The rules should oblige the seller to give the purchaser an operating instrucion of Dometic VN 770, along with an item. The lack of an instruction or false information given to customer shall constitute grounds to apply for a complaint because of nonconformity of goods with the contract. In accordance with the law, a customer can receive an instruction in non-paper form; lately graphic and electronic forms of the manuals, as well as instructional videos have been majorly used. A necessary precondition for this is the unmistakable, legible character of an instruction.
What is an instruction?
The term originates from the Latin word „instructio”, which means organizing. Therefore, in an instruction of Dometic VN 770 one could find a process description. An instruction's purpose is to teach, to ease the start-up and an item's use or performance of certain activities. An instruction is a compilation of information about an item/a service, it is a clue.
Unfortunately, only a few customers devote their time to read an instruction of Dometic VN 770. A good user manual introduces us to a number of additional functionalities of the purchased item, and also helps us to avoid the formation of most of the defects.
What should a perfect user manual contain?
First and foremost, an user manual of Dometic VN 770 should contain:
- informations concerning technical data of Dometic VN 770
- name of the manufacturer and a year of construction of the Dometic VN 770 item
- rules of operation, control and maintenance of the Dometic VN 770 item
- safety signs and mark certificates which confirm compatibility with appropriate standards
Why don't we read the manuals?
Usually it results from the lack of time and certainty about functionalities of purchased items. Unfortunately, networking and start-up of Dometic VN 770 alone are not enough. An instruction contains a number of clues concerning respective functionalities, safety rules, maintenance methods (what means should be used), eventual defects of Dometic VN 770, and methods of problem resolution. Eventually, when one still can't find the answer to his problems, he will be directed to the Dometic service. Lately animated manuals and instructional videos are quite popular among customers. These kinds of user manuals are effective; they assure that a customer will familiarize himself with the whole material, and won't skip complicated, technical information of Dometic VN 770.
Why one should read the manuals?
It is mostly in the manuals where we will find the details concerning construction and possibility of the Dometic VN 770 item, and its use of respective accessory, as well as information concerning all the functions and facilities.
After a successful purchase of an item one should find a moment and get to know with every part of an instruction. Currently the manuals are carefully prearranged and translated, so they could be fully understood by its users. The manuals will serve as an informational aid.
Table of contents for the manual
-
Page 1
ENGLISH Dometic Environmental Corporation Rev . 20071204 L-2485 REMOTE A UXIL IARY AIR COND ITION ING AND AIR DIST RIBUT ION S YSTEMS FOR V OL V O L -5 CHASSIS INST ALLA TION GUIDEL INES For V ol vo T ruck M odels VN 7 7 0, 7 80, 83 0, 880[...]
-
Page 2
COPYRIGHT © 2007 Dometic Corporation, All Rights Reserved. No part of this publication may be repr oduced, translated, stored in a retrieval system, or transmitted in any form or by any means electr onic, mechanical, photocopying, recording or otherwise without prior written consent by Dometic Environmental Corporation. Every precaution has been t[...]
-
Page 3
ENGLISH 3 V olvo L-5 A/C - Air Distribution System DOMETI C TRUCK REMO TE A UXIL IARY A C S YSTEMS FOR V OL V O L -5 CHASSIS CONTENTS INTRODUCTION 4 INST ALLING THE CONTROL 4 Required T ools 4 Installing the Qt Digital Display 4 Mounting the Power Logic Box 5 Routing Cables 6 INST ALLING THE RETURN AIR VENT 7 INST ALLING THE SUPPL Y AIR DISTRIBUTIO[...]
-
Page 4
ENGLISH V olvo L-5 A/C - Air Distribution System 4 The instructions that follow represent years of development of parts and procedures that make the system perform well and appear “factory-installed.” INTRO DUCTI ON INST ALL ING TH E CONT ROL Mount the contr ol in a place that provides the driver convenient access. An ideal location would be ne[...]
-
Page 5
ENGLISH 5 V olvo L-5 A/C - Air Distribution System Mounting the Power Logic Box The Power Logic Box (PLB) will be mounted under the rear , center portion of the bunk (see Figure 2). T o accomplish this, rst remove the carpeted panel at the rear of the bunk. It is held in place by “Christmas trees” at each corner . Remove the backing plate fr[...]
-
Page 6
ENGLISH V olvo L-5 A/C - Air Distribution System 6 onto the machine screws. Secure the box with four nuts and lockwashers. KEPS nuts are easiest to use. Routing Cables The box has several differ ent types of cables: • Wires enclosed in split loom • Flexible power cables • “Phone” type cables The “wires in split loom” will go toward th[...]
