Go to page of
Similar user manuals
-
Home Security System
DMP Electronics Command Processor Panel
26 pages 1.13 mb -
Home Security System
DMP Electronics XR10
28 pages 0.1 mb -
Home Security System
DMP Electronics XR10
26 pages 1.13 mb -
Home Security System
DMP Electronics XR500
84 pages 3.12 mb -
Home Security System
DMP Electronics LT-0229 (5 97)
18 pages 1.06 mb -
Home Security System
DMP Electronics XR6A
18 pages 0.87 mb -
Home Security System
DMP Electronics XR200A
1 pages 0.66 mb -
Home Security System
DMP Electronics SCS-1R
31 pages 1.78 mb
A good user manual
The rules should oblige the seller to give the purchaser an operating instrucion of DMP Electronics XR20A, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of DMP Electronics XR20A one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of DMP Electronics XR20A. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of DMP Electronics XR20A should contain:
- informations concerning technical data of DMP Electronics XR20A
- name of the manufacturer and a year of construction of the DMP Electronics XR20A item
- rules of operation, control and maintenance of the DMP Electronics XR20A item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of DMP Electronics XR20A alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of DMP Electronics XR20A, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the DMP Electronics service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of DMP Electronics XR20A.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the DMP Electronics XR20A item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
LT-0464 (6/99) XR6A /XR10A /XR20A Command Processor TM Panels Installation Guide 6/10/26 Zone Burglar y/Fire/Access Control Panels with Built-in Communicator 2841 E. Industrial Drive Springfield, MO USA 65802-6310 A CN 087 480 279 : http://www. guardianalarms . net[...]
-
Page 2
MODEL XR6A/XR10A/XR20A COMMAND PROCESSOR TM INST ALLA TION GUIDE COMPLIANCE STATEMENT The DMP Model XR6A, XR10A, and XR20A systems have been tested and comply with the requirements of CISPR22 Class B Electromagnetic Emissions, ACA Technical Standard TS001-1997 Electrical Safety, AS/NZS 3260-1993 including amendments 1 to 4 Electrical Safety, and AC[...]
-
Page 3
T ABLE OF CONTENTS Section Page P anel Specifications ........................................................................................... 5 1.1 P o wer supply .................................................................................................... 5 1.2 Communication ..............................................................[...]
-
Page 4
T ABLE OF CONTENTS Section Page P owered Zone f or 2-Wire Smoke Detectors .................................................... 15 11.1 T erminals 25 and 26 ....................................................................................... 15 Annunciator Outputs ...................................................................................[...]
-
Page 5
Introduction XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products Panel Specifications 1.1 Power supply Transformer Input: 16.5 VAC 40VA or 16.5 VAC 20VA Standby Battery: 12 VDC 7.0Ah (40VA transformer charges up to 2 batteries) Auxiliary Output: 12 VDC at 500mA Bell Ou[...]
-
Page 6
Introduction XR6A/XR10A/XR20A Installation Guide Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Introduction 2.1 Description The DMP XR6A/XR10A/XR20A Command Processors are powerful 12 VDC burglary and fire communicator panels with battery backup. The XR10A/XR20A provide nine on-board burglary zones[...]
-
Page 7
Introduction XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products System Components 3.1 Description The DMP XR6A/XR10A/XR20A system is made up of an alarm panel with built in communicator, an enclosure, a 16.5 VAC transformer, and a 12 VDC 7.0 Ah battery. You can add up[...]
-
Page 8
Introduction XR6A/XR10A/XR20A Installation Guide Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Figure 1: XR6A/XR10A/XR20A wiring diagram Page 4 Ref er to t he Com mand Proc ess orT M Pa n el Progr am m ing an d I n stalla t ion G uides for a com plete descr i ption of pr ogram m i n g i nstructi on[...]
-
Page 9
Installation XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products Installation 4.1 Mounting the enclosure The metal enclosure must be mounted in a secure, dry place to protect the panel from damage due to tampering or the elements. It is not necessary to remove the PC b[...]
-
Page 10
Installation XR6A/XR10A/XR20A Installation Guide Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 4.2 Mounting keypads Security Command keypads have removable covers that allow you to easily mount the base to a wall or other flat surface using the screw holes provided on each corner. For mounting keyp[...]
-
Page 11
Installation XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products Secondary Power Supply 6.1 Battery terminals 3 and 4 Connect the black battery lead to terminal 4 on the panel and to the negative terminal of the battery. The negative terminal connects to the enclosure [...]
-
Page 12
Installation XR6A/XR10A/XR20A Installation Guide Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 XR6A/XR10A/XR20A STANDBY BATTERY POWER CALCULATIONS Standby Current Alarm Current Command Processor Panel 50mA ______ mA 50mA ______ mA Active Zones 1-9 Qty _____ x 1.6mA ______ mA Qty _____ x *2mA ______[...]
-
Page 13
Installation XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products Bell Output 7.1 Terminals 5 and 6 Nominal 12 VDC is supplied by terminal 5 on the panel to power alarm bells or horns. The output is rated for a maximum of 1.5 Amps with a 40VA transformer and 600mA with [...]
-
Page 14
Installation XR6A/XR10A/XR20A Installation Guide Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Burglary Zones 10.1 Description The XR10A/XR20A terminals 12 to 24 are the nine burglary zones. For programming purposes, the zone numbers are 1 to 9. The zone configurations on terminals 12 to 24 are des[...]
-
Page 15
Installation XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products Powered Zone for 2-Wire Smoke Detectors 11.1 Terminals 25 and 26 A resettable 2-wire Class B powered zone is provided on terminals 25 (positive) and 26 (negative) of the panel. For programming purposes, t[...]
-
Page 16
Installation XR6A/XR10A/XR20A Installation Guide Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Annunciator Outputs 12.1 Description The four annunciator outputs can be programmed to indicate the activity of the panel's zones or conditions occurring on the system. Annunciator outputs do not pro[...]
-
Page 17
Installation XR6A/XR10A/XR20A Installation Guide 2841 E. Industrial Drive Springfield, MO USA 65802-6310 800-641-4282 Digital Monitoring Products Reset Jumpers J16 14.1 Description There are two reset jumpers located at the top right of the panel's circuit board labeled RESET. Momentarily shorting these jumpers allows you to reset the micropro[...]
-
Page 18
Digital Monitoring Products 2841 E. Industrial Drive Springfield, MO 65802-6310 800-64104282[...]