
-
Page 2
2 — ENG LIMITED WARRANTY ONE YEAR FROM DA TE OF PURCHASE All merchandise manufactured by DeVilbiss Air Power Company/ExCell Manufacturing is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user). Products covered under this warranty include:[...]
-
Page 3
3 — ENG RISK OF BURSTING RISK OF EXPLOSION OR FIRE RISK OF ELECTRICAL SHOCK AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT IN A VIOLENT TANK EXPLOSION: 1. FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK, CAUSING RUST AND THINNING OF THE STEEL TANK. 2. MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK. 3. [...]
-
Page 4
4 — ENG HAZARD RISK OF ELECTRICAL SHOCK (cont’d) RISK FROM FLYING OBJECTS RISK TO BREATHING RISK OF FALLING RISK FROM MOVING PARTS RISK OF BURNS WHAT CAN HAPPEN REPAIRS ATTEMPTED BY UNQUALIFIED PERSONNEL CAN RESULT IN SERIOUS INJURY OR DEATH BY ELECTROCUTION. ELECTRICAL GROUNDING: FAILURE TO PROVIDE ADEQUATE GROUNDING TO THIS PRODUCT COULD RESU[...]
-
Page 5
5 — ENG DAMAGE: Each air compressor outfit is carefully tested and checked before shipment. With improper handling, damage may result in transit and cause problems in compressor opera- tion. Immediately upon arrival, check equipment for both concealed and visible damages to avoid expenses being incurred to correct such problems. This should be do[...]
-
Page 6
6 — ENG Drain Valve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. Motor Thermal Overload Protector: The electric motor has an automatic thermal overload protector. If the motor over- heats for any reason, the thermal overload protector will shut off the motor. The motor must be a[...]
-
Page 7
7 — ENG Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air filter must be kept clear of obstructions which could reduce air flow to the air compressor. The air compres- sor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. [...]
-
Page 8
8 — ENG Additional Regulators and Controls Since the air tank pressure is usually greater than that which is needed, a separate regulator is usually employed to control the air pressure ahead of any individual air driven device. Break-in Procedures Serious damage may result if the following break- in instructions are not closely followed. This pr[...]
-
Page 9
9 — ENG WATER WILL CONDENSE IN THE AIR TANK. IF NOT DRAINED, WATER WILL CORRODE AND WEAKEN THE AIR TANK CAUSING A RISK OF AIR TANK RUP- TURE. 1 1. After the water has been drained, close the drain cock or drain valve. The air compressor can now be stored. NOTE If drain cock valve is plugged, release all air pressure. The valve can then be removed[...]
-
Page 10
10 — ENG PROBLEM CAUSE Move the pressure switch lever to the “OFF” position. If the outfit doesn’t shut off, unplug. If the electrical contacts are welded together, replace the pressure switch. Contact an authorized service center to check and replace pressure switch. Tighten fittings where air can be heard escaping. Check fittings with soa[...]
-
Page 11
11 — ENG PROBLEM CAUSE CORRECTION Prolonged excessive use of air. Compressor is not large enough for air requirement. Restricted air intake filter. Hole in hose. Check valve restricted. Air leaks. Motor overload protection switch has tripped. Tank pressure exceeds pressure switch “cut-in” pressure. Wrong gauge wire or length of exten- sion co[...]
-
Page 12
DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615 GENERAL MANUAL FOR PERMANENTL Y LUBRICA TED POR T ABLE/ST A TIONAR Y AIR COMPRESSOR SERVICE NOTES[...]