Dimplex LI 11MER manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Dimplex LI 11MER, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dimplex LI 11MER one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Dimplex LI 11MER. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Dimplex LI 11MER should contain:
- informations concerning technical data of Dimplex LI 11MER
- name of the manufacturer and a year of construction of the Dimplex LI 11MER item
- rules of operation, control and maintenance of the Dimplex LI 11MER item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dimplex LI 11MER alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dimplex LI 11MER, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dimplex service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dimplex LI 11MER.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Dimplex LI 11MER item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    Rev ersible Luft/W asser- Wärmepumpe für Innenaufstellung LI 11MER Rev ersible Air-to-W ater Heat P ump for Indoor Installation P ompe à chaleur air-eau rév ersible pour installation intérieur e Montage- und Gebrauchsanw eisung Deutsch English Français Instruc tions d’installation et d’utilisation Installation and Opera ting Instruc tions[...]

  • Page 2

    www.dimplex.de E-1 English Table of contents 1 Please Read Immediately ........................................ .......................................... ..................... ...... E-2 1.1 Important Information: ............. ................... ................ .................... ................... ............... ........... ............ E-[...]

  • Page 3

    E-2 English 1 1 Please Read Immediately 1.1 Important Information: ATTENTION! The device is not suitable for ope ration with a frequency converter. ATTENTION! When transporting the heat pump, ensure t h a t i t i s n o t t i l t e d m o r e t h a n 45° (in any direction). ATTENTION! The heat pump and transport pallet are only joined by the pa ckin[...]

  • Page 4

    www.dimplex.de E-3 English 3.1 2 Purpose of the Heat Pump 2.1 Application The air-to-water heat pump is designed fo r use in existi ng or newly built heating systems. It is desi gned exclusiv ely for heatin g and cooli ng heating wa ter! In heating opera tion, the heat pump is suitable fo r mono energy and bivalent operation down to an external tem[...]

  • Page 5

    E-4 English 3.2 3.2 Switch Box The switch box is located in the heat pump. It can be swung out after removing the lowe r front cover and lo osening the fasteni ng screw located i n the upper right-hand corner. The switch box contai ns the supply conn ection termi nals, as well the power conta ctors, the soft start er unit and the heat pump manager.[...]

  • Page 6

    www.dimplex.de E-5 English 6.2 5S e t - U P 5.1 General Information The unit must be installed ind oors on a level, smooth and hori- zontal surface. The en tire base of the frame sho uld lie directly on the floor to ensure a g ood soundproof seal. I f this is not the cas e, additional soun d insulation mea sures may be necessary. If the device is i[...]

  • Page 7

    E-6 English 6.3 The values in parentheses are vali d fo r the LI 16TE 6.3 Heating System Connection The heating system connections on the heat pump have a 1¼" external t hread. Use a spanner to fi rmly grip t he transiti ons when connecting the heat pump. Before connecting the heating wat er system to th e heat pump, the heating sys tem must [...]

  • Page 8

    www.dimplex.de E-7 English 7.3 7 Start-UP 7.1 General Information To ensure that start-up is performed correct ly, it should only be carried out by an after-sales servic e technician au thorised by t he manufacturer. Thi s may be a cond it ion f or exten din g t he guaran- tee (see Warranty Service). St art-up should be carried out in heating opera[...]

  • Page 9

    E-8 English 8 8 Maintenance / Cleaning 8.1 Maintenance To protect th e paintwork, avoi d leaning or p utting object s on the device. External heat pump parts can be wiped wi th a damp cloth and domestic cleaner. ATTENTION! Never use clea ning agents containing sand, soda, acid or chlorid e as these can damage the surfaces. To prevent faults due to [...]

  • Page 10

    www.dimplex.de E-9 English 11 11 Device Information 1 Type and order code LI 11MER 2D e s i g n 2.1 Model Reversible 2.2 Degree of protection accor ding to EN 60 52 9 IP 21 2.3 Installation location Indoors 3 Per formance data 3.1 Operating temperature l imits: Heating water flow/return flow °C / °C Up to 58 / above 18 Cooling, flow °C +7 to +20[...]

  • Page 11

    www.dimplex.de A-I Anhang · Ap pendix · Annex es Anhang / Appendix / Annexes 1 Maßbild / Dimension Drawing / Schéma coté ............................................................................ A-II 2 Diagramme / Diagrams / Dia grammes .................................................... ................................... A-III 2.1 Heizbe[...]