-
Page 7
ENGLISH 7 V olvo L-5 A/C - Air Distribution System INST ALL ING TH E RETU RN AI R VENT The supplied return air vent should be installed under the bunk in the side panel, either on the passenger or driver side. The passenger side is recommended as there is less chance that it will get blocked by objects in the luggage compartment, and it will also a[...]
-
Page 8
ENGLISH V olvo L-5 A/C - Air Distribution System 8 Figure 5. Location of installed ductwork Figure 6. Footwell removed[...]
-
Page 9
ENGLISH 9 V olvo L-5 A/C - Air Distribution System Figure 7. Removal of sensor . Figure 8a. Four inch hole cut in V olvo duct. Figure 8b. Installation of grill and ducting.[...]
-
Page 10
ENGLISH V olvo L-5 A/C - Air Distribution System 10 Locate the V4 RND BLACK 4" grill. Using two cable ties, secure the vanes so that they will not tur n. See Figure 8a and 8b. Use a length of the supplied weather stripping under the lip of the grill to pr event air from leaking after installation. Install the grill from the inside of the duct,[...]
-
Page 11
ENGLISH 11 V olvo L-5 A/C - Air Distribution System Figure 10. Preparing to install grills in footwell cover . Figure 11. Location of cut out for ductwork.[...]
-
Page 12
ENGLISH V olvo L-5 A/C - Air Distribution System 12 Figure 12a. T emplate for 4" duct for 10K unit 0 5 . 3 2.00 Cut with 3.5" holesaw Cut with reciprocating saw[...]
-
Page 13
ENGLISH 13 V olvo L-5 A/C - Air Distribution System 3.50 0 0 . 4 Drill with 4" hole saw Cut with reciprocating saw Figure 12b. T emplate for 6" duct for 14K unit[...]
-
Page 14
ENGLISH V olvo L-5 A/C - Air Distribution System 14 Installing the Plenum on the Front of the CHEB Using a ¼" nutdriver , remove the plastic 5" or 7" oval hose adaptor . Find the 4"x 6" (or 4"x4") distribution plenum. Install the weather stripping on the contact surfaces and place over the hole on the unit. Reins[...]
-
Page 15
ENGLISH 15 V olvo L-5 A/C - Air Distribution System • One inboar d on the CHEB at the cor ner nearest the rear of the truck • One on the front, outboard • One on the outboard near the air distribution plenum • One on the front of the CHEB, inboard (near the factory HV AC unit) Use the “edge of unit” line to situate one of the moun- ting[...]
-
Page 16
ENGLISH V olvo L-5 A/C - Air Distribution System 16 Be sure to get the face and the threads. Hand tighten the quick connect, making sure they thr ead correctly . Tighten with the correct wrenches (13/16", ¾", and 15/16"). Tighten to 10-12 ft-lbs. Note: Any hissing that is hear d during the tightening pr ocess, is caused by the tt[...]
-
Page 17
ENGLISH 17 V olvo L-5 A/C - Air Distribution System Figure 16. Condenser installed on mounting plate. INST ALL ING TH E COND ENSER The Dometic condenser may be installed either under or behind the sleeper . These installations (and the parts in the kit) are for an installation under neath the sleeper . If you plan on mounting the generator and/or g[...]
-
Page 18
ENGLISH V olvo L-5 A/C - Air Distribution System 18 ROUTI NG TH E REFR IGERAN T LINES AND CONDEN SER PO WER CABLE The refrigerant lines will pass over the exhaust pipe, then over top of the condenser mounting plate, and back ar ound to the quick connect. Connect the quick connects in the manner described previously . Secur e the refrigerant lines a[...]
-
Page 19
ENGLISH 19 V olvo L-5 A/C - Air Distribution System Figure 17. Heat shield installed. Figure 18. Routing of refrigerent lines[...]
-
Page 20
ENGLISH V olvo L-5 A/C - Air Distribution System 20 Figure 20. Routing of refrigerant lines. TESTI NG TH E INST ALL A TIO N Supply power to the power distribution panel with either shorepower or generator power . Look at the display panel and conrm that the display is lit up. Press the F AN button to activate the fan in manual mode. Check for ai[...]
-
Page 21
[...]
-
Page 22
[...]
-
Page 23
[...]
-
Page 24
Dometic Environmental Corporation P .O. BOX 15299 I RICHMOND, VA 23227 USA I 804-746-1313 I F AX 804-746-7248 www .DometicT ruck.com I sales@DometicT ruck.com UNITED STA TES & CANADA SERVICE ONL Y 8:00 AM to 5:00 PM Eastern Time For all other areas visit our website to nd your nearest distributor . L-2485 Rev . 20071204[...]