Dometic ABSORPTION RMD 8501 manual

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

Go to page of

A good user manual

The rules should oblige the seller to give the purchaser an operating instrucion of Dometic ABSORPTION RMD 8501, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.

What is an instruction?

The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dometic ABSORPTION RMD 8501 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.

Unfortunately, only a few customers devote their time to read an instruction of Dometic ABSORPTION RMD 8501. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.

What should a perfect user manual contain?

First and foremost, an user manual of Dometic ABSORPTION RMD 8501 should contain:
- informations concerning technical data of Dometic ABSORPTION RMD 8501
- name of the manufacturer and a year of construction of the Dometic ABSORPTION RMD 8501 item
- rules of operation, control and maintenance of the Dometic ABSORPTION RMD 8501 item
- safety signs and mark certificates which confirm compatibility with appropriate standards

Why don't we read the manuals?

Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dometic ABSORPTION RMD 8501 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dometic ABSORPTION RMD 8501, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dometic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dometic ABSORPTION RMD 8501.

Why one should read the manuals?

It is mostly in the manuals where we will find the details concerning construction and possibility of the Dometic ABSORPTION RMD 8501 item, and its use of respective accessory, as well as information concerning all the functions and facilities.

After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.

Table of contents for the manual

  • Page 1

    T ype C40 / 110 822 6114 - 00 T .B. MBA 02/2009 English N 1 RMD 8501 RMD 8505 RMD 8551 RMD 8555 Installation Instructions Absorption Refrigerator for Recreation V ehicles[...]

  • Page 2

    © Dometic GmbH - 2009 - Subject to change - Printed in Germany 2 Dometic GmbH In der Steinwiese 16 D-57074 Siegen www .dometic.com[...]

  • Page 3

    1.0 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.2 Guide to these operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . .[...]

  • Page 4

    4 1.0 General On installation of the appliance, the technical and administrative regulations of the country in which the vehicle will first be used must be adhered to. Otherwise the r efrigerator must be installed as described in these instructions. In Europe, for example, gas appliances, cable routing, installation of gas cylinders, as well as app[...]

  • Page 5

    5 General 1.7 Declaration of Conformity Information INFORMA TION gives you supplementary and useful guidance when dealing with your refrige- rator . Environmental Tips ENVIRONMENT AL TIPS gives you useful gui- dance for saving energy and disposal of the appliance. CAUTION (used without the safety alert sym- bol) indicates a potentially hazardous si[...]

  • Page 6

    6 Safety instructions 2.0 Safety instructions This refrigerator is designed for installation in recr eation vehicles such as caravans or motorhomes. The appliance has been type- approval tested for this application in accor- dance with the EC Gas Directive. The refrigerator is to be used solely for storing foodstuffs. 2.1 Application accor ding to [...]

  • Page 7

    7 Description of model Fig. 1 Model number Product number Serial number Electrical rating details Gas pressur e 2 2 1 1 3 3 4 4 5 5 RM 8 5 0 1 1 5 D Refrigerator Mobile / Mobile Absorption Refrigerator 1 = manual ener gy selection, automatic igni- tion (MES) 5 = automatic and manual ener gy selection, automatic ignition (AES) Model range 4 = Width [...]

  • Page 8

    8 Description of model 3.3 T echnical data Model Dimensions Gross capacity Rating details Consumption * Net Ignition H x W x D (mm) with mains/battery electricity/gas weight Piezo Automat Depth incl. door freezer compartment over 24hrs Subject to technical changes. * Average consumption measur ed at an average ambient temperature of 25°C in pursua[...]

  • Page 9

    9 Installation 4.0 Installation instructions The unit and the e xhaust duct system must be in principle installed so that it is accessible f or maintenance work, can be easily installed and dismantled and remov ed from the vehicle wit− hout great eff or t. Installation and connection of the appliance must comply with the latest technical regulati[...]

  • Page 10

    10 Installation Another unfavourable method of rear installation is to install the air int ake and exhaust grilles (Fig. 9) at the side wall of the recreation vehicle. The air-heat recirculation is very restricted which means that heat exchangers (condenser , absor- ber) cannot be adequately cooled. The optional method of an additional air vent gri[...]