  • Page 12

    A-II Anhang · Ap pendix · Annex es 1 1 Maßbild / Dimension Drawing / Schéma coté /XIWULFKWXQJ 'LUHFWLRQRIDLUIORZ 6HQVGpFRXOHPHQWDLU %HGLHQVHLWH 2SHUDWLQJVLGH &{WpGHFRPPDQGH /XIWULFKWXQJ 'LUHFWLRQRIDLUIORZ 6HQVGpFRXOHPHQWDLU [,QQHQJHZLQGH0[ [LQWHUQDOWKUHDG?[...]

  • Page 13

    www.dimplex.de A-III Anhang · Ap pendix · Annex es 2.1 2 Diagramme / Diagrams / Diagrammes 2.1 Heizbetrieb / Heating Operation / Mode chauffage +HL]OHLVWXQJLQ>N:@ +HDWLQJFDSDFLWLQ>N:@ 3XLVVDQFHGHFKDXIIDJHHQ>N:@ :DVVHUDXVWULWWVWHPSHUDWXULQ>&@ :DWHURXWOHWWHPSHUDWXUHLQ>&@ 7 H[...]

  • Page 14

    A-IV Anhang · Ap pendix · Annex es 2.2 2.2 Kühlbetrieb / Cooling Operat ion / Mode refroidissement 9 HUIOVVLJHU &RQGHQVHU &RQGHQVHXU .KOOHLVWXQJLQ>N:@ &RROLQJFDSDFLWLQ>N:@ 3XLVVDQFHGHUHIURLGLVVHPHQWHQ>N:@ :DVVHUDXVWULWWVWHPSHUDWXULQ>&@ :DWHURXWOHWWHPSHUDWXUHLQ>[...]

  • Page 15

    www.dimplex.de A-V Anhang · Ap pendix · Annex es 3.1 3 Stromlaufpläne / Cir cuit Diagrams / Schémas électriques 3.1 Steuerung Standardregler / Cont rol of the standard controller / Commande régu lateur standard[...]

  • Page 16

    A-VI Anhang · Ap pendix · Annex es 3.2 3.2 Steuerung Kühlregle r / Control of the cooling controller / Commande régulateur standard[...]

  • Page 17

    www.dimplex.de A-VII Anhang · Ap pendix · Annex es 3.3 3.3 Last / Load / Charge[...]

  • Page 18

    A-VIII Anhang · Ap pendix · Annex es 3.4 3.4 Anschlussplan Standardregler / Te rminal diagram for the standard controller / Schéma électri que du régulateur standard RGHURURX[...]

  • Page 19

    www.dimplex.de A-IX Anhang · Ap pendix · Annex es 3.5 3.5 Anschlussplan Kühlregler / Te rminal diagram for the cooling controller / Schéma électrique du régulateur refroidissement 7 HPSHU 7 HPS 7 HPS )HXFKWH +XPLGLW +XPLGLWp 7 HPSHU 7 HPS 7 HPS )HXFKWH +XPLGLW +XPLGLWp[...]

  • Page 20

    A-X Anhang · Ap pendix · Annex es 3.6 3.6 Legende / Legend / Lége nde A1 Drahtbrücke, muss eingelegt werden, wenn kein Sperrschütz vorhande n ist Wire jumper, must be inserted if no blocking con- tactor is fitted Le cavalier à fil doit être inséré en absence de dis- joncteur de blocage du fournisseur d' énergie. A2 Drahtbrücke, muss[...]

  • Page 21

    www.dimplex.de A-XI Anhang · Ap pendix · Annex es 4.1 4 Hydraulische Prinzipschem en / Hydraulic Plumbing Diagrams / Schémas hydrauliques 4.1 Darstellung / Schemati c View / Représentation[...]

  • Page 22

    A-XII Anhang · Ap pendix · Annex es 4.2 4.2 Legende / Legend / Lége nde Absperrventil Shutoff valve Robinet d’arrêt Überstromventil Overflow valve Vanne de trop-plein Sicherheitsventi lkombination Safety valve combination Groupe de valves de sécurité Umwälzpumpe Circulati ng pump Circulateur Ausdehnungsgefäß Expansion vessel Vase d´exp[...]

  • Page 23

    www.dimplex.de A-XIII Anhang · Ap pendix · Annex es 5 5 Konformitätserklärung / Declaration of Conformity / Déclaration de conformité[...]

  • Page 24

    Glen Dimplex Deutschl and GmbH Geschäftsbereich Di mplex Am Goldenen Feld 18 D-95326 Kulmbach Irrtümer und Änderungen vorbehalten. Subject to a lterations and errors. Sous réserve d’erreurs et modifications. +49 (0) 9221 709 565 www.dimplex.de[...]