Go to page of
Similar user manuals
-
Heat Pump
Dimplex LI 20TEL
27 pages 1.71 mb -
Heat Pump
Dimplex WI 9 TE
32 pages 3.21 mb -
Heat Pump
Dimplex LI 11MS
44 pages 1.89 mb -
Heat Pump
Dimplex LI 11TER plus
32 pages 2.44 mb -
Heat Pump
Dimplex SI 100TE
29 pages 2 mb -
Heat Pump
Dimplex SI 14TE
36 pages 4.92 mb -
Heat Pump
Dimplex LA 22PS
26 pages 1.5 mb -
Heat Pump
Dimplex LA 35TUR plus
32 pages 2.08 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of Dimplex SI 5MER, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dimplex SI 5MER one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Dimplex SI 5MER. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Dimplex SI 5MER should contain:
- informations concerning technical data of Dimplex SI 5MER
- name of the manufacturer and a year of construction of the Dimplex SI 5MER item
- rules of operation, control and maintenance of the Dimplex SI 5MER item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dimplex SI 5MER alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dimplex SI 5MER, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dimplex service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dimplex SI 5MER.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Dimplex SI 5MER item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
Sole/W asser- Wärmepumpe für Innenaufstellung SI 5MER SI 7MER SI 9MER SI 11MER Brine-to-W at er Heat P ump for Indoor Installation P ompe à chaleur eau gly colée-eau pour installation intérieur e Montage- und Gebrauchsanw eisung Deutsch English Français Instruc tions d’installation et d’utilisation Installation and Opera ting Instruc tion[...]
-
Page 2
www.dimplex.de E-1 English Table of contents 1 Please Read Immediately ........................................ ............................................................... ...... E-2 1.1 Important Information ....... .................... ................ ................... ................ .................... ..... ................. ...... E-[...]
-
Page 3
E-2 English 1 1 Please Read Immediately 1.1 Important Information ATTENTION! The heat pump is not secu red to the wooden pallet. ATTENTION! The heat pump must not be tilted more than 45° (in any direction) . ATTENTION! Do not use the holes in the panel assemblies for lifting the device! ATTENTION! Flush the heating system prio r to connecting the [...]
-
Page 4
www.dimplex.de E-3 English 3 2 Purpose of the Heat Pump 2.1 Application The brine-to-water heat pump is designed for use in existi ng or newly built heati ng systems. Brine is used as the hea t carrier in the heat source syst em. Borehole heat exchangers, ground heat collectors or similar systems can be used as the heat source. 2.2 Operating Princi[...]
-
Page 5
E-4 English 4 4 Accessories 4.1 Brine Circuit Manifold The brine circuit mani fold merges the individua l collector loops of the heat source system into a single main pipe which is con- nected to the heat pump . Integra ted ball val ves a ll ow the i ndi vid - ual brine circuits to be shut of f for de-aeration purposes. 5 Transport A lift truck is [...]
-
Page 6
www.dimplex.de E-5 English 7.4 7 Installation 7.1 General Information The following con nections need to be established on the heat pump: Flow and return f low of the bri ne system Flow and return f low of the heat ing system Power supp ly 7.2 Heating System Connection ATTENTION! Flush the heating system prio r to connecting the heat pu[...]
-
Page 7
E-6 English 8 8 Commissioning 8.1 General Information To ensure that start-up is performed correctly, it should only be carried out by an after-sales servic e technici an authorise d by the manufacturer. This ma y be a condi tion f or exten din g the guaran - tee (see Warrant y).Start-up should be carri ed out in heating op - eration . 8.2 Preparat[...]
-
Page 8
www.dimplex.de E-7 English 11 9 Maintenance and Cleaning 9.1 Maintenance The heat pump is maintenan ce-free. To prevent faults due to sediment in the heat exchangers, care must be t aken to ensure that no impurities ca n enter either the heat source sys tem or the heating system. I n the event that operatin g malfunctions due to contamination occur[...]
-
Page 9
E-8 English 12 12 Device Information 1 Type and order code SI 5MER SI 7MER SI 9MER SI 11MER 2D e s i g n 2.1 Model Reversible Reversible Reversible Reversible 2.2 Degree of protection according to EN 60 529 IP20 IP20 IP20 IP20 2.3 Installation location Indoors Indoors Indoo rs Indoors 3 Performanc e data 3.1 Operating temperature li mits: Heating w[...]
-
Page 10
A-I Anhang · Ap pendix · Annexes Anhang / Appendix / Annexes 1 Maßbilder / Dimension Drawings / Schémas cotés .............................................................. ..... A-II 1.1 Maßbild / Dimension Drawing / Sc héma coté ............... ................. ................... ................ .................. .... A-II 2 Diagramme[...]
-
Page 11
A-II Anhang · Ap pendix · Annexes 1 1 Maßbilder / Dimension Drawings / Schémas cotés 1.1 Maßbild / Dimension Drawing / Schéma coté :lUPHTXHOOH (LQJDQJLQ:3 ´ $XHQJHZLQGH +HDWVRXUFH +HDWSXPSLQOHW ´H[WHUQDOWKUHDG 6RXUFHGHFKDOHXU (QWUpHGDQVOD3 $& )LO[...]
