Dimension One Spas Dynamic Massage Sequencer manual
- Read online or download the manual
- 40 pages
- 8.58 mb
Go to page of
Similar user manuals
-
Hot Tub
Dimension One Spas Seville
2 pages 0.22 mb -
Hot Tub
Dimension One Spas AquaPro 19
1 pages 0.03 mb -
Hot Tub
Dimension One Spas Cove
28 pages 6.49 mb -
Hot Tub
Dimension One Spas Home Hot Tubs
36 pages 1.43 mb -
Hot Tub
Dimension One Spas Sarena Bay
56 pages 16.24 mb -
Hot Tub
Dimension One Spas Triad II
2 pages 0.49 mb -
Hot Tub
Dimension One Spas Amore Bay
2 pages 0.1 mb -
Hot Tub
Dimension One Spas Aurora HP
2 pages 0.16 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Dimension One Spas Dynamic Massage Sequencer, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dimension One Spas Dynamic Massage Sequencer one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Dimension One Spas Dynamic Massage Sequencer. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Dimension One Spas Dynamic Massage Sequencer should contain:
- informations concerning technical data of Dimension One Spas Dynamic Massage Sequencer
- name of the manufacturer and a year of construction of the Dimension One Spas Dynamic Massage Sequencer item
- rules of operation, control and maintenance of the Dimension One Spas Dynamic Massage Sequencer item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dimension One Spas Dynamic Massage Sequencer alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dimension One Spas Dynamic Massage Sequencer, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dimension One Spas service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dimension One Spas Dynamic Massage Sequencer.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Dimension One Spas Dynamic Massage Sequencer item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
i[...]
-
Page 2
2002 Dimensi on One Spas Export Ow ner ’s Manual ii[...]
-
Page 3
2002 Dimensi on One Spas Export Ow ner ’s Manual Table of Contents IMPORTANT SAFETY INSTRUCTIONS .................................................................................................. .1 HYPERTHERMIA................................................................................................................... .................... [...]
-
Page 4
2002 Dimensi on One Spas Export Ow ner ’s Manual Using the Scrolling Message Center ............................................................................................. .......................................................... 16 Setting the Time ...........................................................................................[...]
-
Page 5
2002 Dimensi on One Spas Export Ow ner ’s Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL IN STRU CTIONS CAREFULLY When install ing and using this equipment, basi c safety precautions should always b e followed, including: Danger Risk of Accidental Drowning . Extreme caution m ust be exercised to prevent unauthori zed access by children.[...]
-
Page 6
2002 Dimensi on One Spas Export Ow ner ’s Manual Warning To Reduce the Risk of Injury: The use of alcohol, drugs, or medi cation be fore or duri ng spa use may lead to unconsciousness with the possibility of drowning. Warning To Reduce the Risk of Injury: Persons suffering from obesity or with a medical history of heart disease, low or high blood[...]
-
Page 7
2002 Dimensi on One Spas Export Ow ner ’s Manual Caution Observe a reasonable time limit when us ing the sp a. Long exposures at higher temperatures can cause high body temperature. S y mpto ms may incl ude dizzi n ess, nausea , fainting, drowsiness, and reduced awareness. These effects cou ld result in possible drowning. Caution Do not use the s[...]
-
Page 8
2002 Dimensi on One Spas Export Ow ner ’s Manual Warning Signs Each spa has been provided wit h a Warn ing Sign and an Important Notice label. This label outlines safety prec autions. This sign sho uld be permanen tly placed in a location that is visibl e to the spa user. Replacement signs ca n be obta ined from: Dimension One Spas 2611 Business [...]
-
Page 9
2002 Dimensi on One Spas Export Ow ner ’s Manual Hot Tub Features Congratulations! You have purchased one of the f inest port able hot t u bs availab le. Take the time to read these instructions carefu lly . If installed and maintai ned proper ly your hot tub wi ll prov ide many years of enjoyable , trouble-free operation. Read all of th e ins tr[...]
-
Page 10
2002 Dimensi on One Spas Export Ow ner ’s Manual NeckFlex Jet Pillow The NeckFlex Jet Pillow, Figure 2, off ers five height adju stable positions to accommodate different body sizes. The standard mini directional jets can be in terchanged wit h rota ti ng jets and are adjustable for water volu me. See your local Authorized Dimensio n One Spas for[...]
-
Page 11
2002 Dimensi on One Spas Export Ow ner ’s Manual Operation Operation is divided into two sections : Programmi ng t he Digital Control for the Arena , Aurora HP, Ca liente, and Triad (following section) and Programming the Scroll ing Message Center for the Aurora II, Aurora XLT, Calie nte HP, Californian, Chairma n, Chairman II, Diploma t, Nautlil[...]
-
Page 12
2002 Dimensi on One Spas Export Ow ner ’s Manual Control Function 3 3. LIGHT Pad and Status Light Push the LIGHT p ad once to activate the brightest setti n g (S tatus Light will illumi nate, 1). A second push w ill activate the medium setting and a third push w ill ac tivate the di mmest setting. Push the LIGHT pad a fourth time to t urn of f t [...]
