DMC 5 Wire Analog Resistive Touchscreen FST Series manual
- Read online or download the manual
- 13 pages
- 0.95 mb
Go to page of
Similar user manuals
-
Universal Remote
DMC TSC-34/RU
13 pages 9.06 mb -
Universal Remote
DMC TSC-40/IC
24 pages 8.47 mb -
Universal Remote
DMC TSC-35/RU
13 pages 0.57 mb -
Universal Remote
DMC TSC-34/U-L
12 pages 10.1 mb -
Universal Remote
DMC 5 Wire Analog Resistive Touchscreen FST Series
13 pages 0.95 mb -
Universal Remote
DMC Analog Resistive Touchscreen ATP/AST Series
13 pages 0.95 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of DMC 5 Wire Analog Resistive Touchscreen FST Series, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of DMC 5 Wire Analog Resistive Touchscreen FST Series one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of DMC 5 Wire Analog Resistive Touchscreen FST Series. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of DMC 5 Wire Analog Resistive Touchscreen FST Series should contain:
- informations concerning technical data of DMC 5 Wire Analog Resistive Touchscreen FST Series
- name of the manufacturer and a year of construction of the DMC 5 Wire Analog Resistive Touchscreen FST Series item
- rules of operation, control and maintenance of the DMC 5 Wire Analog Resistive Touchscreen FST Series item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of DMC 5 Wire Analog Resistive Touchscreen FST Series alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of DMC 5 Wire Analog Resistive Touchscreen FST Series, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the DMC service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of DMC 5 Wire Analog Resistive Touchscreen FST Series.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the DMC 5 Wire Analog Resistive Touchscreen FST Series item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
5 Wire Analog Resistive T ouchscreen FST Series Product S pecifications[...]
-
Page 2
DER-S0081A 2 Rev . 4.0 ©2005 - 201 1 DMC Co., Ltd. FST Series Product Specification s T able of Contents 1. Product Speci fications ................................................................................................... 3 1-1. Product Applic able ..........................................................................................[...]
-
Page 3
DER-S0081A 3 Rev . 4.0 ©2005 - 201 1 DMC Co., Ltd. FST Series Product Specification s 1. Product Specifications 1-1. Product Applicable § This specification is applied to the 5 wire analog resistive touchscreen: FST Series. 1-2. Structur e § Dimensions, structure, and shape ar e referred on the drawing attached. 1-3. Environment al S pecificatio[...]
-
Page 4
DER-S0081A 4 Rev . 4.0 ©2005 - 201 1 DMC Co., Ltd. FST Series Product Specification s 1-6. Appearance § Scratch, dust (W = width, L = length, D = average diam eter = (longest + shortest) /2) Item Wid th (mm) Length (mm) Accept able Numbers T otal 0.1 ≥ W>0.05 4 ≥ L 1pcs in φ 30mm 0.05 ≥ W>0.03 10 ≥ L 2pcs in φ 20mm Linear(Scratch/[...]
-
Page 5
DER-S0081A 5 Rev . 4.0 ©2005 - 201 1 DMC Co., Ltd. FST Series Product Specification s 2. T esting Regulation 2-1. T esting Regulation § If the regulation is not specif ied, the test is performed und er the supplier ’s regulation. § T ests are performed under the room temperature unless specified. The room temperature is referred a s follows: T[...]
-
Page 6
DER-S0081A 6 Rev . 4.0 ©2005 - 201 1 DMC Co., Ltd. FST Series Product Specification s 2-4. Electrical Characteristics § T erminal Resistance T est Condition: T op and bottom electrod es are measured at the terminal. Judgement: Must satisfy the specification. § Insulation Resi stance T est Neighboring T erminals: Measured by applying the ref eren[...]
-
Page 7
DER-S0081A 7 Rev . 4.0 ©2005 - 201 1 DMC Co., Ltd. FST Series Product Specification s 3. Reliability Condition 3-1. T emperature Conditi on § T emperature Condition T est Following test are performed in the c ond ition with no dew condensation: Cold T est: T ested after le aving the parts in -40°C ± 3°C for 240 hours and in the room temperatur[...]
-
Page 8
DER-S0081A 8 Rev . 4.0 ©2005 - 201 1 DMC Co., Ltd. FST Series Product Specification s 5. Handling Notes 5-1. Precautions § This product is intended for use in standard applic ations (computers, office automation, and other office equipment, industrial, communications, and measur em ent equipment, personal and hou sehold devices, etc.) Please avoi[...]
-
Page 9
DER-S0081A 9 Rev . 4.0 ©2005 - 201 1 DMC Co., Ltd. FST Series Product Specification s 5-5. Mounting Notes § Gap bet ween the Bezel and T ouchscr een A gap of approximately 0.5 mm is needed bet ween the bezel and the top electrode. It may ca use une xpected input if the gap is too narrow . § Cushion If a cushion is used between t he bezel and t h[...]
-
Page 10
DER-S0081A 10 Rev . 4.0 ©2005 - 201 1 DMC Co., Ltd. FST Series Product Specification s 6. W arranty 6-1. W arranty Period § The warranty period is limited to 3 years from the dat e of shipping. The warrant y for the initial defection such as appearance defection is limited to 1 month. § Any defected parts under proper us e will be examined by th[...]
-
Page 11
DER-S0081A 1 1 Rev . 4.0 ©2005 - 201 1 DMC Co., Ltd. FST Series Product Specification s 7. Revision history Rev1.0 (May 1 1, 2005) Initial release Rev1.1 (July 13, 2005) 4-1.Recommended Connector is chang ed RE-H052SD-1 130 to RE-H052S D-1 1 10. 6-1.W arranty Period is changed 5 years to 3 years. Rev2.0 (October 13, 2006) The specification it em n[...]
-
Page 12
DER-S0081A 12 Rev . 4.0 ©2005 - 201 1 DMC Co., Ltd. FST Series Product Specification s 6-6. RoHS Compliance: Description abou t RoHS compliance has been added.[...]
-
Page 13
DER-S0081A 13 Rev . 4.0 ©2005 - 201 1 DMC Co., Ltd. FST Series Product Specification s FST Series Product S pecifications Rev . 4.0, Augu st 25, 201 1 © 2005 - 2010 DMC Co., Ltd. This document can be freely distributed, but any alternation to this docum ent is prohibited. http://www .dmccoltd.com/english/ 9 th floor , Kanda Sento Buil ding, 1-2-4[...]