-
Page 12
A-III Anhang · Ap pendix · Annexes 2.1 2 Diagramme / Diagrams / Diagrammes 2.1 Heizbetrieb / Heating oper ation / Mode chauffage SI 5MER ?[...]
-
Page 13
A-IV Anhang · Ap pendix · Annexes 2.2 2.2 Kühlbetrieb / Cooling operati on / Mode refroi dissement SI 5MER ?[...]
-
Page 14
A-V Anhang · Ap pendix · Annexes 2.3 2.3 Heizbetrieb / Heating oper ation / Mode chauffage SI 7MER [...]
-
Page 15
A-VI Anhang · Ap pendix · Annexes 2.4 2.4 Kühlbetrieb / Cooling operati on / Mode refroi dissement SI 7MER [...]
-
Page 16
A-VII Anhang · Ap pendix · Annexes 2.5 2.5 Heizbetrieb / Heating oper ation / Mode chauffage SI 9MER [...]
-
Page 17
A-VIII Anhang · Ap pendix · Annexes 2.6 2.6 Kühlbetrieb / Cooling operati on / Mode refroi dissement SI 9MER ?[...]
-
Page 18
A-IX Anhang · Ap pendix · Annexes 2.7 2.7 Heizbetrieb / Heating oper ation / Mode chauffage SI 11MER [...]
-
Page 19
A-X Anhang · Ap pendix · Annexes 2.8 2.8 Kühlbetrieb / Cooling operati on / Mode refroidissement SI 11MER ?[...]
-
Page 20
A-XI Anhang · Ap pendix · Annexes 3.1 3 Stromlaufpläne / Circuit Diagrams / Schémas électriques 3.1 Steuerung Standardregler / Contro l via the standa rd controller / Commande régu lateur standard 1HW]0DLQV5pVHDX[...]
-
Page 21
A-XII Anhang · Ap pendix · Annexes 3.2 3.2 Steuerung Kühlregler / Control via the cooling controller / Commande régulateur refroidissement :HJH8PVFKDOWYHQWLO )RXUZDUHYHUVLQJYDOYH 6RXSDSHGHFRPPXWDWLRQYRLHV[...]
-
Page 22
A-XIII Anhang · Ap pendix · Annexes 3.3 3.3 Last / Load / Charge 1HW]0DLQV5pVHDX[...]
-
Page 23
A-XIV Anhang · Ap pendix · Annexes 3.4 3.4 Anschlussplan Standardregler / Terminal diagram for standard controller / Schéma de branchement du régulateur standard 1HW]0DLQV5pVHDX 1HW]/DVW0DLQV/RDG5pVHDX&KDUJH RGHUÂRUÂRX +HL]VWDE ,PPHUVLRQKHDWHU &DUWRXFKHFKDXIIDQWH[...]
-
Page 24
A-XV Anhang · Ap pendix · Annexes 3.5 3.5 Anschlussplan Kühlregler / Termin al diagram for cooling controller / Schéma de branchement du ré gulateur de refroidis sement 7 HPSHU 7 HPS 7 HPS )HXFKWH +XPLGLW +XPLGLWp 7 HPSHU 7 HPS 7 HPS PD[6HQVRUHQ 0D[VHQVRUV FDSWHXUVPD[...]
-
Page 25
A-XVI Anhang · Ap pendix · Annexes 3.6 3.6 Legende / Legend / Légende A1 Drahtbrücke, muss eingelegt werden, wenn kein Sperrschütz vorhande n ist Wire jumper, must be inserted if no blocking c on- tactor is fitted Le cavalier à fil doit être inséré en absence de dis- joncteur de blocage du fournisseur d' énergie. A2 Drahtbrücke, mus[...]
-
Page 26
A-XVII Anhang · Ap pendix · Annexes 4.1 4 Hydraulisches Prinzips chema / Hydraulic Plumbing Diagram / Schéma hydraulique 4.1 Darstellung / Schemati c View / Représentation[...]
-
Page 27
A-XVIII Anhang · Ap pendix · Annexes 4.2 4.2 Legende / Legend / Légende Absperrventil Shutoff val ve Robinet d’arrêt Absperrventil mit Entwässerung Shutoff valve with drainage Robinet d’arrêt avec écoulement Sicherheitsventi l Saf ety valve Vanne de sécurité Umwälzpumpe Circulati ng pump Circulateur Ausdehnungsgefäß Expansion vessel[...]
-
Page 28
A-XIX Anhang · Ap pendix · Annexes 5 5 Konformitätserklärung / D e claration of Conformity / Déclaration de conformité[...]
-
Page 29
Glen Dimplex Deutschl and GmbH Geschäftsbereich Di mplex Am Goldenen Feld 18 D-95326 Kulmbach Irrtümer und Änderungen vorbehalten. Subject to a lterations and errors. Sous réserve d’erreurs et modifications. +49 (0) 9221 709 565 www.dimplex.de[...]