  • Page 11

    11 Installation Fig. 7 Fig. 8 Fig. 9 Fig. 10 The flexible sealing is pressed into the gr oove running around the housing. Pr ess the side pro- vided with the sealing knob firmly into the groo- ve. T ake care that the sealings uniformly abut the housing. The cavity in-between the outer vehicle wall and refrigerator is completely isolated fr om the v[...]

  • Page 12

    12 Installation Fig. 1 1 The ventilation grilles must have an open cross-section of at least 400 cm². This is achieved by using the Dometic LS300 absorber ventilation and air extraction system which has been tested and approved for this purpose. 4.2.1 Installation of roof exhaust R500 and lower ventilation grille LS300. 4.2.2 Installation of lower[...]

  • Page 13

    13 Installation Correct mounting of the lower ventilation grille facilitates access to the connections and functional parts during maintenance. 4.3 Installing the ventilation system Fig. 13 Cut two rectangles in the outer wall of the vehicle. 1 Fig. 14 Seal the mounting frame making it waterproof ( does not apply for mounting frames with integral s[...]

  • Page 14

    Fig. 26 14 Fig. 25 Insert winter cover . 5 The exhaust gas duct system must be made in such a manner as to achieve a complete extrac- tion of combustion products to the outside of living space. The flue gas is vented directly through the upper grille. Do not use any kind of aluminium flue pipe to lead the flue gas out. The T -piece (Fig. 26) must b[...]

  • Page 15

    15 The refrigerator must be installed draught-pr oof in a recess (also r efer to Section "4.1.3"). The measurements of the r ecess are stated in the table below . Push the appliance far enough into the recess until the fr ont edge of the refrigerator casing is aligned with the front of the r ecess. Allow a gap of 15-20 mm between the back[...]

  • Page 16

    16 Installation 4.7 Insert the decor panel Fig. 31 Fig. 32  Remove the lateral ledge (1) from the door (ledge is attached, not screwed).  Shift decor panel (2) aw ay from the door and inser t the new decor panel. Re−attach ledge (1) . Fig. 29 Decor panel with frame Frameless decor panel Fig. 30 Fig. 33 1 2 Decor panel dimensions : 300 +/- 1[...]

  • Page 17

    17 Installation  Observe the regulations stated in section 4.1.  This refrigerator is pro vided for installati on within liquid gas equipment in compli− ance with EN1949 and must be run e xclu− sively on liquid gas (pr opane , butane) (no natural gas, to wn gas).  A fixed, pre−set pressure regulator com− plying with EN 12864 m ust [...]

  • Page 18

    18 Installation Fig. 35  The electrical installation must be in accordance with the national regulations of the respective countries.  The connection cables m ust be routed in a way to pre vent contact with hot compo nents of the unit/burner or with sharp edges.  Changes to the internal electrical installa− tion or the connection of othe[...]

  • Page 19

    19 Installation 4.9.3 T erminal strip Contacts : A = Ground heating element DC B = Positive connection, heating element DC C = Ground electr onics D = Positive connection, electronics D+ = Alternator signal S+ = AES input signal from solar char ge regulator Fig. 36 2 2 1 1 For MES and AES it is compulsory to provide a permanent 12V DC supply at the[...]

  • Page 20

    20 Installation Fig. 39 Wiring diagram RMD8xx1 : 4.9.5 Wiring diagram For MES and AES it is compulsory to provide a permanent 12V DC supply at the terminals C/D (permanent voltage supply for functional electronics).[...]

  • Page 21

    21 Installation Wiring diagram RMD8xx5 : For MES and AES it is compulsory to provide a permanent 12V DC supply at the terminals C/D (permanent voltage supply for functional electronics). Fig. 40[...]

  • Page 22

    22 Einbau[...]

  • Page 23

    23 Einbau[...]

  • Page 24

    24 Dometic GmbH In der Steinwiese 16 D-57074 Siegen www .dometic.com[...]