-
Page 13
2002 Dimensi on One Spas Export Ow ner ’s Manual Digital Display Messages The following messages may appear in the Digita l Display: “OH” – Overheat Protec tion When “OH” is displayed on the control system Digi tal Dis p lay, the hot tub is in a high temperat ure condition. If such a condition exists, check water temperature and if it i[...]
-
Page 14
2002 Dimensi on One Spas Export Ow ner ’s Manual Using the Programmable Digital Controller To initiate the programming sequenc e at any time, push and hold t he Pro gram Pad for 3 seconds. If, within 10 seconds, you do not proceed with the ho t t ub programmin g, the hot tub will auto mat ically exit the pro gramming sequence and revert to the pr[...]
-
Page 15
2002 Dimensi on One Spas Export Ow ner ’s Manual Temperature Unit Selection To select temperature units p ush t he U p or Down Pads to toggle between ° F (degrees Fahrenheit) or ° C (degrees Celsius). Once the desired temperature unit is selected push the Program Pa d to exi t the programming mode. Note The time of day can be viewed by pushi ng[...]
-
Page 16
2002 Dimensi on One Spas Export Ow ner ’s Manual Top Side Control Control Function 1 1. Digital Display (LCD) The Digital Display continuously shows the operat ing sta tus of the hot tub, as well as the various monitorin g func tions, self-diagnostics , and programming information. 2 JETS 1 and 2 Pads (1) When either JETS pad is pushed, the corre[...]
-
Page 17
2002 Dimensi on One Spas Export Ow ner ’s Manual Control Function 5 5. ENTER Pad This pad is used to exit any programming se quence at any time. 6 6. PROGRAM Pad This pad is used to initiate t h e tim e setting, filter program mi ng, and o ther programming features. For more informat io n, see the next section, “Programming the Scrolling Messag[...]
-
Page 18
2002 Dimensi on One Spas Export Ow ner ’s Manual Clean Filters On alternating months, t he top line of your Digital Disp lay will read, “DIRTY FILTER” and the message “REMO V E FILTERS & CLEAN IN SOLUTION... PUSH AND HOLD ICON PAD MORE THAN 3 SECONDS TO RESET THIS MESSAGE” will scroll from ri ght to left on the botto m li ne of the di[...]
-
Page 19
2002 Dimensi on One Spas Export Ow ner ’s Manual Ice When “ICE CONDITION” and the water temperature a re displayed on the Digital D isplay, the air temperature in the equipment can has gone below a factory-preset level , and the system has activated “Smart Winter Mode.” It will then automatically act iva te the pump(s) to circulate water.[...]
-
Page 20
2002 Dimensi on One Spas Export Ow ner ’s Manual Using the Scrolling Message Center Your Scrolling Message Center is the most advanced in th e industry and can virtually walk you through cust omizing your hot tub to your exact n eeds. To i nitiate the progra mming sequence at any time, push and hold the Program pad for 3 seconds. If, within 10 se[...]
-
Page 21
2002 Dimensi on One Spas Export Ow ner ’s Manual Pump Run Time After setting the number of f ilter cycles, the top line of the Digital D isp lay will read “SET PUMP RUN TIME”. Push the UP or DOWN pads to toggle between 30, 45 and 60 minutes. This s e ts th e le ngth of time the pump will r un when a jets pad is pushed. F o r example, if you c[...]
-
Page 22
2002 Dimensi on One Spas Export Ow ner ’s Manual Programming Unlock To unlock the Panel: The follo wing pads must be pushed within 3 seconds : 1. Push the ENTER pad . 2. Push the ENTER pad . 3. Push the Dimension One S pa s ICON (logo) pad. When the last pad is pushed all pads will be active. Control Pa nel Reset This function is used to complete[...]
-
Page 23
2002 Dimensi on One Spas Export Ow ner ’s Manual Control Function 2 2. JETS Pad Operates the jet pump a ssociated with the Massage Sequencer. Sta tus Light illuminates when pump is on . 3 3. SPEED Pad The SPEED pad is used to change the ti me betw een each step in all sequences. The default time is factory programmed for 5 second inte rvals. The [...]
-
Page 24
2002 Dimensi on One Spas Export Ow ner ’s Manual Massage Zone Description The Dimension One Spas Dynamic M a ssage S eque ncer lets you enjoy a wide variety of massage patterns on the most critical muscle groups of-your body. You can choose s i x au toma tic jetting seque nce s, with six different zones , for a completely personalized hydrotherap[...]
-
Page 25
2002 Dimensi on One Spas Export Ow ner ’s Manual Zone 6 This zone is designed to massage the feet. T here are tw o directional mini VCR jthat are water volume contro llable, interchangeable wit h rotat ing jets and provide a narrowly focused massage patter n . Operating the Dynamic Massag e Sequ encer 1. Push the JETS pad to turn on the spa pump.[...]
-
Page 26
2002 Dimensi on One Spas Export Ow ner ’s Manual 1. Location of Male Hose F it t ing Figure 9 Male Hose Fitting 4. Screw the hose bib onto the male f itting located at the bottom of the hot tub on the pedestal, Figure 9, to the lower left of the eq ui pment compartment. 5. Close the valve on the side of the hose bib and screw the cap onto the end[...]
-
Page 27
2002 Dimensi on One Spas Export Ow ner ’s Manual 8. Remove the filter and fill your hot t ub w ith a hose through the emp ty fi lt er compartment to a level of one to two inches above the bottom of the ti le l ine . 9. Remove the two ship ping bolts located on the front of the pump mount and ensure that the gate valves on the pump(s) are in the o[...]
-
Page 28
2002 Dimensi on One Spas Export Ow ner ’s Manual Routine Equipment Maintenance Draining Your Equipment Danger Risk of Accidental Drowning . Extreme caution m ust be exercised to prevent unauthori zed access by children. To avoid accident s, ensure that chi ldren ca nnot use this system unless they are supervised at all times. All models are gravi[...]
-
Page 29
2002 Dimensi on One Spas Export Ow ner ’s Manual Warning Do not attempt to remove the light housing cover without lowering the w a ter leve l below the light housing cover. Note Do not attempt to remove the light housing cover without the s pecia l tool. If you are no t able to locate it, contact th e Dime nsion One Spas’ Service Depar t ment t[...]
-
Page 30
2002 Dimensi on One Spas Export Ow ner ’s Manual Care for the Wood Spa Cabinet When properly cared for, the wood cabinet of your ho t t ub w ill maintain its beauty fo r many years. All woods react differently to the elements by e x pand ing and contrac ting. To protec t your bea utiful wood finis h, r e-stain it every 3-6 months with Dimensio n [...]
-
Page 31
2002 Dimensi on One Spas Export Ow ner ’s Manual 7. If your system has a Dynamic Jet Sequencer, please remove that access pa nel as well and loosen all unions on each of the sequencer valves. There are 6 sequence r valves, that m ean s that yo u will have to loosen 12 unions. 8. Tip the system onto one side. (The system will have som e water rema[...]
-
Page 32
2002 Dimensi on One Spas Export Ow ner ’s Manual Note When pouring antifreeze into the rear-mos t bleeder valve fitting, you may see antifr eeze pouring from one or both of the circul ation system return fittings. Danger DO NOT USE AUTOMOTIVE COOLING SYSTEM ANTIFREEZE IN YOUR SYSTEM. IT IS TOXIC AND HARMFUL TO HUMANS AND ANIMALS. CHECK WITH YOUR [...]
-
Page 33
2002 Dimensi on One Spas Export Ow ner ’s Manual Warranty Service Information Your hot tub warranty gives you specific co verage. Be sur e to read the enclosed warranty sheet carefully. The warranty does not cover problems arising from misuse , abuse , or neglect, and it does not cover problems caused by improper installation or “perceived” p[...]
-
Page 34
2002 Dimensi on One Spas Export Ow ner ’s Manual Glossary of Terms Term Definition Bleeder Valve A small valve used to relieve or expel air from th e spa’s plumbing or pump. Circulation Pump A pump that circula tes th e water in the spa continuously. Dry Firing Turning the heater element on when there is no water in the hea ter. Equipment Acces[...]
-
Page 35
2002 Dimensi on One Spas Export Ow ner ’s Manual Term Definition completely open during normal opera tio ns. Smart Heat (Available on Dimension One Spas only) Smart Hea t opti mizes heat recovery using the amperage that you have available. Along with computeriz ed load sharing, that automatically recogn izes the number of jet pumps in use, compar[...]
-
Page 36
2002 Dimensi on One Spas Export Ow ner ’s Manual Troubleshooting Guide Heating System Symptom Problem Corrective Action 1. Temperature setting is too low 1. Turn up the thermostat 2. Dirty filter 2. Clean filter Does not heat 3. Flow switch malfunctio n 3. Call for service 1. Temperature setting is to high 1. Turn down the thermostat Too hot 2. H[...]
-
Page 37
2002 Dimensi on One Spas Export Ow ner ’s Manual Water System Symptom Problem Corrective Action Pulsating jets Water level too low Fill with water to 1” (2.54 cm) to 2” (5.08 cm) above bottom of the tile line 1. Jets are turned off 1. Turn jets on by turn ing jet face clockwise 2. Diverter Valve turned 2. Turn the Diverter Valve cl ockwise or[...]
-
Page 38
2002 Dimensi on One Spas Export Ow ner ’s Manual 34[...]
-
Page 39
2002 Dimensi on One Spas Export Ow ner ’s Manual 35[...]
-
Page 40
2002 Dimensi on One Spas Export Ow ner ’s Manual 36[...]